Electret based wireless micro ionizing radiation dosimeter

被引:0
|
作者
Son, C [1 ]
Ziaie, B [1 ]
机构
[1] Purdue Univ, Sch Elect & Comp Engn, W Lafayette, IN 47907 USA
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Wireless ionizing radiation sensors have a wide range of applications in areas Such as radiation therapy, environmental monitoring, and homeland security. It is preferable to manufacture such sensors using passive elements since ionizing radiation can damage active electronic components. This paper reports the development of a first micromachined totally passive electret based wireless ionizing radiation dosimeter for high dose radiation therapy applications. Wireless Ionizing radiation measurement is performed by monitoring the resonance frequency change with a phase-dip technique. Device test results show that 60,000R gamma-ray ionizing radiation exposure produces a 687kHz resonance frequency shift resulting in a sensitivity of 11.45kHz/kR.
引用
收藏
页码:610 / 613
页数:4
相关论文
共 50 条
  • [31] EFFECT OF THE IONIZING-RADIATION ON THE PYROELECTRICAL PROPERTIES OF ELECTRET POLYMER-FILMS
    VANNIKOV, AV
    LIKHOVIDOV, VS
    SITSHKAR, VP
    VYSOKOMOLEKULYARNYE SOEDINENIYA SERIYA B, 1979, 21 (10): : 742 - 746
  • [32] DESIGN AND PERFORMANCE OF A TEFLON ELECTRET DOSIMETER CHARGER
    KOTRAPPA, P
    GUPTA, PC
    DUA, SK
    HEALTH PHYSICS, 1980, 39 (03): : 566 - 568
  • [33] PERFORMANCE OF A PASSIVE ELECTRET DOSIMETER FOR RN PROGENY
    KHAN, A
    PHILLIPS, CR
    HEALTH PHYSICS, 1985, 49 (05): : 986 - 991
  • [34] ELECTRET DOSIMETER FOR NEUTRONS AND GAMMA-RAYS
    IKEYA, M
    JAPANESE JOURNAL OF APPLIED PHYSICS, 1981, 20 (08) : 1615 - 1616
  • [35] CHEMICAL DOSIMETER FOR IONIZING RADIATIONS
    KANWISHER, JW
    NUCLEONICS, 1952, 10 (05): : 62 - &
  • [36] A FILM-DOSIMETER-SYSTEM FOR HIGHDOSE-DOSIMETRY OF IONIZING-RADIATION
    IHME, B
    DORSCHNER, H
    HEGER, A
    RADIATION PHYSICS AND CHEMISTRY, 1986, 28 (5-6) : 621 - 623
  • [37] Sucrose as double-signal high-dose dosimeter for ionizing radiation
    Peimel-Stuglik, Zofia
    Fabisiak, Slawomir
    RADIATION PHYSICS AND CHEMISTRY, 2009, 78 (7-8) : 449 - 452
  • [38] Charge density measurement of electret filters using alpha-ray ionizing radiation
    Romay, Francisco J.
    Liu, Benjamin Y. H.
    Chae, Soo-Jae
    Filtration and Separation, 1999, 36 (04): : 51 - 56
  • [39] Charge density measurement of electret filters using alpha-ray ionizing radiation
    Romay, FJ
    Liu, BYH
    Chae, SJ
    FILTRATION + SEPARATION, 1999, 36 (04) : 51 - 56
  • [40] The effect of humidity on the accuracy of measurement of an electret radon dosimeter
    Mahat, RH
    Bradley, DA
    Amin, YM
    Wong, CY
    Su, LD
    RADIATION PHYSICS AND CHEMISTRY, 2001, 61 (3-6) : 489 - 490