Retention of CAD/CAM All-Ceramic Crowns on Prefabricated Implant Abutments: An In Vitro Comparative Study of Luting Agents and Abutment Surface Area

被引:35
|
作者
Carnaggio, Thomas V.
Conrad, Robert
Engelmeier, Robert L. [1 ]
Gerngross, Peter [2 ]
Paravina, Rade [3 ]
Perezous, Leticia [4 ]
Powers, John M. [3 ]
机构
[1] Univ Pittsburgh, Sch Dent Med, Dept Prosthodont, Pittsburgh, PA USA
[2] Michael E DeBakey VA Med Ctr, VADER Practice Based Res Network, Houston, TX USA
[3] Univ Texas Houston, Dent Branch, Dept Restorat Dent & Biomat, Houston, TX USA
[4] Univ Texas Houston, Dent Branch, Dept Prosthodont, Houston, TX USA
关键词
CAD; CAM; dental implant abutments; dental cements; implant abutment surface area; CEMENTED GOLD CASTINGS; FIT;
D O I
10.1111/j.1532-849X.2012.00847.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: Previous studies considering retention of cast metal restorations to implant abutments incorporated some degree of frictional fit due to internal surface nodules and roughness of the restoration. In comparison, CAD/CAM restorations have minimal surface irregularities, possibly impacting retention. There is insufficient knowledge of retentive force of CAD/CAM restorations to titanium abutments, and therefore the topic warrants further investigation. This in vitro study investigated the retention of all-ceramic CAD/CAM restorations to three different prefabricated implant abutments using five different cements. Materials and Methods: A total of 150 Astra Tech dental implant abutments were used, with each group of 50 being subdivided into five groups of 10. An optical impression of each size of abutment was made with the CEREC 3D intraoral camera. A full-coverage restoration was designed and milled with an enlarged, conical-shaped occlusal surface, which served to secure the restoration into a brass jig used with a universal testing machine. Five different cements were used with three different-sized abutments. Following cementation, the implant/abutment/restoration assemblies were stored for 24 hours at 37 degrees C in 100% humidity. A pull-out test using a universal testing machine, set at a 0.5 mm/min crosshead speed, was used to evaluate retention of the individual restorations. The load required to remove each all-ceramic restoration was recorded. Retention values were analyzed using ANOVA and Fisher's PLSD multiple comparisons test at the 0.05 level of significance. Results: Peak loads for two provisional cements and a resin-modified glass ionomer cement ranged from 56 N to 127 N. Peak loads for two resin cements ranged from 184 N to 318 N. Two-way ANOVA showed significant effects upon retentive forces for both the cement and abutment design. Post hoc Fisher's PLSD multiple comparisons test found significant differences in retention for 7 of the 10 pairings of cements at a 0.05 level of significance. In addition, Fisher's PLSD multiple comparisons test found significant differences between Astra Tech Direct Abutments 4 and Astra Tech Direct Abutments 5 as well as Astra Tech Direct Abutments 4 and Astra Tech Direct Abutments 6 at a 0.05 level of significance. No significant difference was found between Astra Tech Direct Abutments 5 and Astra Tech Direct Abutments 6. Conclusions: Of the five cements tested, the most retrievable CAD/CAM restorations were luted with Temp Bond NE and Improv Temporary Cement. Resin-modified glass ionomer retentive forces were closer to those of the temporary cements than those of the permanent adhesive-resin cements. The abutment surface area became less important when using adhesive-resin cements. Retention of CAD/CAM all-ceramic restorations to prefabricated abutments has not been reported in the literature. This in vitro study demonstrated clinically significant variation among the selected cements used to retain all-ceramic CAD/CAM restorations to implant abutments. In addition, abutment size influenced the retention of all-ceramic CAD/CAM restorations.
引用
收藏
页码:523 / 528
页数:6
相关论文
共 36 条
  • [21] Retention of luting agents used for implant-supported restorations: A comparative In-Vitro study
    Aladag, A.
