ANALYSIS OF AIRBORNE DUST AS A RESULT OF PLASTER CAST SAWING

被引:3
|
作者
Antabak, Anko [1 ,2 ]
Haluzan, Damir [1 ,2 ]
Chouehne, Abdulah [2 ]
Mance, Marko [3 ]
Fuchs, Nino [3 ]
Prlic, Ivica [4 ]
Beslic, Ivan [4 ]
Klaic, Zvjezdana Bencetic [5 ]
机构
[1] Univ Zagreb, Dept Surg, Zagreb Univ Hosp Ctr, Kispaticeva 12, HR-10000 Zagreb, Croatia
[2] Univ Zagreb, Sch Med, Kispaticeva 12, HR-10000 Zagreb, Croatia
[3] Zagreb Univ Hosp Ctr, Dept Surg, Zagreb, Croatia
[4] Inst Med Res & Occupat Hlth, Zagreb, Croatia
[5] Univ Zagreb, Andrija Mohorovicic Geophys Inst, Dept Geophys, Fac Sci, Zagreb, Croatia
关键词
Casts; surgical; Calcium sulfate; Air pollutants - toxicity; Orthopedic fixation devices; Dust - adverse effects; OUTDOOR;
D O I
10.20471/acc.2017.56.04.04
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Plaster splints are used daily in surgical and orthopedic fields in order to immobilize injured children and adults. The aim of this study was to measure the aerodynamic diameter and concentration of dust particles in the air caused by sawing plaster splints (calcium sulfate dehydrate). We performed fractional measurements of airborne dust particles. The measured particles, which can potentially be inhaled, may have a specific negative effect on human health. Measurements were conducted in laboratory research facilities that simulated hospital conditions within a casting room and the associated waiting room. Measurements within the casting room were made using two particle collector devices and one laser photometer. The measurement for the simulated waiting room was performed using the same principles and devices. The collected plaster dust particles differed in aerodynamic diameter and concentration according to the various locations observed. The highest concentration of particles of all sizes was recorded at the site of cast sawing. There was direct correlation between distance from the source and concentration of airborne particles; this concentration was lowest in the waiting room. The concentrations of plaster dust recorded were lower than the recommended minimal limit values for total and respiratory fractions in Croatia. Accordingly, it can be assumed that sawing of plaster splints has no harmful health effects on the exposed patients and health personnel.
引用
收藏
页码:600 / 608
页数:9
相关论文
共 50 条
  • [41] Comparison of different digestion methods for elemental analysis of airborne dust and dust deposition
    Lumpp, R.
    Klein, M.
    Bieber, E.
    Bunzel, F.
    Eckermann, U.
    Frels, C.
    Guenther, W.
    Hagemann, C.
    Koch, C.
    Olschewski, A.
    Temme, C.
    GEFAHRSTOFFE REINHALTUNG DER LUFT, 2012, 72 (1-2): : 64 - 71
  • [42] VASCULAR COMPRESSION OF THE DUODENUM ASSOCIATED WITH A BODY PLASTER CAST (THE CAST SYNDROME)
    DETOLEDO, JMO
    LORENZO, FG
    DOMINGUEZ, J
    CIMADEVILA, J
    BERNARDEZ, J
    FERNANDEZ, PY
    REVISTA ESPANOLA DE ENFERMEDADES DIGESTIVAS, 1993, 83 (01) : 38 - 41
  • [43] An Indoor Airflow Simulation and Airborne Dust Concentration Analysis
    Yu, Anyang
    Zhao, Haonan
    Zhang, Changjiang
    Meng, Yu
    PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON COMPUTER MODELING AND SIMULATION (ICCMS 2018), 2017, : 265 - 270
  • [44] APPLICATION OF PIXE TO THE ELEMENT-ANALYSIS OF AIRBORNE DUST
    RICHTER, FW
    ANNALEN DER PHYSIK, 1985, 42 (03) : 239 - 249
  • [45] RULES FOR SURVEILLANCE OF A PATIENT WEARING A PLASTER CAST
    BONFAIT, H
    GAGEY, O
    REVUE DU PRATICIEN, 1983, 33 (52): : 2817 - 2820
  • [46] Properties of a hybrid plaster-fibreglass cast
    Charles, MN
    Yen, D
    CANADIAN JOURNAL OF SURGERY, 2000, 43 (05) : 365 - 367
  • [47] PLASTER CAST ARM RESTRAINTS AND AMBLYOPIA THERAPY
    HILES, DA
    GALKET, RJ
    JOURNAL OF PEDIATRIC OPHTHALMOLOGY, 1974, 11 (03): : 151 - 152
  • [48] BIOMECHANICAL EFFECTS OF ROCKERS ON WALKING IN A PLASTER CAST
    HULLIN, MG
    ROBB, JE
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (01): : 92 - 95
  • [49] Driving with a forearm plaster cast: patients' perspective
    Edwards, M. R.
    Oliver, M. C.
    Hatrick, N. C.
    EMERGENCY MEDICINE JOURNAL, 2009, 26 (06) : 405 - 406
  • [50] EFFECT OF PLASTER-CAST IMMOBILIZATION ON THE BONE
    FOLDES, I
    GYARMATI, J
    RAPCSAK, M
    SZOOR, A
    SZILAGYI, T
    ACTA PHYSIOLOGICA HUNGARICA, 1986, 67 (04) : 413 - 418