Estimation of the number of people under controlled ventilation using a CO2 concentration sensor

被引:0
|
作者
Ito, Seiya [1 ]
Nishi, Hiroaki [2 ]
机构
[1] Keio Univ, Grad Sch Sci & Technol, Kohoku Ku, 3-14-1 Hiyoshi, Yokohama, Kanagawa 2238522, Japan
[2] Keio Univ, Fac Sci & Technol, Yokohama, Kanagawa 223, Japan
来源
38TH ANNUAL CONFERENCE ON IEEE INDUSTRIAL ELECTRONICS SOCIETY (IECON 2012) | 2012年
关键词
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Recently, many studies dealing with energy saving have been conducted from the viewpoint of mitigating global warming. However, most of them only consider energy saving and ignore the total environmental impact. It is necessary to provide a comfortable work space using efficient and optimized energy control, because excessive demand control can have a negative impact on the environment. It can also have a negative impact on working or learning efficiency. To provide a comfortable indoor environment, it is important to measure environmental indexes, including not only temperature, humidity, illuminance, and wind speed, but also CO2 concentration. Moreover, to forecast air conditioner demand, it is important to know the number of people in the controlled space. In this paper, we propose a new method to estimate the number of people in a ventilation-controlled environment by using a CO2 sensor. The proposed method will provide a demand control system that achieves more intelligent and accurate control of ventilation fans.
引用
收藏
页码:4834 / 4839
页数:6
相关论文
共 50 条
  • [21] Learning-based CO2 concentration prediction: Application to indoor air quality control using demand-controlled ventilation
    Taheri, Saman
    Razban, Ali
    BUILDING AND ENVIRONMENT, 2021, 205
  • [22] Electrochemical conversion of CO2 to formic acid under reduced CO2 concentration
    Yang, Hongzhou
    Kaczur, Jerry
    Masel, Richard
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2019, 257
  • [23] Predictive Modelling of In-vehicle CO2 Concentration using Sensor Data Analytics
    Lohani, Divya
    Barthwal, Anurag
    Acharya, Debopam
    2018 IEEE SENSORS, 2018, : 1472 - 1475
  • [24] Ventilation Rates and Unsatisfied Percentage from Indoor CO2 Concentration
    Costanzo, S.
    Cusumano, A.
    Giaconia, C.
    INDOOR AND BUILT ENVIRONMENT, 2011, 20 (02) : 232 - 245
  • [25] Accurate Prediction of CO2 Concentration using CFD Simulations to Validate Ventilation Strategies to Achieve Healthy CO2 Levels in Indoor Spaces
    Kumar, Praveen R.
    Jadhav, Sandip
    Chavan, Rohit
    ASHRAE TRANSACTIONS 2023, VOL 129, PT 1, 2023, 129 : 598 - 606
  • [26] Rapid Estimation of Column-Averaged CO2 Concentration Using a Correlation Algorithm
    Polonsky, Igor
    O'Brien, D. M.
    JOURNAL OF ATMOSPHERIC AND OCEANIC TECHNOLOGY, 2010, 27 (12) : 2002 - 2016
  • [27] The microprocessor CO2 concentration sensor based on heterostructure optopairs
    Avdonkin, KJ
    Makukha, VK
    EDM 2005: International Workshop and Tutorials on Electron Devices and Materials, Proceedings, 2005, : 153 - 154
  • [28] THE INFLUENCE OF CO2 PRODUCTION AND PHYSIOLOGICAL DEADSPACE ON END-TIDAL CO2 DURING CONTROLLED VENTILATION - A STUDY USING A MECHANICAL MODEL
    STOCKWELL, MA
    BRUCE, W
    SONI, N
    ANAESTHESIA AND INTENSIVE CARE, 1989, 17 (04) : 482 - 486
  • [29] A CO2 sensor operating under high humidity
    Oho, T
    Tonosaki, T
    Isomura, K
    Ogura, K
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2002, 522 (02) : 173 - 178
  • [30] DRY METHOD FOR ESTIMATION OF MIXED VENOUS CO2 CONCENTRATION
    BREY, O
    HOLLOWAY, R
    BMJ-BRITISH MEDICAL JOURNAL, 1971, 4 (5782): : 292 - +