Top-down model for dynamic simulation of cold-storage plants

被引:13
|
作者
Hasse, H
Becker, M
Grossmann, K
Maurer, G
机构
[1] UNIV KAISERSLAUTERN,LEHRSTUHL TECH THERMODYNAM,D-67653 KAISERSLAUTERN,GERMANY
[2] UNIV KAISERSLAUTERN,LEHRSTUHL AUTOMAT TECH,D-67653 KAISERSLAUTERN,GERMANY
[3] UNIV KAISERSLAUTERN,ZENTRUM MIKROELEKT,D-67653 KAISERSLAUTERN,GERMANY
关键词
thermodynamics; refrigeration plant; dynamic model; automation; control; simulation; experimental data;
D O I
10.1016/0140-7007(95)00077-1
中图分类号
O414.1 [热力学];
学科分类号
摘要
A simulation model for dynamic processes in cold-storage plants is presented. It consists of interacting subsystems like the cold-store air, goods, room structures, cold-store walls, evaporator, refrigerator and environment. The mathematical description is based on mass and energy balances, coupled with simple assumptions on heat and mass transfer. Freezing of goods and frosting of the evaporator is accounted for, as well as the possibility of defrosting. A concise description of the overall dynamic behaviour is achieved by using a modular structure together with top-down modelling. An advantage of this model is its limited number of parameters, most of which can be determined from readily available information, e.g. from data sheets. Using these parameters, the transient behaviour of the most important variables in cold-store operation can be predicted. Such predictions are compared to experimental data taken in the present work in a medium-size cold store. The transient behaviour of the temperature and relative humidity in that cold store is reported for a cooling period with two different controllers and for a defrosting period. For all studied operating conditions the results of the simulation show favourable agreement with the experimental data. This shows that the simulation model is suited for studies of improved automation and control concepts for for example, at preventing losses in the quality of the goods or for energy savings.
引用
收藏
页码:10 / 18
页数:9
相关论文
共 50 条
  • [21] THE TOP-DOWN REFLOODING MODEL IN THE CATHARE CODE
    BARTAK, J
    BESTION, D
    HAAPALEHTO, T
    NUCLEAR ENGINEERING AND DESIGN, 1994, 149 (1-3) : 141 - 152
  • [22] SIMULATION OF THE TRANSIENT REFRIGERATION LOAD IN A COLD-STORAGE FOR APPLES AND PEARS
    ADRE, N
    HELLICKSON, ML
    TRANSACTIONS OF THE ASAE, 1989, 32 (03): : 1038 - 1048
  • [23] Dynamic formulation of a top-down and bottom-up merging energy policy model
    Frei, CW
    Haldi, PA
    Sarlos, G
    ENERGY POLICY, 2003, 31 (10) : 1017 - 1031
  • [24] Process planning dynamic model based on HOOPN for top-down collaborative assembly design
    Yang, Y. D.
    Li, Z. H.
    Zhang, S. T.
    MATERIALS AND PRODUCT TECHNOLOGIES, 2008, 44-46 : 215 - +
  • [25] COLD-STORAGE AND EFFICIENT CONVERSION OF SOMATIC CELERY EMBRYOS INTO TRANSPLANTABLE PLANTS
    NADEL, BL
    ALTMAN, A
    ZIV, M
    SCIENTIA HORTICULTURAE, 1990, 44 (1-2) : 9 - 16
  • [26] Visual top-down attention framework for robots in dynamic environments
    Kaufmann, Ulrich
    Palm, Guenther
    EUROPEAN ROBOTICS SYMPOSIUM 2008, 2008, 44 : 323 - 332
  • [27] Top-down separation technologies targeting proteome dynamic range
    Wang, Yueju
    Cooper, Jonathan W.
    Balgley, Brian M.
    Rudnick, Paul
    Baehrecke, Eric H.
    DeVoe, Donald L.
    Lee, Cheng S.
    MOLECULAR & CELLULAR PROTEOMICS, 2004, 3 (10) : S289 - S289
  • [28] Top-down Modularization Using Extensible Skeleton Model
    Deng Ping
    Zhang Meng
    Wu Bao-zhong
    Gong Jing-zhong
    Li Guo-xi
    APPLIED MECHANICS AND MECHANICAL ENGINEERING II, PTS 1 AND 2, 2012, 138-139 : 210 - 216
  • [29] A Top-Down Spatially Resolved Electrical Load Model
    Robinius, Martin
    ter Stein, Felix
    Schwane, Adrien
    Stolten, Detlef
    ENERGIES, 2017, 10 (03):
  • [30] A model of top-down gain control in the auditory system
    Schneider, Bruce A.
    Parker, Scott
    Murphy, Dana
    ATTENTION PERCEPTION & PSYCHOPHYSICS, 2011, 73 (05) : 1562 - 1578