Preliminary performance test of tubular neutron detector based on SiPM signal readout

被引:0
|
作者
Liu Yun [1 ,4 ]
Tang Bin [2 ,3 ,4 ]
Wu Chong [1 ,6 ]
Huang Chang [4 ,7 ]
Sun Zhi-Jia [2 ,3 ,4 ,5 ]
Zhang Yan-chao [1 ]
Lin Chun-Dan [1 ]
机构
[1] China Univ Petr, Beijing 102249, Peoples R China
[2] Chinese Acad Sci, Inst High Energy Phys, State Key Lab Particle Detect & Elect, Beijing 100049, Peoples R China
[3] Chinese Acad Sci, Inst High Energy Phys, China Spallat Neutron Source, Dongguan 523803, Peoples R China
[4] Dongguan Inst Neutron Sci, Dongguan 523808, Peoples R China
[5] Sun Yat Sen Univ, Sino French Inst Nucl Engn & Technol, Zhuhai 519082, Peoples R China
[6] China Univ Petr Beijing Karamay, Karamay 834000, Peoples R China
[7] Lanzhou Univ, Coll Sci & Technol, Lanzhou 730000, Peoples R China
关键词
scintillator neutron detector; 6 LiF/ZnS(Ag) scintillator; Wavelength shifting fiber; detection efficiency; SiPM; MC simulation;
D O I
10.1117/12.2524696
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Due to the shortage and the rapidly increasing price of the 3 He gas, seeking new types of position-sensitive neutron detectors is urgent. In order to fulfill the requirements of Chinese neutron spectrometers for neutron detectors, the research on neutron detector based on (LiF)-Li-6 / ZnS (Ag) scintillator and wavelength-shifting fiber (WLSF) structure neutron detectors was developed. It has the advantages of high neutron detection efficiency, good position resolution and the ability to splicing large areas. This paper proposed a tubular neutron detector structure. It consists of two layers of rolled (LiF)-Li-6/ZnS(Ag) scintillators sandwich with two wavelength-shifting fibers, and two SiPMs (Silicon photomultipliers) for the photons readout. By MC simulation, we obtained the thermal neutron conversion efficiency of (LiF)-Li-6/ZnS(Ag) scintillation screens with different thicknesses and rolled diameters, and optimized the detector structure. The characteristics of the key components are studied. A small detector prototype has been constructed. and been tested by the neutron beam. The preliminary test results showed that the detector can work well.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Digitized signal acquisition of gas-filled, multiwire, neutron detector with delay-line readout
    Orban, J.
    Rosta, L.
    Nagy, A.
    INTERNATIONAL WORKSHOP ON NEUTRON OPTICS AND DETECTORS (NOP&D 2013), 2014, 528
  • [42] The Anticoincidence System of Space-Based Gamma-Ray Telescope GAMMA-400, Test Beam Studies of Anticoincidence Detector Prototype with SiPM Readout
    Arkhangelskiy, A. I.
    Galper, A. M.
    Arkhangelskaja, I. V.
    Bakaldin, A. V.
    Chernysheva, I. V.
    Dalkarov, O. D.
    Egorov, A. E.
    Gusakov, Yu. V.
    Kheymits, M. D.
    Leonov, A. A.
    Pappe, N. Yu.
    Runtso, M. F.
    Stozhkov, Yu. I.
    Suchkov, S. I.
    Topchiev, N. P.
    Yurkin, Yu. T.
    PHYSICS OF ATOMIC NUCLEI, 2020, 83 (02) : 252 - 257
  • [43] SiPM-based detector for high resolution measurements in pulsed radiation fields: preliminary findings
    Pavelic, L.
    Lackovic, I.
    Mihic, M. Suric
    Prlic, I.
    2019 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2019,
  • [44] Preliminary timing measurements on a data acquisition chain for a SiPM-based detector for prostate imaging
    Gabrielli, A.
    Antonioli, P.
    D'Antone, I.
    Giorgi, F. M.
    Lax, I.
    Lolli, M.
    De Leo, R.
    De Robertis, G.
    Foresta, M.
    Loddo, F.
    Ranieri, A.
    Cosentino, G.
    Finocchiaro, P.
    Pappalardo, A. D.
    Fonte, R.
    Calvini, C.
    Musico, P.
    Ottonello, P.
    Cusanno, F.
    Garibaldi, F.
    Gigli, T.
    Giove, F.
    Maraviglia, B.
    Meddi, F.
    Rivetti, A.
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2011, 215 : 165 - 167
  • [45] Research on Nuclear Signal Generator Based on Signal Characteristics of Pulsed Neutron Detector
    Luo, Tingfang
    Bao, Chao
    Gao, Zhiyu
    Wang, Li
    Sun, Qi
    Hedongli Gongcheng/Nuclear Power Engineering, 2024, 45 (06): : 159 - 165
  • [46] DESIGN AND PRELIMINARY TEST OF A LARGE AREA POSITION-SENSITIVE NEUTRON DETECTOR
    BERLINER, R
    MILDNER, DFR
    BRUGGER, RM
    KING, JS
    WERNER, SA
    YELON, WB
    PRINGLE, A
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1978, 23 (03): : 391 - 392
  • [47] Prototype of Position-Sensitive Scintillation Neutron Detector Based on SiPM and ZnS:Li6
    Glushkova, T. I.
    Trunov, D. N.
    Marin, V. N.
    Sadykov, R. A.
    Aksenov, S. N.
    JOURNAL OF SURFACE INVESTIGATION, 2023, 17 (01): : 130 - 134
  • [48] Prototype of Position-Sensitive Scintillation Neutron Detector Based on SiPM and ZnS:Li6
    T. I. Glushkova
    D. N. Trunov
    V. N. Marin
    R. A. Sadykov
    S. N. Aksenov
    Journal of Surface Investigation: X-ray, Synchrotron and Neutron Techniques, 2023, 17 : 130 - 134
  • [49] The beam test of anticoincidence scintillation detector prototype with SiPM readout and perspectives of GRBs studies for space-based gamma-ray telescope GAMMA-400
    Arkhangelskiy, A. I.
    Galper, A. M.
    Arkhangelskaja, I. V.
    Bakaldin, A. V.
    Chasovikov, E. N.
    Chernysheva, I. V.
    Dalkarov, O. D.
    Egorov, A. E.
    Gusakov, Yu V.
    Kheymits, M. D.
    Leonov, A. A.
    Pappe, N. Yu
    Runtso, M. F.
    Stozhkov, Yu I.
    Suchkov, S. I.
    Topchiev, N. P.
    Yurkin, Y. T.
    4TH INTERNATIONAL CONFERENCE ON PARTICLE PHYSICS AND ASTROPHYSICS (ICPPA-2018), 2019, 1390
  • [50] Performance Comparison of SiPM and PMT Based Preclinical PET Systems with Same Detector Geometries
    Krizsan, A. K.
    Lajtos, I.
    Emri, M.
    Kis, S. A.
    Opposits, G.
    Hegyesi, G.
    Kalinka, G.
    Gal, J.
    Kiraly, B.
    Imrek, J.
    Valastyan, I.
    Molnar, J.
    Sanfilippo, D.
    Dahlbom, M.
    Balkay, L.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 : S360 - S360