Rapid single-step method for flow cytometric detection of surface and intracellular antigens using whole blood

被引:0
|
作者
Francis, C [1 ]
Connelly, MC [1 ]
机构
[1] ORTHO DIAGNOST SYST INC,IMMUNOCYTOMETRY DEPT,RARITAN,NJ 08869
来源
CYTOMETRY | 1996年 / 25卷 / 01期
关键词
PermeaFix; flow cytometry; permeabilization; intracellular antigen; whole blood; immunophenotyping; light scatter;
D O I
10.1002/(SICI)1097-0320(19960901)25:1<58::AID-CYTO7>3.0.CO;2-A
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Fixation/permeabilization methods used for the detection of intracellular antigens by now cytometry often result ia the destruction of cellular morphology and surface immunoreactivity, properties useful in flow cytometry for the characterization of cells in heterogeneous populations. In addition, a majority of these methods are incompatible with whole blood and require that peripheral blood leukocytes (PBLs) be purified prior to fixation. This article describes a new technique for the rapid detection of both intracellular and cell surface antigens, while preserving cell morphology, through the use of a single-step fixation/permeabilization reagent, ORTHO PermeaFix (OFF). OFF is compatible with whole blood, allowing for the direct preparation of PBLs without prior cell separation. An additional red blood cell lysing reagent was not required because RBC lysis occurred upon resuspension of OFF-treated whole blood samples in isotonic solution. Discrimination of leukocyte populations by light scatter after OFF treatment was comparable to matched unfixed live cells. in addition, absolute lymphocyte and white blood cell (WBC) counts were not significantly affected when OFF-treated cells were compared with unfixed cells. Treatment of whole blood from 7 normal donors showed no significant difference in percentage of cells positive for CD2, CD3, CD4, CD8, CD16, or CD19 between fixed and unfixed samples when cells were stained before fixation, and no difference in CD3, CD4, CD8, CD16, or CD19 percentages when cells were stained following fixation. Monoclonal antibodies specific for intracellular antigens located at various sites within the cell were tested on fixed samples. OFF-treated peripheral blood lymphocytes showed greater than 95% reactivity for the inner mitochondrial membrane protein bcl-2, and the cytoskeletal cytoplasmic protein vimentin. TIA-1, a cytolytic granule-associated protein, showed differential reactivity within lymphocyte subsets, from a low of 8 +/- 2% in CD4(+) cells to 89 +/- 6% in CD16(+) cells, when whole blood from five normal donors was fixed and stained. Reh cells treated with OFF showed greater than 95% reactivity for the internuclear protein TdT. A comparison of OFF with two other fixation/permeabilization procedures, 1% paraformaldehyde followed by 45% ethanol and 0.25% paraformaldehyde followed by 0.2% Tween 20, showed that only OFF could be used both prior to or following cell surface staining with no effect on antigen detection while allowing optimal detection of all of the intracellular antigens tested. (C) 1996 Wiley-Liss, Inc.
引用
收藏
页码:58 / 70
页数:13
相关论文
共 50 条
  • [31] RAPID SINGLE-STEP METHOD FOR PURIFICATION OF POLYMORPHONUCLEAR LEUKOCYTES FROM BLOOD OF PATIENTS WITH RHEUMATOID-ARTHRITIS
    FERRANTE, A
    JAMES, DW
    BETTS, WH
    CLELAND, LG
    CLINICAL AND EXPERIMENTAL IMMUNOLOGY, 1982, 47 (03): : 749 - 752
  • [32] A new flow cytometric method for detection of BrdU incorporation and surface antigens: Determination of labeling indices in myeloma
    Schlenke, P
    Hammers, HJ
    Saballus, M
    Kirchner, H
    BONE MARROW TRANSPLANTATION, 1999, 23 : S139 - S139
  • [33] A flow cytometric method for the detection of intracellular basic proteins in unseparated peripheral blood and bone marrow eosinophils
    Krug, N
    Thurau, AM
    Lackie, P
    Baier, J
    SchultzeWerninghaus, G
    Rieger, CHL
    Schauer, U
    JOURNAL OF IMMUNOLOGICAL METHODS, 1996, 190 (02) : 245 - 254
  • [34] Single-step vertical plasma separation of whole blood for tests and sample prep
    Alter, J
    GENETIC ENGINEERING NEWS, 1996, 16 (20): : 30 - 30
  • [35] Combined Flow Cytometric Analysis of Surface and Intracellular Antigens Reveals Surface Molecule Markers of Human Neuropoiesis
    Turac, Gizem
    Hindley, Christopher J.
    Thomas, Ria
    Davis, Jason A.
    Deleidi, Michela
    Gasser, Thomas
    Karaoz, Erdal
    Pruszak, Jan
    PLOS ONE, 2013, 8 (06):
  • [36] Characterization of Surface Acetylated Nanocrystalline Cellulose by Single-Step Method
    Yan, Meiling
    Li, Shujun
    Zhang, Mingxin
    Li, Chunjie
    Dong, Feng
    Li, Wei
    BIORESOURCES, 2013, 8 (04): : 6330 - 6341
  • [37] Single-Step Method for the Isolation and Surface Functionalization of Cellulosic Nanowhiskers
    Braun, Birgit
    Dorgan, John R.
    BIOMACROMOLECULES, 2009, 10 (02) : 334 - 341
  • [38] A RAPID OBJECTIVE IMMUNOFLUORESCENCE MICROASSAY - APPLICATION FOR DETECTION OF SURFACE AND INTRACELLULAR ANTIGENS
    PITZURRA, L
    BLASI, E
    BARTOLI, A
    MARCONI, P
    BISTONI, F
    JOURNAL OF IMMUNOLOGICAL METHODS, 1990, 135 (1-2) : 71 - 75
  • [39] A simple method for the flow cytometric analysis of intracellular antigens in whole smooth muscle cells: Quantification of cyclin-dependent kinase 2
    Sindermann, J
    Weigel, KA
    Breithardt, G
    JOURNAL OF IMMUNOLOGICAL METHODS, 1997, 202 (02) : 205 - 212
  • [40] Single-step radiofluorination of peptides using continuous flow microreactor
    Selivanova, Svetlana V.
    Mu, Linjing
    Ungersboeck, Johanna
    Stellfeld, Timo
    Ametamey, Simon M.
    Schibli, Roger
    Wadsak, Wolfgang
    ORGANIC & BIOMOLECULAR CHEMISTRY, 2012, 10 (19) : 3871 - 3874