Intra-aneurysmal pressure after incomplete endovascular exclusion

被引:66
|
作者
Parodi, JC
Berguer, R
Ferreira, LM
La Mura, R
Schermerhorn, ML
机构
[1] Inst Cardiovasc Buenos Aires, Serv Vasc Surg, RA-1428 Buenos Aires, DF, Argentina
[2] Wayne State Univ, Harper Univ Hosp, Serv Vasc Surg, Detroit, MI 48202 USA
关键词
D O I
10.1067/mva.2001.119038
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: An endoleak results from the incomplete endovascular exclusion of an aneurysm. We developed an experimental model to analyze hemodynamic changes within the aneurysm sac in the presence of an endoleak, with and without a simulated open collateral branch. Methods. With a latex aneurysm model connected to a pulsatile pump, pressures were measured simultaneously within the system (systemic pressure) and the aneurysm sac (intrasac pressure). The experiments were performed without endoleak (control group) and after creating a 3.5-mm. (group 1), 4.5-mm (group 2), and 6-mm (group 3) diameter orifice in the endograft, simulating an endoleak. Pressures were also registered with and without a patent aneurysm side branch. Results. In each endoleak group, the intrasac diastolic pressure (DP) and mean pressure (MP) were significantly higher than the systemic DP and MP (P = .01, P = .006, and P = .001, respectively), although the pressure curve was damped. The presence of an open side branch significantly reduced the intrasac DP and MP. Conclusion: In this model, intrasac pressures were significantly higher than systemic pressures in the presence of all endoleaks, even the smallest ones. Intrasac pressures higher than systemic pressure may pose a high risk for aneurysm rupture. Although patent side branches significantly reduce these pressures, the aggressive management of an endoleak should be pursued.
引用
收藏
页码:909 / 914
页数:6
相关论文
共 50 条
  • [31] Interplay between coagulation and inflammation in open and endovascular abdominal aortic aneurysm repair -: Impact of intra-aneurysmal thrombus
    Aho, P.-S.
    Niemi, T.
    Piilonen, A.
    Lassila, R.
    Renkonen, R.
    Lepantalo, M.
    SCANDINAVIAN JOURNAL OF SURGERY, 2007, 96 (03) : 229 - 235
  • [32] Intra-Aneurysmal Pressure and Flow Changes Induced by Flow Diverters: Relation to Aneurysm Size and Shape
    Larrabide, I.
    Aguilar, M. L.
    Morales, H. G.
    Geers, A. J.
    Kulcsar, Z.
    Ruefenacht, D.
    Frangi, A. F.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2013, 34 (04) : 816 - 822
  • [33] INTRA-ANEURYSMAL FLOW COMPLEXITY QUANTIFICATION USING FLOWLINES GEOMETRY
    Hodis, Simona
    Kallmes, David F.
    Dragomir-Daescu, Dan
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2013, PT A, 2014,
  • [34] Simulation of Intra-Aneurysmal Blood Flow by Different Numerical Methods
    Weichert, Frank
    Walczak, Lars
    Fisseler, Denis
    Opfermann, Tobias
    Razzaq, Mudassar
    Muenster, Raphael
    Turek, Stefan
    Grunwald, Iris
    Roth, Christian
    Veith, Christian
    Wagner, Mathias
    COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2013, 2013
  • [35] Unraveling the relationship between arterial flow and intra-aneurysmal hemodynamics
    Morales, Hernan G.
    Bonnefous, Odile
    JOURNAL OF BIOMECHANICS, 2015, 48 (04) : 585 - 591
  • [36] Intra-aneurysmal Onyx embolization for distal aneurysms of the cerebellar arteries
    Gao, Xu
    Liang, Guobiao
    Li, Zhiqing
    Wang, Xiaogang
    Wei, Xuezhong
    Zhang, Haifeng
    Feng, Sizhe
    Lin, Jun
    NEUROLOGICAL RESEARCH, 2012, 34 (02) : 211 - 216
  • [37] Analysis of Intra-Aneurysmal Flow for Cerebral Aneurysms with Cerebral Angiography
    Jou, L. -D.
    Mawad, M. E.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (09) : 1679 - 1684
  • [38] Effects of framing coil shape, orientation, and thickness on intra-aneurysmal flow
    Jeong, Woowon
    Han, Moon Hee
    Rhee, Kyehan
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2013, 51 (09) : 981 - 990
  • [39] Impact of stent design on intra-aneurysmal flow -: A computer simulation study
    Ohta, M
    Hirabayashi, M
    Wetzel, S
    Lylyk, P
    Wata, H
    Tsutsumi, S
    Rüfenacht, DA
    INTERVENTIONAL NEURORADIOLOGY, 2004, 10 : 85 - 94
  • [40] Endovascular treatment of pseudoaneurysm of the common hepatic artery with intra-aneurysmal glue (N-butyl 2-cyanoacrylate) embolization
    Garg, Ashwin
    Banait, Swati
    Babhad, Sudeep
    Kanchankar, Niraj
    Nimade, Pradeep
    Panchal, Chintan
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2007, 30 (05) : 999 - 1002