The Functional Mechanics of the Acetabular Component in Total Hip Arthroplasty

被引:7
|
作者
Bodner, Russell J. [1 ,2 ]
机构
[1] Northwestern Univ, Dept Orthoped Surg, Reg Med Grp, Chicago, IL 60611 USA
[2] Northwestern Univ, Feinberg Sch Med, Dept Orthoped Surg, Reg Med Grp, 2111 Midlands Court, Sycamore, IL 60178 USA
来源
JOURNAL OF ARTHROPLASTY | 2022年 / 37卷 / 11期
关键词
spinopelvic relationship; functional cup positioning; acetabular biomechanics; THA planning; personalized hip replacement; SPINAL DEFORMITY; PELVIC TILT; SPINOPELVIC MOBILITY; ORIENTATION; IMPINGEMENT; ALIGNMENT; POSITION; INSTABILITY; ANTEVERSION; ANATOMY;
D O I
10.1016/j.arth.2022.05.017
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Total hip arthroplasty functional safe zones match postural hip changes to dynamic positioning of the acetabular component. We studied integrating the Anteinclination (AI) cup angle into the spinopelvic environment, defining normative values for all parameters and calculating adjustments to AI for each degree of altered standing pelvic position and postural mobility from these values. A sagittal geometric model was employed to determine these values using established spinopelvic parameter angles.Methods: Theoretical normative Pelvic Incidence (PI) specific values were calculated using a triangular construct employing a linear equation describing the functional relationship between the pelvic parameters at a mobility producing an isosceles solution for normative acetabular angles. Individual optimal AI cup values for altered Sacral Slope (SS)/pelvic tilt (sPT) and mobility (dSS) were calculated using specific ratios of angular change between parameters correcting from these normative values.Results: A PI:SS:sPT ratio of angular change of 3:2:1 at dSS = 25 degrees mobility creates an isosceles condition solving for PI specific theoretical normative values for all construct parameters. Individualized tilt correction applies to each posture a +0.25 degrees AI alteration for each +1 degrees sPT increase from this architectural value. Mobility correction applies a +0.5 degrees standing AI and -0.5 degrees sitting AI alteration for each -1 degrees dSS < 25 degrees, the opposite for each +1 degrees dSS > 25 degrees. The Sacroacetabular angle/ Pelvic acetabular angle (SAA/PAA) index describes the underlying spinopelvic environment the cup functions within.Conclusion: This model quantitatively integrates an implanted acetabular component into the host spinopelvic environment. Theoretical normative and individual optimal cup orientations are passively determined by these conditions of standing pelvic position and mobility. (c) 2022 Elsevier Inc. All rights reserved.
引用
收藏
页码:2199 / +
页数:10
相关论文
共 50 条
  • [21] Effect of acetabular component anteversion on dislocation mechanisms in total hip arthroplasty
    Higa, Masaru
    Tanino, Hiromasa
    Abo, Masayoshi
    Kakunai, Satoshi
    Banks, Scott A.
    [J]. JOURNAL OF BIOMECHANICS, 2011, 44 (09) : 1810 - 1813
  • [22] Catastrophic Wear of an Acetabular Component Misdiagnosed as Total Hip Arthroplasty Dislocation
    Papaioannou, Ioannis
    Pantazidou, Georgia
    Chatziperi, Stamatia
    Baikousis, Andreas
    Korovessis, Panagiotis
    [J]. CUREUS JOURNAL OF MEDICAL SCIENCE, 2020, 12 (11)
  • [23] INCIDENCE AND MECHANISM OF FAILURE OF CEMENTED ACETABULAR COMPONENT IN TOTAL HIP ARTHROPLASTY
    EFTEKHAR, NS
    NERCESSIAN, O
    [J]. ORTHOPEDIC CLINICS OF NORTH AMERICA, 1988, 19 (03) : 557 - 566
  • [24] Fixation principles in total hip arthroplasty: Part 2 Acetabular component
    Breusch, SJ
    Aldinger, PR
    Thomsen, M
    Lukoschek, M
    Ewerbeck, V
    [J]. UNFALLCHIRURG, 2000, 103 (12): : 1017 - 1031
  • [25] Effect of Pelvic Obliquity on the Orientation of the Acetabular Component in Total Hip Arthroplasty
    Zhou, Xiaoxiao
    Wang, Qi
    Zhang, Xianlong
    Chen, Yunshu
    Shen, Hao
    Jiang, Yao
    [J]. JOURNAL OF ARTHROPLASTY, 2012, 27 (02): : 299 - 304
  • [26] Body mass index and acetabular component position in total hip arthroplasty
    McBride, Andrew
    Flynn, Jennifer
    Miller, George
    Barnes, Matthew
    Mackie, Scott
    [J]. ANZ JOURNAL OF SURGERY, 2013, 83 (03) : 171 - 174
  • [27] CEMENTLESS FIXATION OF POLYETHYLENE ACETABULAR COMPONENT IN TOTAL HIP-ARTHROPLASTY
    MORSCHER, EW
    DICK, W
    KERNEN, V
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1982, 99 (04) : 223 - 230
  • [28] Revision arthroplasty of the hip - Acetabular component
    Gollwitzer, H.
    von Eisenhart-Rothe, R.
    Holzapfel, B. M.
    Gradinger, R.
    [J]. CHIRURG, 2010, 81 (04): : 284 - +
  • [29] Primary Total Hip Arthroplasty With a Spongy Metal Surface Acetabular Component for Hip Dysplasia
    Takigami, Iori
    Ito, Yoshiki
    Matsumoto, Kazu
    Ogawa, Hiroyasu
    Terabayashi, Nobuo
    Shimizu, Katsuji
    [J]. JOURNAL OF ARTHROPLASTY, 2013, 28 (01): : 172 - 177
  • [30] Total Hip Arthroplasty Functional Outcomes Are Independent of Acetabular Component Orientation When a Polyethylene Liner Is Used
    Bobman, Jacob T.
    Danoff, Jonathan R.
    Babatunde, Oladapo M.
    Zhu, Kaicen
    Peyser, Katie
    Geller, Jeffrey A.
    Gorroochurn, Prakash
    Macaulay, William
    [J]. JOURNAL OF ARTHROPLASTY, 2016, 31 (04): : 830 - U209