Determination of UV filters in high ionic strength sample solutions using matrix-compatible coatings for solid-phase microextraction

被引:21
|
作者
An, Jiwoo [1 ]
Anderson, Jared L. [1 ]
机构
[1] Iowa State Univ, Dept Chem, 1605 Gilman Hall, Ames, IA 50011 USA
基金
美国国家科学基金会;
关键词
Polymeric ionic liquids; Solid-phase microextraction; Double-confined polymer; Ultraviolet filters; High performance liquid chromatography; PERFORMANCE LIQUID-CHROMATOGRAPHY; TANDEM MASS-SPECTROMETRY; GAS-CHROMATOGRAPHY; ULTRAVIOLET FILTERS; SORBENT COATINGS; AQUEOUS SAMPLES; WATER SAMPLES; ANALYTICAL-CHEMISTRY; ASSISTED EXTRACTION; RAPID-DETERMINATION;
D O I
10.1016/j.talanta.2018.01.052
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A double-confined polymeric ionic liquid (PIL) sorbent coating was fabricated for the determination of nine ultraviolet (UV) filters in sample solutions containing high salt content by direct immersion solid-phase microextraction (DI-SPME) coupled to high-performance liquid chromatography (HPLC). The IL monomer and crosslinker cations and anions, namely, 1-vinyl-3-decylimidazolium styrenesulfonate ([VImC(10)] [SS]) and 1,12-di (3-vinylbenzylimidazolium) dodecane distyrenesulfonate ([(VBIm)(2)C-12] 2 [SS]), were co-polymerized to create a highly stable sorbent coating which allowed for up to 120 direct-immersion extractions in 25% NaCl (w/v) solution without a decrease in its extraction capability. Extraction and desorption parameters such as desorption solvent, agitation rate, extraction time, desorption solvent volume, and desorption time were evaluated and optimized. The analytical performance of the styrenesulfonate anion-based PIL fiber, PIL fiber containing chloride anions, and a commercially available polydimethylsiloxane/divinylbenzene (PDMS/DVB) fiber were compared. Coefficients of determination (R-2) for the styrenesulfonate anion-based PIL fiber ranged from 0.995 to 0.999 and the limits of detection (LODs) varied from 0.1 to 5 mu g L-1. The developed method was successfully applied in real water samples including tap, pool, and lake water, and acceptable relative recovery values were obtained. The lifetime of the PIL fiber containing chloride anions as well as the PDMS/DVB fiber were considerably shorter than the PIL fiber containing the styrenesulfonate anion, with both fibers showing a notable decrease in reproducibility and significant damage to the sorbent coating surface after 40 and 70 extractions, respectively. The R-2 values for the chloride anion containing PIL fiber were at or higher than 0.991 with LODs ranging from 0.5 to 5 mu g L-1. For the PDMS/DVB fiber, R-2 values ranged from 0.992 to 0.999 and LODs were found to be as low as 0.2 mu g L-1 and as high as 5 mu g L-1.
引用
收藏
页码:74 / 82
页数:9
相关论文
共 50 条
  • [21] Insights into the Effect of the PDMS-Layer on the Kinetics and Thermodynamics of Analyte Sorption onto the Matrix-Compatible Solid Phase Microextraction Coating
    Souza-Silva, Erica A.
    Gionfriddo, Emanuela
    Alam, Md. Nazmul
    Pawliszyn, Janusz
    ANALYTICAL CHEMISTRY, 2017, 89 (05) : 2978 - 2985
  • [22] Methylmercury determination in biota by solid-phase microextraction matrix effect evaluation
    Carrasco, Luis
    Diez, Sergi
    Bayona, Josep M.
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1174 (1-2) : 2 - 6
  • [23] Determination of terpenoids in Baijiu using solid-phase extraction combined with headspace solid-phase microextraction
    Feng, Minxue
    Li, Chenyao
    Wang, Chao
    Zhu, Guojun
    Lu, Jun
    Chen, Yefu
    Xiao, Dongguang
    Guo, Xuewu
    INTERNATIONAL JOURNAL OF FOOD PROPERTIES, 2022, 25 (01) : 2445 - 2456
  • [24] Matrix solid-phase dispersion coupled with homogeneous ionic liquid microextraction for the determination of sulfonamides in animal tissues using high-performance liquid chromatography
    Wang, Zhibing
    He, Mengyu
    Jiang, Chunzhu
    Zhang, Fengqing
    Du, Shanshan
    Feng, Wennan
    Zhang, Hanqi
    JOURNAL OF SEPARATION SCIENCE, 2015, 38 (23) : 4127 - 4135
  • [25] Determination of polychlorinated biphenyls in ocean water and bovine milk using crosslinked polymeric ionic liquid sorbent coatings by solid-phase microextraction
    Joshi, Manishkumar D.
    Ho, Tien D.
    Cole, William T. S.
    Anderson, Jared L.
    TALANTA, 2014, 118 : 172 - 179
  • [26] Insight into the extraction mechanism of polymeric ionic liquid sorbent coatings in solid-phase microextraction
    Ho, Tien D.
    Cole, William T. S.
    Augusto, Fabio
    Anderson, Jared L.
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1298 : 146 - 151
  • [28] Matrix solid-phase dispersion microextraction and determination by high-performance liquid chromatography with UV detection of pesticide residues in citrus fruit
    Valenzuela, AI
    Lorenzini, R
    Redondo, MJ
    Font, G
    JOURNAL OF CHROMATOGRAPHY A, 1999, 839 (1-2) : 101 - 107
  • [29] Determination of acetone in seawater using derivatization solid-phase microextraction
    Edward D. Hudson
    Kadek Okuda
    Parisa A. Ariya
    Analytical and Bioanalytical Chemistry, 2007, 388 : 1275 - 1282
  • [30] DETERMINATION OF FATTY-ACIDS USING SOLID-PHASE MICROEXTRACTION
    PAN, L
    ADAMS, M
    PAWLISZYN, J
    ANALYTICAL CHEMISTRY, 1995, 67 (23) : 4396 - 4403