Minor effect of inaccurate fixation on VEP-based acuity estimates

被引:3
|
作者
Elgohary, Amal A. [1 ]
Heinrich, Sven P. [2 ,3 ]
机构
[1] Res Inst Ophthalmol, Dept Vis Sci, Cairo, Egypt
[2] Univ Freiburg, Eye Ctr, Med Ctr, Killianstr 5, D-79106 Freiburg, Germany
[3] Univ Freiburg, Fac Med, Freiburg, Germany
关键词
Objective acuity testing; Visual evoked potentials; Eccentric fixation; Visual acuity; malingering; functional impairment; VISION;
D O I
10.1007/s10633-020-09796-7
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose VEP-based estimation of visual acuity may be used in cases of suspected malingering to objectify subjective complaints. In such an application, a lack of cooperation needs to be expected. The same may apply to young children with suspected functional impairments. In the present study, we assessed how inaccurate fixation affects the acuity estimates obtained with a VEP technique. Methods VEP-based acuity estimates were obtained by stimulating with a series of different check sizes using a 'stepwise sweep' protocol. Sixteen participants were tested with normal and degraded vision under five different fixation conditions (central fixation and eccentric fixation at top, bottom, right, and left edge of the stimulus area). Results The majority of individual acuity estimates with eccentric fixation differed by less than 0.1 logMAR from central fixation, and almost all estimates differed by less than 0.3 logMAR. Median estimates with eccentric fixation differed only slightly (up to 0.08 logMAR) and, except for top fixation with normal vision, non-significantly. However, data quality was lower with eccentric fixation, which increased the probability that no acuity estimate could be derived from the recording. Conclusion VEP-based acuity estimates are relatively insensitive to eccentric fixation. Unnoticed deviations from central fixation in routine applications will probably be smaller than in the present study and will have even less impact on the outcome.
引用
收藏
页码:275 / 282
页数:8
相关论文
共 50 条
  • [31] Investigating Flicker-Free Steady-State Motion Stimuli for VEP-Based BCIs
    Stawicki, Piotr
    Rezeika, Aya
    Saboor, Abdul
    Volosyak, Ivan
    2019 E-HEALTH AND BIOENGINEERING CONFERENCE (EHB), 2019,
  • [32] Objective Visual Acuity Estimates in Amblyopia Are More Accurate With Optotype-Based P300 Than With VEP Measurements
    Gopiswaminathan, Akshara, V
    Haldina, Julia
    Al-Nosairy, Khaldoon O.
    Duval, Celine Z.
    Stolle, Francie H.
    Hoffmann, Michael B.
    Heinrich, Sven P.
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2024, 13 (12):
  • [33] Steady state VEP-based BCI to control a five-digit robotic hand using LabVIEW
    Sandesh, R. S.
    Venkatesan, Nithya
    INTERNATIONAL JOURNAL OF BIOMEDICAL ENGINEERING AND TECHNOLOGY, 2022, 38 (02) : 109 - 127
  • [34] THE EFFECTS OF FIELD SIZE, TEMPORAL FREQUENCY AND SPATIAL-FREQUENCY RANGE ON SWEEP VEP ACUITY ESTIMATES
    HITCHCOX, SM
    HARTMANN, EE
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1992, 33 (04) : 833 - 833
  • [35] EFFECT OF FIXATION DISPARITY ON STEREO-ACUITY
    COLE, RG
    BOISVERT, RP
    AMERICAN JOURNAL OF OPTOMETRY AND PHYSIOLOGICAL OPTICS, 1974, 51 (03): : 206 - 213
  • [36] EFFECT OF FIXATION DISPARITY ON STEREO-ACUITY
    COLE, RG
    BOISVERT, D
    AMERICAN JOURNAL OF OPTOMETRY AND ARCHIVES OF AMERICAN ACADEMY OF OPTOMETRY, 1972, 49 (10): : 883 - &
  • [37] A Two-tier Comprehensive Evaluation Measure Model about VEP-Based on Fuzzy-AHP Method
    Bu, Huabai
    Gao, Yang
    ICOSCM 2009 - PROCEEDINGS OF THE 3RD INTERNATIONAL CONFERENCE ON OPERATIONS AND SUPPLY CHAIN MANAGEMENT, 2009, 3 : 14 - 18
  • [38] Dynamic time window mechanism for time synchronous VEP-based BCIs-Performance evaluation with a dictionary-supported BCI speller employing SSVEP and c-VEP
    Gembler, Felix
    Stawicki, Piotr
    Saboor, Abdul
    Volosyak, Ivan
    PLOS ONE, 2019, 14 (06):
  • [39] The effect of optotype presentation duration on acuity estimates revisited
    Sven P. Heinrich
    Katja Krüger
    Michael Bach
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2010, 248 : 389 - 394
  • [40] The effect of optotype presentation duration on acuity estimates revisited
    Heinrich, Sven P.
    Krueger, Katja
    Bach, Michael
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2010, 248 (03) : 389 - 394