A Novel Type of Dental Tube Implant for Areas with Limited Bone Height. Clinical and Radiographic Data from Three Patients with 5-Year Follow-Up

被引:3
|
作者
Lundgren, Dan [1 ]
Slotte, Christer [1 ,2 ]
Grondahl, Kerstin [2 ]
机构
[1] Univ Gothenburg, Inst Clin Sci, Dept Biomat, Sahlgrenska Acad, Gothenburg, Sweden
[2] Inst Postgrad Dent Educ, SE-55111 Jonkoping, Sweden
关键词
case report; follow-up; implant; limited bone height; GUIDED BONE; HOLLOW IMPLANTS; RABBIT SKULL; AUGMENTATION; MODEL;
D O I
10.1111/j.1708-8208.2011.00414.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background: Alternative implant designs may reduce the need for complicated and costly bone augmentation procedures in situations with limited bone height. Purpose: Wide dental tube implants have been manufactured and tested in three patients and followed for 5 years to evaluate if such implants are capable to support fixed prosthetic constructions with good prognosis in areas with limited bone height. Materials and Methods: Four machined-tube implants with a height of 6 mm, an outer diameter of 7.4 mm, and an inner diameter of 6.0 mm were placed in three patients. After a healing period of 3 months, ceramometal suprastructures were constructed to supply the implants. Annual clinical and radiographical follow-ups were done up to 5 years. At the 5-year follow-up, all three patients were examined with a cone beam computed tomography technique. Results: All implants and the suprastructures were clinically stable after 5 years. In one patient, vertical bone loss and a 6-mm deep pocket appeared after 1 year. The pocket has remained throughout the observation period and has been regularly debrided and kept it free from clinical signs of inflammation. In the other two patients, the soft tissue surrounding the implants was in good health with no or only slight inflammation throughout all observations. Pocket probing revealed no or slight bleeding and pocket depths amounting to less than 3 mm. Conclusion: It was shown that this new type of implant will function excellent during follow-up times of several years. Further studies should be done to explore in more detail indications for such implants.
引用
收藏
页码:509 / 516
页数:8
相关论文
共 50 条
  • [41] Musculoskeletal disorders among female dental personnel – clinical examination and a 5-year follow-up study of symptoms
    I. Åkesson
    B. Johnsson
    L. Rylander
    U. Moritz
    S. Skerfving
    International Archives of Occupational and Environmental Health, 1999, 72 : 395 - 403
  • [42] Clinical and radiographic evaluation of implants placed by means of inferior alveolar nerve lateralization: a 5-year follow-up study
    Martinez-Rodriguez, Natalia
    Barona-Dorado, Cristina
    Cortes-Breton Brinkmann, Jorge
    Martin Ares, Maria
    Luis Calvo-Guirado, Jose
    Maria Martinez-Gonzalez, Jose
    CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 (07) : 779 - 784
  • [43] Clinical, Radiographic, and Patient-Perceived Outcome After Radial Hemi-Wrist Arthroplasty With a New Implant: 20 Cases With 5-Year Follow-up
    Reiser, Daniel
    Sagerfors, Marcus
    Wretenberg, Per
    Pettersson, Kurt
    Fischer, Per
    HAND-AMERICAN ASSOCIATION FOR HAND SURGERY, 2024, 19 (05): : 742 - 750
  • [44] Chronic hand eczema in Germany: 5-year follow-up data from the CARPE registry
    Apfelbacher, Christian J.
    Ofenloch, Robert F.
    Weisshaar, Elke
    Molin, Sonja
    Bauer, Andrea
    Mahler, Vera
    Heinrich, Andreas
    von Kiedrowski, Ralph
    Schmitt, Jochen
    Elsner, Peter
    Diepgen, Thomas L.
    CONTACT DERMATITIS, 2019, 80 (01) : 45 - 53
  • [45] The changes of the height, weight, and body mass index of elderly - Findings from a 5-year follow-up study
    Chiu, H
    Chen, Y
    GERONTOLOGIST, 2003, 43 : 12 - 12
  • [46] Construction of a prognostic prediction model for colorectal cancer based on 5-year clinical follow-up data
    Xiao, Boao
    Yang, Min
    Meng, Yao
    Wang, Weimin
    Chen, Yuan
    Yu, Chenglong
    Bai, Longlong
    Xiao, Lishun
    Chen, Yansu
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [47] Comparison of peri-implant marginal bone level changes between tapered and straight implant designs: 5-year follow-up results
    Park, Han
    Moon, Ik-Sang
    Chung, Chooryung
    Shin, Su-Jung
    Huh, Jong-Ki
    Yun, Jeong-Ho
    Lee, Dong-Won
    JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, 2021, 51 (06): : 422 - 432
  • [48] Flapless Extraction and Immediate Implant Placed Into a Mandibular Molar Site: A Clinical Case Report and 5-Year Follow-Up
    Natto, Zuhair S.
    JOURNAL OF ORAL IMPLANTOLOGY, 2019, 45 (02) : 159 - 164
  • [49] Clinical and radiographic evaluation of early loaded narrow-diameter implants: 5-year follow-up of a multicenter prospective clinical study
    Galindo-Moreno, Pablo
    Nilsson, Peter
    King, Paul
    Worsaae, Nils
    Schramm, Alexander
    Padial-Molina, Miguel
    Maiorana, Carlo
    CLINICAL ORAL IMPLANTS RESEARCH, 2017, 28 (12) : 1584 - 1591
  • [50] EVALUATION OF OSTEOPOROSIS AND FRACTURES IN PATIENTS WITH DIABETES MELLITUS TYPE 2: RESULTS OF A 5-YEAR FOLLOW-UP
    Masenko, V. L.
    Kokov, A. N.
    Semenov, S. E.
    Raskina, T. A.
    Barbarash, O. L.
    ANNALS OF THE RHEUMATIC DISEASES, 2017, 76 : 1346 - 1346