Comparison of Hyperpolarized 3He and 129Xe MRI for the Measurement of Absolute Ventilated Lung Volume in Rats

被引:11
|
作者
Fox, Matthew S. [1 ,2 ]
Ouriadov, Alexei [2 ]
Santyr, Giles E. [2 ,3 ,4 ]
机构
[1] Univ Western Ontario, Dept Phys & Astron, London, ON, Canada
[2] Univ Western Ontario, Robarts Res Inst, Imaging Res Labs, London, ON, Canada
[3] Univ Western Ontario, Dept Med Biophys, London, ON, Canada
[4] Univ Western Ontario, Dept Med Imaging, London, ON, Canada
关键词
apparent diffusion coefficient; helium-3; lung volume; T-2*; xenon-129; REGIONAL VENTILATION; MODEL; EMPHYSEMA; DISEASE; SYSTEM;
D O I
10.1002/mrm.24746
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeMRI using hyperpolarized noble gases, He-3 and Xe-129, provides noninvasive assessments of lung structure and function. Previous work demonstrated that absolute ventilated lung volumes (aVLV) measured in rats using hyperpolarized He-3 agree well with micro-CT. MethodsIn this work, aVLV measurements were performed in rats using hyperpolarized Xe-129 MRI and compared with hyperpolarized He-3 measurements of aVLV under matched ventilation conditions. Whole-lung compliance was also determined. Partial volume, apparent diffusion coefficient, and effective transverse relaxation time corrections were applied during postprocessing to reduce bias between methods. ResultsMean apparent diffusion coefficient of the trachea was 0.830.09 cm(2)/s and 0.067 +/- 0.011 cm(2)/s for He-3 and Xe-129, respectively. Mean apparent diffusion coefficient of parenchyma was 0.21 +/- 0.07 cm(2)/s and 0.027 +/- 0.008 cm(2)/s for He-3 and Xe-129, respectively. Mean transverse relaxation time values were 1.57 +/- 0.25 ms and 2.80 +/- 0.25 ms for He-3 and Xe-129, respectively, in a model trachea and 3.18 +/- 1.00 ms and 4.88 +/- 0.60 ms for He-3 and Xe-129, respectively, for lung parenchyma. Mean aVLV values were 7.07 +/- 0.67 mL and 6.99 +/- 1.00 mL at 14 cmH(2)O and 4.88 +/- 0.71 mL and 5.36 +/- 0.76 mL at 10 cmH(2)O obtained with He-3 and Xe-129, respectively, demonstrating good agreement between Xe-129 and He-3. Conclusions(129)Xe offers an important alternative to He-3 for hyperpolarized gas MRI of aVLV in rats. Magn Reson Med 71:1130-1136, 2014. (c) 2013 Wiley Periodicals, Inc.
引用
收藏
页码:1130 / 1136
页数:7
相关论文
共 50 条
  • [21] In Vivo Lung Morphometry of Lymphangioleiomyomatosis Using Hyperpolarized 129Xe Diffusion MRI
    Bdaiwi, A. S.
    Hossain, M. M.
    Willmering, M. M.
    Wang, H.
    Gupta, N.
    McCormack, F. X.
    Woods, J. C.
    Cleveland, Z., I
    Walkup, L.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2021, 203 (09)
  • [22] Comparison of ventilation defects quantified by Technegas SPECT and hyperpolarized 129Xe MRI
    Radadia, Nisarg
    Friedlander, Yonni
    Priel, Eldar
    Konyer, Norman B.
    Huang, Chynna
    Jamal, Mobin
    Farncombe, Troy
    Marriott, Christopher
    Finley, Christian
    Agzarian, John
    Dolovich, Myrna
    Noseworthy, Michael D.
    Nair, Parameswaran
    Shargall, Yaron
    Svenningsen, Sarah
    FRONTIERS IN PHYSIOLOGY, 2023, 14
  • [23] Hyperpolarized 3He and 129Xe MR Imaging in Healthy Volunteers and Patients with Chronic Obstructive Pulmonary Disease
    Kirby, Miranda
    Svenningsen, Sarah
    Owrangi, Amir
    Wheatley, Andrew
    Farag, Adam
    Ouriadov, Alexei
    Santyr, Giles E.
    Etemad-Rezai, Roya
    Coxson, Harvey O.
    McCormack, David G.
    Parraga, Grace
    RADIOLOGY, 2012, 265 (02) : 600 - 610
  • [24] Ventilation heterogeneity imaged by multibreath wash-ins of hyperpolarized 3He and 129Xe in healthy rabbits
    Hamedani, Hooman
    Kadlecek, Stephen
    Ruppert, Kai
    Xin, Yi
    Duncan, Ian
    Rizi, Rahim R.
    JOURNAL OF PHYSIOLOGY-LONDON, 2021, 599 (17): : 4197 - 4223
  • [25] Hyperpolarized 3He MRI of mouse lung
    Dugas, JP
    Garbow, JR
    Kobayashi, DK
    Conradi, MS
    MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (06) : 1310 - 1317
  • [26] Comparison of 3D UTE free-breathing lung MRI with hyperpolarized 129Xe MRI in pediatric cystic fibrosis
    Munidasa, Samal
    Zanette, Brandon
    Dumas, Marie-Pier
    Wee, Wallace
    Braganza, Sharon
    Li, Daniel
    Ratjen, Felix
    Santyr, Giles
    MAGNETIC RESONANCE IN MEDICINE, 2025, 93 (02) : 775 - 787
  • [27] Comparison of 3D UTE free-breathing lung MRI with hyperpolarized 129Xe MRI in pediatric cystic fibrosis
    Munidasa, Samal
    Zanette, Brandon
    Dumas, Marie-Pier
    Wee, Wallace
    Braganza, Sharon
    Li, Daniel
    Ratjen, Felix
    Santyr, Giles
    MAGNETIC RESONANCE IN MEDICINE, 2024,
  • [28] Hyperpolarized 129Xe MRI for functional assessment of radiation-induced lung injury
    Driehuys, B
    Raidy, T
    Pollaro, J
    Johnson, A
    Dewhirst, M
    Marks, L
    Vujaskovic, Z
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02): : S460 - S461
  • [29] Comparison of inhaled 19F C3F8 and hyperpolarized 129Xe lung ventilation MRI
    Maunder, Adam
    Hughes, Paul J. C.
    Norquay, Graham
    Robb, Fraser
    Rao, Madhwesha
    Wild, Jim
    EUROPEAN RESPIRATORY JOURNAL, 2018, 52
  • [30] Clinical applicability of 3He and 129Xe ventilation MRI in cystic fibrosis: longitudinal follow up
    Smith, Laurie
    Collier, Guilhem
    Marshall, Helen
    Hughes, Paul
    Biancardi, Alberto
    Norquay, Graham
    Bray, Jody
    Rodgers, Oliver
    Wildman, Martin
    West, Noreen
    Horsley, Alex
    Wild, Jim
    EUROPEAN RESPIRATORY JOURNAL, 2019, 54