Hydrophilic interaction liquid chromatography columns classification by effect of solvation and chemometric methods

被引:60
|
作者
Noga, Sylwia [1 ]
Bocian, Szymon [1 ]
Buszewski, Boguslaw [1 ]
机构
[1] Nicholas Copernicus Univ, Fac Chem, Chair Environm Chem & Bioanalyt, PL-87100 Torun, Poland
关键词
Excess adsorption; HILIC; Solvation; Stationary bonded phase; Water adsorption; CHEMICALLY BONDED PHASES; SILICA STATIONARY-PHASE; REVERSED-PHASE; EXCESS ADSORPTION; SURFACE HETEROGENEITY; RETENTION MECHANISMS; SOLVENT ADSORPTION; ELUENT COMPONENTS; PACKING MATERIALS; POLAR COMPOUNDS;
D O I
10.1016/j.chroma.2012.12.077
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In the current work, a 14 different types of stationary phases with specific structural properties (eight commercially available stationary phases and six home-made) have been studied. We used the minor disturbance method to measure the excess adsorption isotherms of water onto surface of chemically bonded stationary phases from water-acetonitrile mixtures. The presence of polar and hydrophobic groups in the structures of adsorbents as well as changes in the mobile phase composition causes the excess adsorption of given solvent when its concentration in the mobile phase is low. The excess adsorption of water is observed in acetonitrile-rich mobile phase and the excess adsorption of acetonitrile is observed in water-rich mobile phase. The maximum excess of adsorbed water is connected with a negative excess of adsorbed acetonitrile. However, the scale of these excess adsorption depend on the type of the stationary bonded phases. The retention factors of three test solutes (tryptophan, glycine and proline) are correlated with the maximum amount of excessively adsorbed water on the stationary bonded phase surface. Linear dependence of retention factor with excess amount of water suggest, that the amount of adsorbed water ("hydrophilic pillow") play an important role in the retention mechanism in HILIC. All tested stationary phases were divided into several groups according to the retention factors of 16 different biologically active compounds (selected amino acids, pesticides, vitamin B6). Principal component analysis (PCA) and cluster analysis (CA) analysis were used in column comparison and grouping. CA results indicated that all stationary phases may be generally grouped into several clusters, due to structure and properties of stationary phases. Interesting results were obtained also with the use of PCA. Presented methodologycan provide useful information on the hydrophilic properties of various polar columns and their suitability for HILIC applications. (c) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:89 / 97
页数:9
相关论文
共 50 条
  • [21] Effect of nature of electrolytes on retention and selectivity in hydrophilic interaction liquid chromatography
    Craven, Caley B.
    Joyce, Cole W.
    Lucy, Charles A.
    JOURNAL OF CHROMATOGRAPHY A, 2019, 1584 : 80 - 86
  • [22] Hydrophilic interaction liquid chromatography in food analysis
    Bernal, Jose
    Ares, Ana M.
    Pol, Jaroslav
    Wiedmer, Susanne K.
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (42) : 7438 - 7452
  • [23] Investigation of Reequilibration in Hydrophilic Interaction Liquid Chromatography
    Shollenberger, Daniel L.
    Bell, David S.
    LC GC EUROPE, 2016, 29 (12) : 687 - 692
  • [24] New developments in hydrophilic interaction liquid chromatography
    Janson, Jan-Christer
    JOURNAL OF BIOSCIENCE AND BIOENGINEERING, 2009, 108 : S59 - S59
  • [25] Investigation of Reequilibration in Hydrophilic Interaction Liquid Chromatography
    Shollenberger, Daniel L.
    Bell, David S.
    LC GC NORTH AMERICA, 2016, 34 (12) : 894 - 899
  • [26] Hydrophilic interaction liquid chromatography (HILIC) in proteomics
    Boersema, Paul J.
    Mohammed, Shabaz
    Heck, Albert J. R.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 391 (01) : 151 - 159
  • [27] Is hydrophilic interaction chromatography with silica columns a viable alternative to reversed-phase liquid chromatography for the analysis of ionisable compounds?
    McCalley, David V.
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1171 (1-2) : 46 - 55
  • [28] Hydrophilic interaction liquid chromatography (HILIC) in proteomics
    Paul J. Boersema
    Shabaz Mohammed
    Albert J. R. Heck
    Analytical and Bioanalytical Chemistry, 2008, 391 : 151 - 159
  • [29] HYDROPHILIC-INTERACTION CHROMATOGRAPHY OF PEPTIDES ON HYDROPHILIC AND STRONG CATION-EXCHANGE COLUMNS
    ZHU, BY
    MANT, CT
    HODGES, RS
    JOURNAL OF CHROMATOGRAPHY, 1991, 548 (1-2): : 13 - 24
  • [30] Zwitterionic silica-based monolithic capillary columns for isocratic and gradient hydrophilic interaction liquid chromatography
    Moravcova, Dana
    Planeta, Josef
    Kahle, Vladislav
    Roth, Michal
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1270 : 178 - 185