Invasive monitoring of limbic epilepsy using stereotactic depth and subdural strip electrodes: Surgical technique - Commentary

被引:0
|
作者
Wyler, AR
机构
来源
SURGICAL NEUROLOGY | 1997年 / 48卷 / 01期
关键词
D O I
10.1016/S0090-3019(97)90043-4
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
引用
收藏
页码:79 / 79
页数:1
相关论文
共 33 条
  • [11] Variatio delectat: Invasive presurgical evaluation of epilepsy with intracerebral depth electrodes in comparison to subdural electrodes in a case of cryptogenic frontal lobe epilepsy
    Altenmüller D.-M.
    Zeitschrift für Epileptologie, 2016, 29 (3): : 135 - 143
  • [12] Surgical outcomes related to invasive EEG monitoring with subdural grids or depth electrodes in adults: A systematic review and meta-analysis
    Toth, Marton
    Papp, Kata Szilvia
    Gede, Noemi
    Farkas, Kornelia
    Kovacs, Sandor
    Isnard, Jean
    Hagiwara, Koichi
    Gyimesi, Csilla
    Kuperczko, Diana
    Doczi, Tamas
    Janszky, Jozsef
    SEIZURE-EUROPEAN JOURNAL OF EPILEPSY, 2019, 70 : 12 - 19
  • [13] THE MORBIDITY OF LONG-TERM SEIZURE MONITORING USING SUBDURAL STRIP ELECTRODES
    WYLER, AR
    WALKER, G
    SOMES, G
    JOURNAL OF NEUROSURGERY, 1991, 74 (05) : 734 - 737
  • [14] Commentary: Continuous Intraoperative Neurophysiologic Monitoring of the Motor Pathways Using Depth Electrodes During Surgical Resection of an Epileptogenic Lesion: A Novel Technique
    Fountas, Konstantinos
    OPERATIVE NEUROSURGERY, 2021, 20 (05) : E386 - E387
  • [15] Depth versus subdural temporal electrodes revisited: Impact on surgical outcome after resective surgery for epilepsy
    Valentin, A.
    Hernando-Quintana, N.
    Moles-Herbera, J.
    Jimenez-Jimenez, D.
    Mourente, S.
    Malik, I.
    Selway, R. P.
    Alarcon, G.
    CLINICAL NEUROPHYSIOLOGY, 2017, 128 (03) : 418 - 423
  • [16] Frameless Stereotactic Drilling for Placement of Depth Electrodes in Refractory Epilepsy: Operative Technique and Initial Experience
    Dorfer, Christian
    Stefanits, Harald
    Pataraia, Ekaterina
    Wolfsberger, Stefan
    Feucht, Martha
    Baumgartner, Christoph
    Czech, Thomas
    OPERATIVE NEUROSURGERY, 2014, 10 (04) : 582 - 590
  • [17] Complications to invasive epilepsy surgery workup with subdural and depth electrodes: a prospective population-based observational study
    Hedegard, Emelie
    Bjellvi, Johan
    Edelvik, Anna
    Rydenhag, Bertil
    Flink, Roland
    Malmgren, Kristina
    JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 2014, 85 (07): : 716 - 720
  • [19] DETECTION OF HIGH-FREQUENCY OSCILLATIONS IN NEOCORTICAL EPILEPSY PATIENTS USING INVASIVE SUBDURAL ELECTRODES
    Quach, Michael
    Burgess, Richard C.
    Altay, E. E.
    EPILEPSIA, 2008, 49 : 7 - 8
  • [20] Surgical technique for the insertion of grids and strips for invasive monitoring in children with intractable epilepsy
    Bruce, DA
    Bizzi, JWJ
    CHILDS NERVOUS SYSTEM, 2000, 16 (10-11) : 724 - 730