Membrane bioreactors in industrial wastewater treatment - European experiences, examples and trends

被引:35
|
作者
Cornel, P [1 ]
Krause, S [1 ]
机构
[1] Tech Univ Darmstadt, Inst WAR, D-64287 Darmstadt, Germany
关键词
mBR; design; pre-treatment; oxygen transfer; industrial applications;
D O I
10.2166/wst.2006.074
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In wastewater treatment, micro- and ultra-filtration membranes are used for the separation of the activated sludge (biomass) from the treated water. This offers the advantages of a complete removal of solids and bacteria, as well as most of the viruses, namely those attached to the suspended solids. Compared to the conventional activated sludge process (CAS) this technology allows a much higher biomass concentration (MLSS) whereby the reactor volume and the footprint decreases. With increasing MLSS, the viscosity of the sludge increases, which leads to reduced oxygen transfer rates. Depending on the type of membrane and membrane module, the pre-treatment has to be more sophisticated to prevent clogging and sludging of the modules. Due to fouling and scaling, the flux through the membranes will decrease with time. The decrease depends on the water quality as well as on the measurements taken to minimize fouling. Mainly, three strategies are available: lowering the flux, increasing the "crossflow" and cleaning of the membranes. Different strategies including backwash and chemical cleaning "in situ", "on air" and "ex situ" can be applied. It has been proven more effective to apply preventive regular cleaning. Besides the energy demand for oxygen supply - which is typically in the range of 0.3 kWh/m(3) for municipal wastewater - the energy for fouling prevention is substantial. Immersed membranes need approximately 0.4 to 1 kWh/m(3) -:or the coarse bubble aeration, whereas tubular modules require 1 to 4 kWh/m3 pump energy. For proper design of industrial wastewater treatment, the verification of applicability and the development of adequate cleaning strategies, it is a precondition to run pilot tests for a sufficient period of time with the wastewater to be treated. More than 100 industrial wastewater treatment membrane bioreactors (MBR) are in operation in Europe. Data of three case studies for a sewage sludge dewatering plant in UK (12,000 m(3)/d), a plant for the treatment of pharmaceutical wastewater in Germany (3,600 m(3)/d), as well for revamping of an chemical WWTP > 2,000 m(3)/d in Italy, are given. MBRs will be used in future wherever high quality effluent is required, because of a sensitive receiving water body or due to the fact of water reuse as process water. MBRs are a perfect pre-treatment in industrial applications when further treatment with nanofiltration or reverse osmosis is considered. The technique is advanced and can be applied both in municipal and industrial wastewater treatment. Higher operational costs must be balanced by superior effluent quality.
引用
下载
收藏
页码:37 / 44
页数:8
相关论文
共 50 条
  • [1] Membrane Bioreactors for Industrial Wastewater Treatment: A Critical Review
    Lin, Hongjun
    Gao, Weijue
    Meng, Fangang
    Liao, Bao-Qiang
    Leung, Kam-Tin
    Zhao, Leihong
    Chen, Jianrong
    Hong, Huachang
    CRITICAL REVIEWS IN ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2012, 42 (07) : 677 - 740
  • [2] Membrane bioreactors in wastewater treatment
    Peters, TA
    Günther, R
    Vossenkaul, K
    FILTRATION & SEPARATION, 2000, 37 (01): : 18 - 21
  • [3] Extractive polymeric membrane bioreactors for industrial wastewater treatment: Theory and practice
    Manetti, Marco
    Tomei, Maria Concetta
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2022, 162 : 169 - 186
  • [4] Membrane fouling in membrane bioreactors for wastewater treatment
    Chang, IS
    Le Clech, P
    Jefferson, B
    Judd, S
    JOURNAL OF ENVIRONMENTAL ENGINEERING, 2002, 128 (11) : 1018 - 1029
  • [5] Membrane bioreactors for treatment of galvanic wastewater
    Makisha, Nikolay
    XXII INTERNATIONAL SCIENTIFIC CONFERENCE: CONSTRUCTION THE FORMATION OF LIVING ENVIRONMENT (FORM-2019), 2019, 97
  • [6] Membrane bioreactors for final treatment of wastewater
    Galil, NI
    Sheindorf, C
    Stahl, N
    Tenenbaum, A
    Levinsky, Y
    WATER SCIENCE AND TECHNOLOGY, 2003, 48 (08) : 103 - 110
  • [7] Membrane separation bioreactors for wastewater treatment
    Visvanathan, C
    Ben Aim, R
    Parameshwaran, K
    CRITICAL REVIEWS IN ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2000, 30 (01) : 1 - 48
  • [8] Fouling in membrane bioreactors used in wastewater treatment
    Le-Clech, Pierre
    Chen, Vicki
    Fane, Tony A. G.
    JOURNAL OF MEMBRANE SCIENCE, 2006, 284 (1-2) : 17 - 53
  • [9] Dimensioning of membrane bioreactors for municipal wastewater treatment
    Wedi, Detlef
    Joss, Adriano
    WATER SCIENCE AND TECHNOLOGY, 2008, 57 (06) : 829 - 835
  • [10] Cost aspects of membrane bioreactors for wastewater treatment
    Makisha, N.
    Saveliev, O.
    Katella, S.
    INTERNATIONAL CONFERENCE ON SUSTAINABLE CITIES, 2018, 2018, 177