Short Circuit Tests on a Coreless HTS Synchronous Generator

被引:6
|
作者
Bailey, W. O. S. [1 ]
Yang, Y. [1 ]
Beduz, C. [1 ]
Goddard, K. F. [2 ]
机构
[1] Univ Southampton, Fac Engn & Environm, Inst Cryogen, Southampton SO17 1BJ, Hants, England
[2] Univ Southampton, Sch Elect & Comp Sci, Southampton SO17 1BJ, Hants, England
关键词
Air-core rotors; high-temperature superconducting (HTS) machines; superconducting winding; synchronous machines;
D O I
10.1109/TASC.2013.2244196
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A series of short circuit tests have been performed on a coreless (air-core) high-temperature superconducting (HTS) rotor, installed inside a conventional stator. The machine was driven like a generator using an 11 kW drive motor, to a maximum frequency of 20 Hz. The short circuit was activated at the stator terminals using a three-phase contactor switch and a remote trigger. Tests were conducted with a range of values for each of the following parameters: i) initial frequency, between 4 and 20 Hz; ii) operating field current, between 5 and 80 A; and iii) external resistance, between 14 and 160 m Omega. For each investigation, the other parameters were fixed. Large current surges were observed in both the stator (3 times its nominal current) and in the rotor (1/4 of the initial operating current). Some localized thermal measurements of a coil in the HTS winding were also recorded but, during the transient events, these measurements are invalidated by inductive voltages. The temperature is believed to remain steady during the short circuit event. The rotational kinetic energy of this rotor was almost half of its counterpart, but it was the power supply and the series resistor that absorbed most of the magnetomotive energy after the short-circuit. These components are essential parts of the HTS generators' overall system and their operating limits must also be considered in new designs.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] NONLINEAR ANALYSIS OF SUDDEN THREE-PHASE SHORT-CIRCUIT OF A SYNCHRONOUS GENERATOR.
    Inoue, Yoshiaki
    Ueda, Yoshisuke
    Uenosono, Chikasa
    1600, (104):
  • [42] Online Condition Monitoring of Large Synchronous Generator under Short Circuit Fault-A Review
    Sadeghi, Iman
    Ehya, Hossein
    Faiz, Jawad
    Akmal, Amir Abbas Shayegani
    2018 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY (ICIT), 2018, : 1843 - 1848
  • [43] Parameter estimation of synchronous generator fault of short-circuit based on expansion Prony algorithm
    Liu, Li-Yan
    Zhu, Lin
    Zeng, Zhe-Zhao
    Dianji yu Kongzhi Xuebao/Electric Machines and Control, 2008, 12 (04): : 420 - 424
  • [44] On Estimation of the Shock Current of a Powerful Synchronous Generator Based on the Results of a Sudden Short Circuit Experiment
    A. I. Sudakov
    I. R. Ziyatdinov
    D. V. Falaleev
    Russian Electrical Engineering, 2024, 95 (11) : 927 - 929
  • [45] Effect of the magnet shape on the performance of coreless axial flux permanent magnet synchronous generator
    Amin, Shahbaz
    Madanzadeh, Sadjad
    Khan, Sahib
    Bukhari, Syed Sabir Hussain
    Akhtar, Faheem
    Ro, Jong-Suk
    ELECTRICAL ENGINEERING, 2022, 104 (02) : 959 - 968
  • [46] Effect of the magnet shape on the performance of coreless axial flux permanent magnet synchronous generator
    Shahbaz Amin
    Sadjad Madanzadeh
    Sahib Khan
    Syed Sabir Hussain Bukhari
    Faheem Akhtar
    Jong-Suk Ro
    Electrical Engineering, 2022, 104 : 959 - 968
  • [47] HTS synchronous machine critical current modelling and comparison with tests
    O'Brien, P. G.
    Taylor, R. R.
    14TH EUROPEAN CONFERENCE ON APPLIED SUPERCONDUCTIVITY (EUCAS2019), 2020, 1559
  • [48] Estimation of Short Circuit Capability of Generator Circuit Breaker For a Generator Fed Fault
    Chanda, K.
    Parthasarathi, R.
    Holla, S.
    2008 IEEE/PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXPOSITION: LATIN AMERICA, VOLS 1 AND 2, 2008, : 352 - 355
  • [49] The Design of a Lightweight HTS Synchronous Generator Cooled by Subcooled Liquid Nitrogen
    Bailey, Wendell O. S.
    Al-Mosawi, Maitham
    Yang, Yifeng
    Goddard, Kevin
    Beduz, Carlo
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2009, 19 (03) : 1674 - 1677
  • [50] Ensuring synchronous generator special standstill tests
    Vrazic, Mario
    Gasparac, Ivan
    Pavlica, Milutin
    ICEM: 2008 INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES, VOLS 1- 4, 2009, : 558 - 562