Retrograde Femoral Artery Stent-Graft Implantation for Treatment of Access-site Bleeding Following Transcatheter Aortic Valve Implantation

被引:0
|
作者
Sliman, Hussein [1 ]
Shiran, Avinoam [1 ]
Mannheim, Dallit [2 ]
Avraham, Eyal [3 ]
Karmeli, Ron [3 ]
Khader, Nader [1 ]
Zafrir, Barak [1 ]
Rubinshtein, Ronen [1 ]
Jaffe, Ronen [1 ]
机构
[1] Technion Israel Inst Technol, Rappaport Fac Med, Carmel Med Ctr, Dept Cardiol, Haifa, Israel
[2] Technion Israel Inst Technol, Rappaport Fac Med, Carmel Med Ctr, Dept Vasc Surg, Haifa, Israel
[3] Hadassah Hebrew Univ, Med Ctr, Dept Vasc Surg, Jerusalem, Israel
来源
ISRAEL MEDICAL ASSOCIATION JOURNAL | 2019年 / 21卷 / 05期
关键词
access-site complications; femoral artery; retrograde; stent graft; transcatheter aortic valve implantation (TAVI); VASCULAR COMPLICATIONS; MANAGEMENT; IMPACT;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Access-site bleeding is a common complication of transfemoral transcatheter aortic valve implantation (TAVI). Percutaneous stent-graft implantation within the femoral artery may achieve hemostasis and avert the need for more invasive surgical vascular repair; however, failure to advance a guidewire antegradely via the injured vessel may preclude stent delivery. While retrograde stent-graft delivery from the distal vasculature may potentially enable percutaneous control of bleeding, this approach has not been reported. Objectives: To assess the feasibility of a retrograde approach for stent-graft implantation in the treatment of access-site bleeding following transfemoral TAVI. Methods: A prospective TAVI registry was analyzed. Of 349 patients who underwent TAVI, transfemoral access was used in 332 (95%). Access-site injury requiring stent-graft implantation occurred in 56 (17%). In four patients (7%), antegrade wiring across the site of vascular injury was not possible and a retrograde approach for stent delivery was used. Results: Distal vascular access was achieved via the superficial femoral or profunda artery. Retrograde advancement of a polymer-coated 0.035" wire to the abdominal aorta, followed by stent-graft delivery to the common femoral artery, achieved hemostasis in all cases. During a median (interquartile range) follow-up period of 198 (618) days (range 46-2455) there were no deaths and no patient required additional vascular interventions. Conclusions: A retrograde approach for stent-graft delivery is feasible and allows percutaneous treatment of a common femoral artery injury following TAVI in patients who are not suitable for the conventional antegrade approach.
引用
收藏
页码:322 / 325
页数:4
相关论文
共 50 条
  • [41] Feasibility and Outcomes of Transcatheter Aortic Valve Implantation Using the Left Axillary Artery as Primary Access Site
    van der Wulp, Kees
    Verkroost, Michel W. A.
    van Wely, Marleen H.
    Gehlmann, Helmut R.
    Van Garsse, Leen A. F. M.
    Noyez, L.
    Brouwer, Marc A.
    Kievit, Peter C.
    De Boer, Menko-Jan
    Suryapranata, Harry
    Morshuis, Wim J.
    van Royen, Niels
    ANNALS OF THORACIC SURGERY, 2019, 107 (02): : 546 - 552
  • [42] Management of abdominal aortic and iliac artery aneurysms by stent-graft implantation in a patient on CAPD
    Polner, K.
    Gosi, G.
    Vas, S. I.
    Kalina, I.
    Acsady, G.
    CLINICAL NEPHROLOGY, 2009, 71 (03) : 359 - 362
  • [43] Access Site Complications of Transcatheter Aortic Valve Implantation: Ataturk Hospital Experience
    Sari, Cenk
    Keles, Telat
    Durmaz, Tahir
    Aslan, Abdullah Nabi
    Bastug, Serdal
    Ayhan, Huseyin
    Akcay, Murat
    Bilen, Emine
    Bayram, Nihal Akar
    Cicek, Omer Faruk
    Ozen, Mehmet Burak
    Kasapkara, Haci Ahmet
    Bozkurt, Engin
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 62 (18) : C32 - C33
  • [44] A systematic review of transcatheter aortic valve implantation via carotid artery access
    Stonier, Thomas
    Harrison, Michael
    Choong, Andrew M. T. L.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2016, 219 : 41 - 55
  • [45] Left ventricular stent-graft implantation for severe left ventricular outflow tract obstruction after transcatheter mitral valve implantation
    Ruge, Hendrik
    Krane, Markus
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2024, 66 (02)
  • [46] Aortic dissection: stent-graft implantation by intravascular ultrasound guidance
    Koschyk, DH
    Dieckmann, C
    Wolf, W
    Meinertz, T
    Nienaber, CA
    EUROPEAN HEART JOURNAL, 2000, 21 : 142 - 142
  • [47] Helical CT after aortic stent-graft implantation - Reply
    Golzarian, J
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (06) : 1690 - 1691
  • [48] Transesophageal echocardiographic guidance of thoracic aortic stent-graft implantation
    Schütz, W
    Gauss, A
    Meierhenrich, R
    Pamler, R
    Görich, J
    JOURNAL OF ENDOVASCULAR THERAPY, 2002, 9 : 14 - 19
  • [49] Cardiac resynchronization therapy implantation following transcatheter aortic valve implantation
    Osmancik, Pavel
    Stros, Petr
    Herman, Dalibor
    Kocka, Viktor
    Paskova, Eva
    EUROPACE, 2011, 13 (02): : 290 - 291
  • [50] Transcatheter aortic valve implantation: alternative access options
    Schirmer, J.
    Conradi, L.
    Seiffert, M.
    Koschyk, D.
    Blankenberg, S.
    Reichenspurner, H.
    Diemert, P.
    Treede, H.
    MINERVA CARDIOANGIOLOGICA, 2013, 61 (04): : 429 - 435