Contrast sensitivity after refractive lens exchange with diffractive multifocal intraocular lens implantation in hyperopic eyes

被引:30
|
作者
Ferrer-Blasco, Teresa [1 ]
Montes-Mico, Robert [1 ]
Cervino, Alejandro [1 ]
Alfonso, Jose F. [2 ,3 ]
Fernandez-Vega, Luis [2 ,3 ]
机构
[1] Univ Valencia, Fac Phys, Dept Opt, Optometry Res Grp, E-46100 Burjassot, Spain
[2] Univ Oviedo, Fernandez Vega Ophthalmol Inst, Sch Med, Oviedo, Spain
[3] Univ Oviedo, Dept Surg, Sch Med, Oviedo, Spain
来源
关键词
D O I
10.1016/j.jcrs.2008.06.046
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate distance and near contrast sensitivity under photopic and mesopic conditions before and after refractive lens exchange (RLE) with implantation of a diffractive multifocal intraocular lens (IOL). SETTING: University of Valencia, Valencia, Spain, METHODS: Monocular contrast sensitivity function was measured with the Functional Acuity Contrast Test chart at distance and near under 3 luminance levels (85.0 cd/m(2), 5.0 cd/m(2), and 2.5 cd/m(2)) before and after FILE with bilateral AcrySof ReSTOR IOL implantation in 30 hyperopic eyes with presbyopia and low astigmatism (<= 1.0 diopter). Results after surgery were compared with those before surgery. RESULTS: Six months postoperatively, the mean residual spherical equivalent refractive error was 0.21 diopter +/- 0.19 (SD). The best corrected distance and near visual acuities were comparable to those before surgery. For distance vision, the safety index was 1.02 and the efficacy index was 0.91. For near vision, the values were 1.04 and 1.02, respectively. There were no statistically significant differences between preoperative and postoperative results at any distance or spatial frequency or under any lighting condition (P >.1, t test). CONCLUSIONS: Refractive lens exchange with implantation of a diffractive multifocal IOL gave good distance and near contrast sensitivity under photopic and mesopic conditions. Although mesopic contrast sensitivity was reduced at distance and near compared to that under photopic conditions, the performance was comparable to that with the natural lens preoperatively.
引用
下载
收藏
页码:2043 / 2048
页数:6
相关论文
共 50 条
  • [21] Usefulness of Implantation of Diffractive Multifocal Intraocular Lens in Eyes with Long Axial Lengths
    Ogawa, Tomoichiro
    Shiba, Takuya
    Tsuneoka, Hiroshi
    JOURNAL OF OPHTHALMOLOGY, 2015, 2015
  • [22] Functional Outcomes After Refractive Lens Exchange With Implantation of a Glistening-Free Diffractive Trifocal Intraocular Lens
    Khoramnia, Ramin
    Naujokaitis, Tadas
    Baur, Isabella D.
    Hassel, Oliver
    Henningsen, Nikola
    Reitemeyer, Emanuel
    Chychko, Lizaveta
    Labuz, Grzegorz
    Auffarth, Gerd U.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2024, 268 : 296 - 305
  • [23] Refractive outcomes after bilateral multifocal intraocular lens implantation
    Pineda-Fernández, A
    Jaramillo, J
    Celis, V
    Vargas, J
    DiStacio, M
    Galíndez, A
    Del Valle, M
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (03): : 685 - 688
  • [24] Visual Outcomes and Patient Satisfaction after Refractive Lens Exchange with a Single-Piece Diffractive Multifocal Intraocular Lens
    Chang, John S. M.
    Ng, Jack C. M.
    Chan, Vincent K. C.
    Law, Antony K. P.
    JOURNAL OF OPHTHALMOLOGY, 2014, 2014
  • [25] Clear lens extraction with multifocal apodized diffractive intraocular lens implantation
    Fernandez-Vega, Luis
    Alfonso, Jose F.
    Rodriguez, Pedro P.
    Montes-Mico, Robert
    OPHTHALMOLOGY, 2007, 114 (08) : 1491 - 1498
  • [26] Piggyback Intraocular Lens Implantation to Correct Pseudophakic Refractive Error After Segmental Multifocal Intraocular Lens Implantation
    Venter, Jan A.
    Oberholster, Andre
    Schallhorn, Steven C.
    Pelouskova, Martina
    JOURNAL OF REFRACTIVE SURGERY, 2014, 30 (04) : 234 - 239
  • [27] Quality of vision after bilateral multifocal intraocular lens implantation in pregeriatric Hispanic population, after refractive lens exchange
    Alberto Nava, Jose
    Rubi Morales-Mancillas, Nallely
    Valdez, Jorge E.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [28] Threshold limit of postoperative astigmatism for patient satisfaction after refractive lens exchange and multifocal intraocular lens implantation
    McNeely, Richard N.
    Pazo, Eric
    Millar, Zack
    Richoz, Olivier
    Nesbit, Andrew
    Moore, Tara C. B.
    Moore, Jonathan E.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (08): : 1126 - 1134
  • [29] Visual performance after implantation of an aspheric multifocal diffractive intraocular lens
    Akaishi, Leonardo
    Messias, Camila Brito
    de Moraes Tzelikis, Patrick Frensel
    REVISTA BRASILEIRA DE OFTALMOLOGIA, 2010, 69 (04) : 230 - 235
  • [30] Diffractive multifocal intraocular lens implantation in patients with monofocal intraocular lens in the contralateral eye
    Jae Yong Kim
    Yunhan Lee
    Hun Jae Won
    Hyerin Jeong
    Jin Hyoung Park
    Myoung Joon Kim
    Hungwon Tchah
    International Journal of Ophthalmology, 2020, (05) : 737 - 743