Blood Pressure Measurements using Non-contact Video Imaging Techniques

被引:0
|
作者
Khong, Wei Leong [1 ]
Rao, Nittala Surya Venkata Kameswara [1 ]
Mariappan, Muralindran [1 ]
机构
[1] Univ Malaysia Sabah, Fac Engn, Kota Kinabalu, Sabah, Malaysia
关键词
Blood Pressure; Health Monitoring; Non-Contact; Pulse Wave Velocity; Video Imaging;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Health is always used to describe a person's conditions. To stay healthy, regular in monitoring physiological parameters are unavoidable. In this study, non-contact video imaging techniques are proposed for blood pressure measurements whereas commercial oscillometric device is used for results verifications. Besides, the proposed techniques also able to obtain the pulse rate simultaneously. From the results, it shows the mean absolute error and standard deviation for systolic and diastolic blood pressure is 4.22 +/- 3.15mmHg and 3.24 +/- 2.21mmHg respectively. On the other hand, pulse rate measurements also achieved a good agreement with the oscillometric device. These results are fulfilled the requirements of American National Standard which is 5 +/- L8mmHg for blood pressure and +/- 5bpm or 10% allowable readout error for pulse rate measurements. As a conclusion, the developed non-contact techniques are suitable to continuously and regularly monitor blood pressure and pulse rate simultaneously without a break between the measurements like the standard cuff-based devices.
引用
收藏
页码:35 / 40
页数:6
相关论文
共 50 条
  • [1] Fair non-contact blood pressure estimation using imaging photoplethysmography
    Fang, Hongli
    Xiong, Jiping
    He, Linying
    [J]. BIOMEDICAL OPTICS EXPRESS, 2024, 15 (04): : 2133 - 2151
  • [2] Non-contact method of blood pressure estimation using only facial video
    Ryo Takahashi
    Keiko Ogawa-Ochiai
    Norimichi Tsumura
    [J]. Artificial Life and Robotics, 2020, 25 : 343 - 350
  • [3] Non-contact method of blood pressure estimation using only facial video
    Takahashi, Ryo
    Ogawa-Ochiai, Keiko
    Tsumura, Norimichi
    [J]. ARTIFICIAL LIFE AND ROBOTICS, 2020, 25 (03) : 343 - 350
  • [4] Non-contact, automated cardiac pulse measurements using video imaging and blind source separation
    Poh, Ming-Zher
    McDuff, Daniel J.
    Picard, Rosalind W.
    [J]. OPTICS EXPRESS, 2010, 18 (10): : 10762 - 10774
  • [5] Non-Contact Blood Pressure Estimation Using Video Pulse Waves for Ubiquitous Health Monitoring
    Yoshizawa, Makoto
    Sugita, Norihiro
    Abe, Makoto
    Tanaka, Akira
    Homma, Noriyasu
    Yambe, Tomoyuki
    [J]. 2017 IEEE 6TH GLOBAL CONFERENCE ON CONSUMER ELECTRONICS (GCCE), 2017,
  • [6] Non-contact Continuous Blood Pressure Measurement Based on Imaging Equipment
    Guo, Ying
    Liu, Xiaohua
    Kong, Lingqin
    Liu, Ming
    Zhao, Yuejin
    Dong, Liquan
    [J]. 2019 INTERNATIONAL CONFERENCE ON OPTICAL INSTRUMENTS AND TECHNOLOGY: OPTOELECTRONIC IMAGING/SPECTROSCOPY AND SIGNAL PROCESSING TECHNOLOGY, 2020, 11438
  • [7] A non-contact continuous blood pressure measurement method based on video stream
    Yan H.
    Li X.
    Zhu T.
    Chen X.
    Gong N.
    Zhou Q.
    [J]. Shengwu Yixue Gongchengxue Zazhi/Journal of Biomedical Engineering, 2023, 40 (02): : 249 - 256
  • [8] Non-contact measurements using light
    Woppowa, L
    [J]. GEFAHRSTOFFE REINHALTUNG DER LUFT, 2000, 60 (7-8): : 273 - 274
  • [9] Non-Contact Blood Pressure Measurement Scheme Using Doppler Radar
    Ohata, Tomoyuki
    Ishibashi, Koichiro
    Sun, Guanghao
    [J]. 2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 778 - 781
  • [10] Non-contact Pulse Transit Time Measurement using Imaging Camera, and its Relation to Blood Pressure
    Murakami, Kenta
    Yoshioka, Mototaka
    Ozawa, Jun
    [J]. 2015 14th IAPR International Conference on Machine Vision Applications (MVA), 2015, : 414 - 417