Fitting of calibration-free scanned-wavelength-modulation spectroscopy spectra for determination of gas properties and absorption lineshapes

被引:211
|
作者
Goldenstein, Christopher S. [1 ]
Strand, Christopher L. [1 ]
Schultz, Ian A. [1 ]
Sun, Kai [1 ]
Jeffries, Jay B. [1 ]
Hanson, Ronald K. [1 ]
机构
[1] Stanford Univ, Dept Mech Engn, High Temp Gasdynam Lab, Stanford, CA 94305 USA
关键词
DIODE-LASER ABSORPTION; FREQUENCY-MODULATION; H2O TRANSITIONS; LINE-SHAPES; WATER-VAPOR; TEMPERATURE; PRESSURE; PARAMETERS; SENSOR; SIGNALS;
D O I
10.1364/AO.53.000356
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The development and initial demonstration of a scanned-wavelength, first-harmonic-normalized, wavelength-modulation spectroscopy with nf detection (scanned-WMS-nf / 1f) strategy for calibration-free measurements of gas conditions are presented. In this technique, the nominal wavelength of a modulated tunable diode laser (TDL) is scanned over an absorption transition to measure the corresponding scanned-WMS-nf / 1f spectrum. Gas conditions are then inferred from least-squares fitting the simulated scanned-WMS-nf / 1f spectrumto the measured scanned-WMS-nf / 1f spectrum, in a manner that is analogous to widely used scanned-wavelength direct-absorption techniques. This scanned-WMS-nf / 1f technique does not require prior knowledge of the transition linewidth for determination of gas properties. Furthermore, this technique can be used with any higher harmonic (i.e., n > 1), modulation depth, and optical depth. Selection of the laser modulation index to maximize both signal strength and sensitivity to spectroscopic parameters (i.e., gas conditions), while mitigating distortion, is described. Last, this technique is demonstrated with two-color measurements in a well-characterized supersonic flow within the Stanford Expansion Tube. In this demonstration, two frequency-multiplexed telecommunication-grade TDLs near 1.4 mu m were scanned at 12.5 kHz (i.e., measurement repetition rate of 25 kHz) and modulated at 637.5 and 825 kHz to determine the gas temperature, pressure, H2O mole fraction, velocity, and absorption transition lineshape. Measurements are shown to agree within uncertainty (1%-5%) of expected values. (C) 2014 Optical Society of America
引用
收藏
页码:356 / 367
页数:12
相关论文
共 50 条
  • [21] Calibration-Free Wavelength Modulation Spectroscopy for Gas Properties Measuring Basedon 2nd and 4th Harmonics
    Wang Yi-hong
    Zhou Bin
    Zhao Rong
    Wang Bu-bin
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43 (02) : 368 - 373
  • [22] Calibration-free wavelength modulation spectroscopy based on even-order harmonics
    Wang, Yihong
    Zhou, Bin
    Liu, Chang
    OPTICS EXPRESS, 2021, 29 (17): : 26618 - 26633
  • [23] Simulation technique enabling calibration-free frequency-modulation spectroscopy measurements of gas conditions and lineshapes with modulation frequencies spanning kHz to GHz
    Goldenstein, Christopher S.
    Mathews, Garrett C.
    APPLIED OPTICS, 2020, 59 (05) : 1491 - 1500
  • [24] A Wide-Range and Calibration-Free Spectrometer Which Combines Wavelength Modulation and Direct Absorption Spectroscopy with Cavity Ringdown Spectroscopy
    Wang, Zhen
    Du, Yanjun
    Ding, Yanjun
    Peng, Zhimin
    SENSORS, 2020, 20 (03)
  • [25] Calibration-free heterodyne phase-sensitive dispersion spectroscopy: quantitative gas sensing and recovery of absorption spectra
    Ma, Liuhao
    Zhou, Chen
    Wang, Zhen
    Ren, Wei
    Wang, Yu
    OPTICS EXPRESS, 2024, 32 (21): : 37492 - 37515
  • [26] Tunable diode laser spectroscopy with wavelength modulation: A phasor decomposition method for calibration-free measurements of gas concentration and pressure
    McGettrick, Andrew James
    Duffin, Kevin
    Johnstone, Walter
    Stewart, Georgge
    Moodie, David G.
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2008, 26 (1-4) : 432 - 440
  • [27] Tunable Diode Laser Spectroscopy With Wavelength Modulation: Calibration-Free Measurement of Gas Compositions at Elevated Temperatures and Varying Pressure
    McGettrick, Andrew J.
    Johnstone, Walter
    Cunningham, Robert
    Black, John D.
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2009, 27 (15) : 3150 - 3161
  • [28] A scanned-wavelength-modulation absorption-spectroscopy sensor for temperature and H2O in low-pressure flames
    Smith, Colin H.
    Goldenstein, Christopher S.
    Hanson, Ronald K.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2014, 25 (11)
  • [29] Cascade integrator comb filter-aided calibration-free Wavelength Modulation Spectroscopy Tomography
    Xia, Jiangnan
    Enemali, Godwin
    Zhang, Rui
    Liu, Chang
    2022 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC 2022), 2022,
  • [30] Calibration-free wavelength-modulation spectroscopy based on a swiftly determined wavelength-modulation frequency response function of a DFB laser
    Zhao, Gang
    Tan, Wei
    Hou, Jiajia
    Qiu, Xiaodong
    Ma, Weiguang
    Li, Zhixin
    Dong, Lei
    Zhang, Lei
    Yin, Wangbao
    Xiao, Liantuan
    Axner, Ove
    Jia, Suotang
    OPTICS EXPRESS, 2016, 24 (02): : 1723 - 1733