Objective Evaluation of Cervical Dystonia Using an Inertial Sensor-Based System

被引:2
|
作者
Park, Jonghyun [1 ]
Yang, Kyung Yong [3 ]
Lee, Joonnyong [1 ]
Youn, Kibum [3 ]
Lee, Jehee [3 ]
Chung, Sun Gun [2 ]
Kim, Hee Chan [4 ]
Kim, Keewon [2 ,4 ]
机构
[1] Seoul Natl Univ, Interdisciplinary Program Bioengn, Grad Sch, Seoul, South Korea
[2] Seoul Natl Univ, Dept Rehabil Med, Coll Med, Seoul, South Korea
[3] Seoul Natl Univ, Sch Comp Sci & Engn, Seoul, South Korea
[4] Seoul Natl Univ, Dept Biomed Engn, Coll Med, Seoul, South Korea
基金
新加坡国家研究基金会;
关键词
Cervical dystonia; Inertial sensor; Objective evaluation; Euler angle; Axis-angle; Kinematics; RATING-SCALES; MOVEMENTS; RANGE;
D O I
10.1007/s40846-018-0400-3
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Cervical dystonia (CD) is a chronic neurological movement disorder that causes involuntary neck muscle contractions, leading to abnormal movements or posture of the head. However, objective evaluation of severity of CD is lacking in the clinical practice. This study aimed to provide an objective evaluation of the severity of CD based on three-dimensional (3D) kinematics of the neck using wearable inertial sensors. Each inertial sensor was attached to the anterior chest and head of eight patients with idiopathic CD. The involuntary movements of neck were quantified by the rotation angle (RA) and magnitude of angular velocity (MAV) through axis-angle representation expressing 3D rotation. The characteristic posture of each patient was visualized. Four kinematic parameters, the mean and peak values of RA and MAV (Mean(angle), Peak(angle), Mean(vel), and Peak(vel)) were calculated and correlation between each parameter values and the Toronto Western Spasmodic Torticollis Rating Scale (TWSTRS) scores from all patients was analyzed to assess clinical validity. The test-retest reliability of the parameters was examined as well. Correlation coefficients of the Mean(angle) and Peak(angle) with TWSTRS were 0.28 and 0.69, respectively, whereas those of the Mean(vel) and Peak(vel) were 0.84 and 0.84, respectively. The MAV parameters showed a higher correlation with clinical severity than RA parameters. The intraclass correlation coefficients of the four parameters between the test-retest were more than 0.9. We conclude that objective evaluation of severity of CD based on kinematic parameters is clinically valid and has test-retest reliability.
引用
收藏
页码:305 / 314
页数:10
相关论文
共 50 条
  • [31] Survey on inertial sensor-based ILS for smartphone users
    Panja, Ayan Kumar
    Chowdhury, Chandreyee
    Neogy, Sarmistha
    CCF TRANSACTIONS ON PERVASIVE COMPUTING AND INTERACTION, 2022, 4 (03) : 319 - 337
  • [32] Survey on inertial sensor-based ILS for smartphone users
    Ayan Kumar Panja
    Chandreyee Chowdhury
    Sarmistha Neogy
    CCF Transactions on Pervasive Computing and Interaction, 2022, 4 : 319 - 337
  • [33] Inertial Sensor-Based Slip Detection in Human Walking
    Trkov, Mitja
    Chen, Kuo
    Yi, Jingang
    Liu, Tao
    IEEE TRANSACTIONS ON AUTOMATION SCIENCE AND ENGINEERING, 2019, 16 (03) : 1399 - 1411
  • [34] Objective Detection and Quantification of Irregular Gait With a Portable Inertial Sensor-Based System in Horses During an Endurance Race-a Preliminary Assessment
    Lopes, Marco A. F.
    Eleuterio, Angela
    Mira, Monica C.
    JOURNAL OF EQUINE VETERINARY SCIENCE, 2018, 70 : 123 - 129
  • [35] Use of a wireless, inertial sensor-based system to objectively evaluate flexion tests in the horse
    Marshall, J. F.
    Lund, D. G.
    Voute, L. C.
    EQUINE VETERINARY JOURNAL, 2012, 44 : 8 - 11
  • [36] Evaluation of swallowing function using an optical sensor-based system for in-home nursing
    Kurihara, Yousuke
    Omura, Rintaro
    Watanabe, Kajiro
    2006 SICE-ICASE INTERNATIONAL JOINT CONFERENCE, VOLS 1-13, 2006, : 5847 - +
  • [37] An inertial sensor-based system can objectively assess diagnostic anaesthesia of the equine foot
    Maliye, S.
    Voute, L.
    Lund, D.
    Marshall, J. F.
    EQUINE VETERINARY JOURNAL, 2013, 45 : 26 - 30
  • [38] EDA Sensor-based Evaluation of a Vegetation Succession Learning System
    Kawaguchi, Shuya
    Mizoguchi, Hiroshi
    Egusa, Ryohei
    Takeda, Yoshiaki
    Yamaguchi, Etsuji
    Inagaki, Shigenori
    Kusunoki, Fusako
    Funaoi, Hideo
    Sugimoto, Masanori
    2018 12TH INTERNATIONAL CONFERENCE ON SENSING TECHNOLOGY (ICST), 2018, : 353 - 357
  • [39] The largest inertial sensor-based gait database and performance evaluation of gait-based personal authentication
    Thanh Trung Ngo
    Makihara, Yasushi
    Nagahara, Hajime
    Mukaigawa, Yasuhiro
    Yagi, Yasushi
    PATTERN RECOGNITION, 2014, 47 (01) : 228 - 237
  • [40] Height Compensation Using Ground Inclination Estimation in Inertial Sensor-Based Pedestrian Navigation
    Park, Sang Kyeong
    Suh, Young Soo
    SENSORS, 2011, 11 (08) : 8045 - 8059