Objective Evaluation of Cervical Dystonia Using an Inertial Sensor-Based System

被引:2
|
作者
Park, Jonghyun [1 ]
Yang, Kyung Yong [3 ]
Lee, Joonnyong [1 ]
Youn, Kibum [3 ]
Lee, Jehee [3 ]
Chung, Sun Gun [2 ]
Kim, Hee Chan [4 ]
Kim, Keewon [2 ,4 ]
机构
[1] Seoul Natl Univ, Interdisciplinary Program Bioengn, Grad Sch, Seoul, South Korea
[2] Seoul Natl Univ, Dept Rehabil Med, Coll Med, Seoul, South Korea
[3] Seoul Natl Univ, Sch Comp Sci & Engn, Seoul, South Korea
[4] Seoul Natl Univ, Dept Biomed Engn, Coll Med, Seoul, South Korea
基金
新加坡国家研究基金会;
关键词
Cervical dystonia; Inertial sensor; Objective evaluation; Euler angle; Axis-angle; Kinematics; RATING-SCALES; MOVEMENTS; RANGE;
D O I
10.1007/s40846-018-0400-3
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Cervical dystonia (CD) is a chronic neurological movement disorder that causes involuntary neck muscle contractions, leading to abnormal movements or posture of the head. However, objective evaluation of severity of CD is lacking in the clinical practice. This study aimed to provide an objective evaluation of the severity of CD based on three-dimensional (3D) kinematics of the neck using wearable inertial sensors. Each inertial sensor was attached to the anterior chest and head of eight patients with idiopathic CD. The involuntary movements of neck were quantified by the rotation angle (RA) and magnitude of angular velocity (MAV) through axis-angle representation expressing 3D rotation. The characteristic posture of each patient was visualized. Four kinematic parameters, the mean and peak values of RA and MAV (Mean(angle), Peak(angle), Mean(vel), and Peak(vel)) were calculated and correlation between each parameter values and the Toronto Western Spasmodic Torticollis Rating Scale (TWSTRS) scores from all patients was analyzed to assess clinical validity. The test-retest reliability of the parameters was examined as well. Correlation coefficients of the Mean(angle) and Peak(angle) with TWSTRS were 0.28 and 0.69, respectively, whereas those of the Mean(vel) and Peak(vel) were 0.84 and 0.84, respectively. The MAV parameters showed a higher correlation with clinical severity than RA parameters. The intraclass correlation coefficients of the four parameters between the test-retest were more than 0.9. We conclude that objective evaluation of severity of CD based on kinematic parameters is clinically valid and has test-retest reliability.
引用
收藏
页码:305 / 314
页数:10
相关论文
共 50 条
  • [1] Objective Evaluation of Cervical Dystonia Using an Inertial Sensor-Based System
    Jonghyun Park
    Kyung Yong Yang
    Joonnyong Lee
    Kibum Youn
    Jehee Lee
    Sun Gun Chung
    Hee Chan Kim
    Keewon Kim
    Journal of Medical and Biological Engineering, 2019, 39 : 305 - 314
  • [2] Mastication Evaluation With Unsupervised Learning: Using an Inertial Sensor-Based System
    Lucena, Caroline Vieira
    Lacerda, Marcelo
    Caldas, Rafael
    De Lima Neto, Fernando Buarque
    Rativa, Diego
    IEEE JOURNAL OF TRANSLATIONAL ENGINEERING IN HEALTH AND MEDICINE, 2018, 6
  • [3] Assessment of repeatability of a wireless, inertial sensor-based lameness evaluation system for horses
    Keegan, Kevin G.
    Kramer, Joanne
    Yonezawa, Yoshiharu
    Maki, Hiromitchi
    Pai, P. Frank
    Dent, Eric V.
    Kellerman, Thomas E.
    Wilson, David A.
    Reed, Shannon K.
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2011, 72 (09) : 1156 - 1163
  • [4] Novel, sensor-based quantitative cervical elastography: objective quantification of cervical softness
    Stout, Molly
    Zhao, Peinan
    Hu, Peng
    Qu, Yuan
    Chubiz, Jessica
    Maslov, Konstantin
    Garcia, Julio Isla
    Wang, Lihong
    Macones, George A.
    Tuuli, Methodius G.
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2019, 220 (01) : S13 - S13
  • [5] Measurement of the dynamics in ski jumping using a wearable inertial sensor-based system
    Chardonnens, Julien
    Favre, Julien
    Cuendet, Florian
    Gremion, Gerald
    Aminian, Kamiar
    JOURNAL OF SPORTS SCIENCES, 2014, 32 (06) : 591 - 600
  • [6] Sprint mechanics evaluation using inertial sensor-based technology: A laboratory validation study
    Setuain, I.
    Lecumberri, P.
    Ahtiainen, J. P.
    Mero, A. A.
    Hakkinen, K.
    Izquierdo, M.
    SCANDINAVIAN JOURNAL OF MEDICINE & SCIENCE IN SPORTS, 2018, 28 (02) : 463 - 472
  • [7] Examination of the reliability of an inertial sensor-based gait analysis system
    Orlowski, Katja (katja.orlowski@th-brandenburg.de), 2017, Walter de Gruyter GmbH (62):
  • [8] Examination of the reliability of an inertial sensor-based gait analysis system
    Orlowski, Katja
    Eckardt, Falko
    Herold, Fabian
    Aye, Norman
    Edelmann-Nusser, Juergen
    Witte, Kerstin
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2017, 62 (06): : 615 - 622
  • [9] Inertial Sensor-Based Sport Activity Advisory System Using Machine Learning Algorithms
    Patalas-Maliszewska, Justyna
    Pajak, Iwona
    Krutz, Pascal
    Pajak, Grzegorz
    Rehm, Matthias
    Schlegel, Holger
    Dix, Martin
    SENSORS, 2023, 23 (03)
  • [10] On Single Sensor-Based Inertial Navigation
    Strozzi, Nicolo
    Parisi, Federico
    Ferrari, Gianluigi
    2016 IEEE 13TH INTERNATIONAL CONFERENCE ON WEARABLE AND IMPLANTABLE BODY SENSOR NETWORKS (BSN), 2016, : 300 - 305