Higher HbA1c Measurement Quality Standards are Needed for Follow-Up and Diagnosis: Experience and Analyses from Germany

被引:19
|
作者
Heinemann, Lutz [1 ]
Kaiser, Patricia [2 ]
Freckmann, Guido [3 ]
Grote-Koska, Denis [4 ]
Kerner, Wolfgang [5 ]
Landgraf, Ruediger [6 ]
Merker, Ludwig [7 ]
Mueller, Ulrich A. [8 ]
Mueller-Wieland, Dirk [9 ]
Roth, Johannes [8 ]
Spannagl, Michael [2 ]
Wallaschofski, Henri
Nauck, Matthias [10 ,11 ]
机构
[1] Sci Consulting Diabet GmbH, Neuss, Germany
[2] Instand, Dusseldorf, Germany
[3] Inst Diabet Technol, Ulm, Germany
[4] Hannover Med Sch MHH, Inst Clin Chem, Hannover, Germany
[5] Klinikum Karlsburg, Dept Diabet & Metab, Karlsburg, Germany
[6] German Diabet Fdn, Munich, Germany
[7] Diabet & Nierenzentrum Dormagen, Dormagen, Germany
[8] Jena Univ Hosp, Endocrinol & Diabet, Dept Internal Med 3, Jena, Germany
[9] Univ Hosp Aachen, Dept Med 1, Aachen, Germany
[10] Univ Med Greifswald, Inst Clin Chem & Lab Med, Greifswald, Germany
[11] German Ctr Cardiovasc Res DZHK eV, Partner Site Greifswald, Greifswald, Germany
关键词
HbA1c; quality control; external quality assessment scheme; sample material; DIABETES-MELLITUS; HEMOGLOBIN A(1C); HBA(1C); CLASSIFICATION; COMPLICATIONS; POINT;
D O I
10.1055/a-0721-2273
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Measurement of HbA1c is an essential laboratory measure for the follow-up and therapy decision-making in patients with diabetes. HbA1c is one of the measurands in laboratory medicine that have to be successfully checked according to the criteria of the guidelines of the German Medical Association (Rili-BAEK) in external quality assurance using the reference method value concept, when applied in patient care. The allowed deviation of +/- 18 % in external quality assessment (EQA) and +/- 10 % in internal quality control has been ultimately met by virtually all the different manufacturers and methods. However, such broad limits for permissible deviations are not suitable in view of medical requirements in patient care. The low-level acceptance criteria also depends on the previously used EQA materials used in Germany. In fact, HbA1c measurement results that are imprecisely measured or come from incorrectly calibrated devices are difficult to identify. With implementation of unprocessed fresh EDTA blood, the situation has changed. Until now systems with unit use reagents for point-of-care testing (POCT) of HbA1c are not mandatory to participate in EQA schemes in Germany. This paper outlines why there was a need to narrow the acceptance limits listed within the Rili-BAEK for HbA1c's internal (to +/- 3 %) and external (to +/- 8 %) quality controls in EQA schemes for Germany, which will take place after a transition period in the next years. Higher quality in HbA1c measurements will help to avoid misdiagnosis of diabetes as well as potential over- or undertreatment of patients at risk for diabetes.
引用
收藏
页码:728 / 734
页数:7
相关论文
共 50 条
  • [1] HbA1c measurement in Germany: Is the quality sufficient for follow-up and diagnosis?
    Heinemann, Lutz
    Kaiser, Patricia
    Freckmann, Guido
    Grote-Koska, Denis
    Kerner, Wolfgang
    Landgraf, Ruediger
    Merker, Ludwig
    Mueller, Ulrich Alfons
    Mueller-Wieland, Dirk
    Roth, Johannes
    Spannagl, Michael
    Wallaschofski, Henri
    Nauck, Matthias
    DIABETOLOGIE UND STOFFWECHSEL, 2018, 13 (01) : 46 - 53
  • [2] HbA1c measurement for the diagnosis of diabetes: is it enough?
    Cavagnolli, G.
    Comerlato, J.
    Comerlato, C.
    Renz, P. B.
    Gross, J. L.
    Camargo, J. L.
    DIABETIC MEDICINE, 2011, 28 (01) : 31 - 35
  • [3] HBA1C MEASUREMENT FOR THE DIAGNOSIS OF DIABETES: IS IT ENOUGH?
    Cosma, C.
    Lapolla, A.
    Epifani, M. G.
    Artusi, C.
    Zaninotto, M.
    Plebani, M.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 : S375 - S375
  • [4] Structured Outpatient Diabetes Education and Telehealth Follow-up to Improve HbA1c
    Harris-Hardaway, Marina B.
    Novotny, Nancy L.
    Sawyer, Jennifer Dana
    Schmitt, Erin
    JOURNAL OF NURSING CARE QUALITY, 2023, 38 (03) : 220 - 225
  • [5] Changes in glucose and HbA1c prior to the diagnosis of diabetes: a 10-year follow-up of the Hoorn Study
    Van't Riet, E.
    Alssema, M.
    Teerlink, T.
    Nijpels, G.
    Stehouwer, C. D. A.
    Dekker, J. M.
    DIABETOLOGIA, 2011, 54 : S144 - S144
  • [6] Progressive worsening of HbA1c in 10 years of follow-up in type 2 diabetes
    Fornengo, P
    Bruno, A
    Ferrero, L
    Pagano, G
    DIABETOLOGIA, 1999, 42 : A106 - A106
  • [7] Quality of HbA1c Measurement in Practice - a Neglected Topic?
    Heinemann, L.
    Freckmann, G.
    DIABETES STOFFWECHSEL UND HERZ, 2014, 23 (02): : 91 - 98
  • [8] Hba1c: From standardisation to use in diagnosis
    Miedema, K
    CLINICA CHIMICA ACTA, 2005, 355 : S40 - S40
  • [9] Ambulatory HbA1c determination is cost-effective in the follow-up of type 1 diabetic patients
    Ampudia-Blasco, F. J.
    Girbes, J.
    Catala, M.
    Carmena, R.
    DIABETOLOGIA, 2006, 49 : 539 - 539
  • [10] Comparison of Fasting Plasma Glucose and HbA1c for Follow-up of Women with Previous Gestational Diabetes
    Noctor, E.
    Crowe, C.
    Avalos, G.
    Carmody, L.
    Wickham, B.
    O' Shea, P.
    Gaffney, G.
    Dunne, F.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2012, 181 : S350 - S350