Prolonged irradiation of enhanced cyan fluorescent protein or Cerulean can invalidate Forster resonance energy transfer measurements

被引:22
|
作者
Hoffmann, Birgit [1 ]
Zimmer, Thomas [1 ]
Kloecker, Nikolai [3 ]
Kelbauskas, Laimonas [1 ]
Koenig, Karsten [2 ]
Benndorf, Klaus [1 ]
Biskup, Christoph [1 ]
机构
[1] Univ Klinikum Jena, Inst Physiol 2, D-07740 Jena, Germany
[2] Univ Saarland, Fac Phys & Mechtron, D-66123 Saarbrucken, Germany
[3] Univ Freiburg, Inst Physiol, D-79104 Freiburg, Germany
关键词
enhanced cyan fluorescent protein; Cerulean; time-resolved spectroscopy; streak camera; Forster resonance energy transfer; fluorescence resonance energy transfer; fluorescence lifetime imaging; photobleaching; photoconversion;
D O I
10.1117/1.2937829
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Since its discovery, green fluorescent protein (GFP) and its variants have proven to be a good and convenient fluorescent label for proteins: GFP and other visible fluorescent proteins (VFPs) can be fused selectively to the protein of interest by simple cloning techniques and develop fluorescence without additional cofactors. Among the steadily growing collection of VFPs, several pairs can be chosen that can serve as donor and acceptor fluorophores in Forster resonance energy transfer (FRET) experiments. Among them, the cyan fluorescent proteins (ECFP/Cerulean) and the enhanced yellow fluorescent protein (EYFP) are most commonly used. We show that ECFP and Cerulean have some disadvantages despite their common use: Upon irradiation with light intensities that are commonly used for intensity- and lifetime-based FRET measurements, both the fluorescence intensity and the fluorescence lifetime of ECFP and Cerulean decrease. This can hamper both intensity- and lifetime-based FRET measurements and emphasizes the need for control measurements to exclude these artifacts. (c) 2008 Society of Photo-Optical Instrumentation Engineers.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Linear Approaches to Intramolecular Forster Resonance Energy Transfer Probe Measurements for Quantitative Modeling
    Birtwistle, Marc R.
    von Kriegsheim, Alexander
    Kida, Katarzyna
    Schwarz, Juliane P.
    Anderson, Kurt I.
    Kolch, Walter
    PLOS ONE, 2011, 6 (11):
  • [42] Surface plasmon enhanced Forster resonance energy transfer between the CdTe quantum dots
    Komarala, Vamsi K.
    Bradley, A. Louise
    Rakovich, Yury P.
    Byrne, Stephen J.
    Gun'ko, Yurii K.
    Rogach, Andrey L.
    APPLIED PHYSICS LETTERS, 2008, 93 (12)
  • [43] On the concentration dependence of metallic nano-particles in enhanced Forster resonance energy transfer
    Hoa, N. M.
    Nhung, T. H.
    Thao, T. T.
    Theu, L. T.
    Viet, N. A.
    41ST VIETNAM NATIONAL CONFERENCE ON THEORETICAL PHYSICS, 2017, 865
  • [44] Detection of Protein Interactions in the Cytoplasm and Periplasm of Escherichia coli by Forster Resonance Energy Transfer
    Meiresonne, Nils Y.
    Alexeevasa, Svetlana
    van der Ploeg, Rend
    den Blaauwen, Tanneke
    BIO-PROTOCOL, 2018, 8 (02):
  • [45] Measuring Large Membrane Protein Dimerization in Lipid Bilayers by Forster Resonance Energy Transfer
    Krishnamani, Venkatramanan
    Mersch, Kacey
    Chadda, Rahul
    Chadda, Ankita
    Robertson, Janice L.
    BIOPHYSICAL JOURNAL, 2016, 110 (03) : 228A - 228A
  • [46] Fluorescent material concentration dependency: Forster resonance energy transfer in quasi-solid state DSSCs
    Kim, Dong Woo
    Jo, Hyun-Jun
    Thogiti, Suresh
    Yang, Weon Ki
    Cheruku, Rajesh
    Kim, Jae Hong
    ELECTRONIC MATERIALS LETTERS, 2017, 13 (03) : 249 - 254
  • [47] Electrospinning: A facile method to disperse fluorescent quantum dots in nanofibers without Forster resonance energy transfer
    Li, Minjie
    Zhang, Junhu
    Zhang, Hao
    Liu, Yifei
    Wang, Chunlei
    Xu, Xiang
    Tang, Yue
    Yang, Bai
    ADVANCED FUNCTIONAL MATERIALS, 2007, 17 (17) : 3650 - 3656
  • [48] Forster Resonance Energy Transfer-Based Fluorescent Probe for the Selective Imaging of Hydroxylamine in Living Cells
    Dong, Baoli
    Tian, Minggang
    Kong, Xiuqi
    Song, Wenhui
    Lu, Yaru
    Lin, Weiying
    ANALYTICAL CHEMISTRY, 2019, 91 (17) : 11397 - 11402
  • [49] Forster Resonance Energy Transfer between Fluorescent Proteins: Efficient Transition Charge-Based Study
    Kitoh-Nishioka, Hirotaka
    Yokogawa, Daisuke
    Irle, Stephan
    JOURNAL OF PHYSICAL CHEMISTRY C, 2017, 121 (08): : 4220 - 4238
  • [50] Combining MFD and PIE for Accurate Single-Pair Forster Resonance Energy Transfer Measurements
    Kudryavtsev, Volodymyr
    Sikor, Martin
    Kalinin, Stanislav
    Mokranjac, Dejana
    Seidel, Claus A. M.
    Lamb, Don C.
    CHEMPHYSCHEM, 2012, 13 (04) : 1060 - 1078