    Sahan, M. H.
    Akkus, N. O.
    Aktas, R.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2020, 23 (08) : 1073 - 1078
  • [22] Fatigue fracture resistance of titanium and chairside CAD-CAM zirconia implant abutments supporting zirconia crowns: An in vitro comparative and finite element analysis study
    Giner, Sergio
    Bartolome, Jose F.
    Gomez-Cogolludo, Pablo
    Castellote, Carlos
    Pradies, Guillermo
    JOURNAL OF PROSTHETIC DENTISTRY, 2021, 125 (03): : 503.e1 - 503.e9
  • [23] Longevity and risk factors of CAD-CAM manufactured implant-supported all-ceramic crowns - A prospective, multi-center, practice-based cohort study
    Wierichs, R.J.
    Kramer, E.J.
    Reiss, B.
    Roccuzzo, A.
    Raabe, C.
    Yilmaz, B.
    Abou-Ayash, S.
    Dental Materials, 2024, 40 (11) : 1962 - 1969
  • [24] Polymer-Based Bioactive Luting Agents for Cementation of All-Ceramic Crowns: An SEM, EDX, Microleakage, Fracture Strength, and Color Stability Study
    Al-Saleh, Samer
    Aboghosh, Turki W.
    Hazazi, Mousa S.
    Binsaeed, Khalid A.
    Almuhaisen, Abdulaziz M.
    Tulbah, Huda I.
    Al-Qahtani, Amal S.
    Shabib, Sara
    Binhasan, Mashael
    Vohra, Fahim
    Abduljabbar, Tariq
    POLYMERS, 2021, 13 (23)
  • [25] In vitro chipping behaviour of all-ceramic crowns with a zirconia framework and feldspathic veneering: comparison of CAD/CAM-produced veneer with manually layered veneer
    Schmitter, M.
    Mueller, D.
    Rues, S.
    JOURNAL OF ORAL REHABILITATION, 2013, 40 (07) : 519 - 525
  • [26] Eleven-Year Follow-Up of a Prospective Study of Zirconia Implant Abutments Supporting Single All-Ceramic Crowns in Anterior and Premolar Regions
    Zembic, Anja
    Philipp, Alexander Otto Hermann
    Haemmerle, Christoph Hans Franz
    Wohlwend, Arnold
    Sailer, Irena
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2015, 17 : E417 - E426
  • [27] The in-vitro clinical failure of all-ceramic crowns and the connector area of fixed partial dentures: the influence of interfacial surface roughness
    Fleming, GJP
    Nolan, L
    Harris, JJ
    JOURNAL OF DENTISTRY, 2005, 33 (05) : 405 - 412
  • [28] Microleakage assessment of CAD-CAM Cobalt-Chrome and Zirconia abutments on a conical connection dental implant: A comparative in vitro study
    Molinero-Mourelle, Pedro
    Roccuzzo, Andrea
    Yilmaz, Burak
    Lam, Walter Yu Hang
    Pow, Edmond H. N.
    Highsmith, Jaime Del Rio
    Gomez-Polo, Miguel
    CLINICAL ORAL IMPLANTS RESEARCH, 2022, 33 (09) : 945 - 952
  • [29] Internal fit and marginal adaptation of all-ceramic implant-supported hybrid abutment crowns with custom-milled screw-channels on Titanium-base: in-vitro study
    Fakhr, Marwa Wagih Zaky Fouad
    Alansary, Hesham
    Hassanien, Eman Ezzat Youssef
    BMC ORAL HEALTH, 2024, 24 (01):
  • [30] Mechanical Performance of Chairside Ceramic CAD/CAM Restorations and Zirconia Abutments with Different Internal Implant Connections: In Vitro Study and Finite Element Analysis
    Giner, Sergio
    Bartolome, Jose F.
    Gomez-Cogolludo, Pablo
    Castellote, Carlos
    Pradies, Guillermo
    MATERIALS, 2021, 14 (17)