Torque Ripple Minimization of a Five-Phase Induction Motor Under Open-Phase Faults Using Symmetrical Components

被引:11
|
作者
He, Shan [1 ]
Sui, Xin [1 ]
Liu, Zijian [2 ]
Kang, Min [3 ]
Zhou, Dao [1 ]
Blaabjerg, Frede [1 ]
机构
[1] Aalborg Univ, Dept Energy Technol, DK-9220 Aalborg, Denmark
[2] Tsinghua Univ, Dept Elect Engn, Beijing 100084, Peoples R China
[3] Zhejiang Univ Sci & Technol, Coll Elect Engn, Hangzhou 310023, Peoples R China
来源
IEEE ACCESS | 2020年 / 8卷 / 08期
基金
中国国家自然科学基金;
关键词
Torque measurement; Harmonic analysis; Circuit faults; Torque; Stators; Induction motors; Steady-state; Five-phase induction motor; fault-tolerant operation; minimum torque ripple; symmetrical component; POSTFAULT OPERATION; DRIVE SYSTEM; MACHINE; DESIGN; SINGLE;
D O I
10.1109/ACCESS.2020.2998867
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In order to minimize the torque ripple of five-phase induction motor under open-phase faults, the conventional strategy makes the stator current space vectors to move along the circular anticlockwise trajectories. However, the torque ripple is suppressed indirectly based on the coupling between spatial harmonic fields, and the analytical expression of the torque ripple is not considered. In this paper, according to the steady-state model using symmetrical components (SCs), the torque ripple is mainly caused by the first and fourth SCs. Hence, several possible current commands are deduced under single-phase fault and two-phase fault by suppressing the first and fourth SCs. Under single-phase fault, the proposed strategy shows better performance than the conventional strategy in terms of torque ripple, average torque and efficiency. Under adjacent two-phase fault, the proposed strategy shows lower torque ripple but a lower efficiency than the conventional strategy, and these two strategies can be selected according to the specific application requirements. Finally, the effectiveness of the proposed strategy is validated by the experimental results.
引用
收藏
页码:114675 / 114691
页数:17
相关论文
共 50 条
  • [41] Sensorless Direct Torque Control of Five-Phase Induction Motor Drives
    Khaldi, B. S.
    Abu-Rub, H.
    Iqbal, A.
    Kennel, R.
    Mahmoudi, M. O.
    Boukhetala, D.
    IECON 2011: 37TH ANNUAL CONFERENCE ON IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2011,
  • [42] An Improved DTC Based Five-phase Induction Motor Drive with Minimum Torque Ripple and Constant Switching Frequency
    Gauri, Anitha
    Vinod, Balachandran Remabai
    Sreeni, Kamalalayam Gopalan
    Shiny, Gopinathan
    ADVANCES IN ELECTRICAL AND COMPUTER ENGINEERING, 2024, 24 (01) : 51 - 60
  • [43] Torque Ripple Reduction in Direct Torque Control of Five-Phase Induction Motor Using Fuzzy Controller with Optimized Voltage Vector Selection Strategy
    Shin, Hye Ung
    Kang, Seong Yun
    Lee, Kyo-Beum
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2017, 12 (03) : 1177 - 1186
  • [44] A Comprehensive Fault Analysis of a Five-Phase Induction Motor Drive with an Open Phase
    Guzman, H.
    Duran, M. J.
    Barrero, F.
    2012 15TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE (EPE/PEMC), 2012,
  • [45] A novel DTC scheme for a sensorless five-phase IM drive under open-phase fault
    Echeikh, Hamdi
    Kesraoui, Hichem
    Trabelsi, Ramzi
    Iqbal, Atif
    Mimouni, Mohamed Faouzi
    COMPEL-THE INTERNATIONAL JOURNAL FOR COMPUTATION AND MATHEMATICS IN ELECTRICAL AND ELECTRONIC ENGINEERING, 2019, 38 (02) : 829 - 844
  • [46] Performance of a Three-to-Five Matrix Converter Fed Five-Phase Induction Motor under Open-Circuit Switch Faults
    Dabour, Sherif M.
    Abdel-khalik, Ayman
    Ahmed, Shehab
    Massoud, Ahmed
    2016 IEEE SYMPOSIUM ON COMPUTER APPLICATIONS & INDUSTRIAL ELECTRONICS (ISCAIE), 2016, : 159 - 164
  • [47] Sensorless Field Oriented Control of Five-phase Induction Machine Under Open-Circuit Phase Faults
    Morsy, Ahmed S.
    Abdel-khalik, A. S.
    Ahmed, Shehab
    Massoud, Ahmed
    2013 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2013, : 5112 - 5117
  • [48] Comparative Study of Hysteresis Controller, Resonant Controller and Direct Torque Control of Five-Phase IM under Open-Phase Fault Operation
    A. Mossa, Mahmoud
    Echeikh, Hamdi
    Diab, Ahmed A. Zaki
    Haes Alhelou, Hassan
    Siano, Pierluigi
    ENERGIES, 2021, 14 (05)
  • [49] Fault-Tolerant Control of Five-Phase Induction Motor Under Single-Phase Open
    Kong, Wubin
    Huang, Jin
    Kang, Min
    Li, Bingnan
    Zhao, Lihang
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2014, 9 (03) : 899 - 907
  • [50] Diagnosis of open-phase fault of five-phase permanent magnet synchronous motor by harmonic current analysis
    Li, Tianxing
    Ma, Ruiqing
    Zhang, Zhen
    MICROELECTRONICS RELIABILITY, 2021, 126