HbA1c measurement in Germany: Is the quality sufficient for follow-up and diagnosis?

被引:20
|
作者
Heinemann, Lutz [1 ]
Kaiser, Patricia [1 ]
Freckmann, Guido [1 ]
Grote-Koska, Denis [1 ]
Kerner, Wolfgang [1 ]
Landgraf, Ruediger [1 ]
Merker, Ludwig [1 ]
Mueller, Ulrich Alfons [1 ]
Mueller-Wieland, Dirk [1 ]
Roth, Johannes [1 ]
Spannagl, Michael [1 ]
Wallaschofski, Henri [1 ]
Nauck, Matthias [1 ]
机构
[1] Sci & Co, Kehler Str 24, D-40468 Dusseldorf, Germany
关键词
HbA(1c); quality control; EQA scheme; sample material; HEMOGLOBIN A(1C); DIABETES-MELLITUS; CLASSIFICATION; COMPLICATIONS; POINT; HBA1C;
D O I
10.1055/s-0043-125187
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Measurement of the HbA(1c) value represents an essential laboratory measure for the follow-up and therapy decision in patients with diabetes. High demands on the measurement quality of the measured variable can already be derived from the use of the HbA1c value for them. The use for diagnostic purposes requires even more for the monitoring explicit high analytical accuracy and precision. The HbA(1c) is one of the parameters in laboratory medicine that can be evaluated according to the guidelines of the German Medical Association (Rili-BAEK) in external quality control using the reference method value. The allowed deviation of +/- 18 % in external quality assessment (EQA) schemes and +/- 10 % in internal quality control has been ultimately met by virtually all the different manufacturers and methods. However, these broad limits for permissible deviations and the previously frequent/common use of EQA scheme materials that are not equally suitable for all systems, resulted in the fact that in HbA(1c) analytics inaccurately measured values or incorrectly calibrated devices are difficult to identify in Germany. With the implementation of unprocessed fresh EDTA blood, the situation has changed. This inter-laboratory material resembles patient blood as possible. Artificial matrix effects are thereby largely avoided. In the interests of high transparency, the POCT systems for HbA1c measurement in Germany should also participate in EQA scheme and all data should be made public. There is also the objective of aligning the requirements for quality criteria with international standards. This position paper out-lines the need to narrow the acceptance limits for HbA(1c) 's internal (to +/- 3 %) and external (to +/- 8 %) quality controls in Rili-BAEK. Higher quality in HbA(1c) measurements should avoid misdiagnosis of diabetes as well as potentially wrong and partially dangerous therapeutic consequences. What is technically feasible and market considerations must not play a role against medical requirements. In this context, an improvement in the communication of all participants by establishing a "Round Table HbA(1c)" is encouraged. Similarly, the involvement of the International and European medical associations in the field of diabetology (ADA/EASD) and clinical chemistry (IFCC) in the topic of HbA(1c) measurement should be strengthened.
引用
收藏
页码:46 / 53
页数:8
相关论文
共 50 条
  • [1] Higher HbA1c Measurement Quality Standards are Needed for Follow-Up and Diagnosis: Experience and Analyses from Germany (vol
    Heinemann, Lutz
    Kaiser, Patricia
    Freckmann, Guido
    Mueller, Ulrich A.
    [J]. HORMONE AND METABOLIC RESEARCH, 2018, 50 (10) : E5 - E5
  • [2] HbA1c measurement for the diagnosis of diabetes: is it enough?
    Cavagnolli, G.
    Comerlato, J.
    Comerlato, C.
    Renz, P. B.
    Gross, J. L.
    Camargo, J. L.
    [J]. DIABETIC MEDICINE, 2011, 28 (01) : 31 - 35
  • [3] HBA1C MEASUREMENT FOR THE DIAGNOSIS OF DIABETES: IS IT ENOUGH?
    Cosma, C.
    Lapolla, A.
    Epifani, M. G.
    Artusi, C.
    Zaninotto, M.
    Plebani, M.
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 : S375 - S375
  • [4] Structured Outpatient Diabetes Education and Telehealth Follow-up to Improve HbA1c
    Harris-Hardaway, Marina B.
    Novotny, Nancy L.
    Sawyer, Jennifer Dana
    Schmitt, Erin
    [J]. JOURNAL OF NURSING CARE QUALITY, 2023, 38 (03) : 220 - 225
  • [5] Changes in glucose and HbA1c prior to the diagnosis of diabetes: a 10-year follow-up of the Hoorn Study
    Van't Riet, E.
    Alssema, M.
    Teerlink, T.
    Nijpels, G.
    Stehouwer, C. D. A.
    Dekker, J. M.
    [J]. DIABETOLOGIA, 2011, 54 : S144 - S144
  • [6] HbA1c measurement
    Kilpatrick, ES
    [J]. JOURNAL OF CLINICAL PATHOLOGY, 2004, 57 (04) : 344 - 345
  • [7] Progressive worsening of HbA1c in 10 years of follow-up in type 2 diabetes
    Fornengo, P
    Bruno, A
    Ferrero, L
    Pagano, G
    [J]. DIABETOLOGIA, 1999, 42 : A106 - A106
  • [8] Quality of HbA1c Measurement in Practice - a Neglected Topic?
    Heinemann, L.
    Freckmann, G.
    [J]. DIABETES STOFFWECHSEL UND HERZ, 2014, 23 (02): : 91 - 98
  • [9] Ambulatory HbA1c determination is cost-effective in the follow-up of type 1 diabetic patients
    Ampudia-Blasco, F. J.
    Girbes, J.
    Catala, M.
    Carmena, R.
    [J]. DIABETOLOGIA, 2006, 49 : 539 - 539
  • [10] Diagnosis and Screening for HbA1c
    不详
    [J]. WEST INDIAN MEDICAL JOURNAL, 2009, 58 : 26 - 26