The application of multifunctional digital relays to protect medium voltage power transformers has become a common industrial practice. Industrial transformers, unlike utility transformers, frequently use neutral grounding resistors to limit ground current during faults to the 200400 A range on medium voltage systems. This article discusses why these types of transformers require sensitive ground differential protection. The basics of transformer protection are also reviewed, including phasing standards, through-fault withstand capability, differential/fusing/overcurrent protection, slope, current transformer (CT) requirements, and harmonic restraint. How to best communicate these requirements when programming and commissioning new digital relays is discussed. The rationale for providing transformer overexcitation protection on all major transformers within industrial facilities is also addressed. © 2012 IEEE.
引用
收藏
页码:63 / 73
页数:11
相关论文
共 50 条
  • [41] Study and Implementation of High Frequency Cast Resin Transformer Applied for Medium-Voltage Solid-State Transformer
    Chen, Kuan-Ting
    Chen, Jiann-Fuh
    Wang, Tsung-Jen
    Liao, Hsuan
    [J]. 2021 IEEE INTERNATIONAL FUTURE ENERGY ELECTRONICS CONFERENCE (IFEEC), 2021,
  • [42] A new wireless communication platform for medium-voltage protection and control
    Thonet, G
    Deck, BR
    [J]. WFCS 2004: IEEE INTERNATIONAL WORKSHOP ON FACTORY COMMUNICATION SYSTEMS, PROCEEDINGS, 2004, : 335 - 338
  • [43] Combined Protection and Control Equipment for Applications in the Medium-Voltage Area
    Dobriceanu, M.
    Bitoleanu, A.
    Popescu, M.
    Subtirelu, E.
    Enache, S.
    [J]. 2008 INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS, ELECTRICAL DRIVES, AUTOMATION AND MOTION, VOLS 1-3, 2008, : 860 - 865
  • [44] Maximizing Protection by Minimizing Arcing Times in Medium-Voltage Systems
    Kay, John A.
    Kumpulainen, Lauri
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2013, 49 (04) : 1920 - 1927
  • [45] Protection, metering, monitoring, and control of medium-voltage power systems
    Duncan, BK
    Bailey, BG
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2004, 40 (01) : 33 - 40
  • [46] GAS-INSULATED, MEDIUM-VOLTAGE SWITCH DISCONNECTOR PACKAGES FOR TRANSFORMER SUBSTATIONS
    MULLER, GCJ
    [J]. BROWN BOVERI REVIEW, 1985, 72 (12): : 586 - 591
  • [48] A Modular Front-End Medium-Voltage Solid-State Transformer
    Lai, Jih-Sheng
    Choe, Jung Muk
    Yeh, Chih-Shen
    Moon, Seung-Ryul
    Lai, Wei-Han
    Zhang, Lanhua
    [J]. 2017 ASIAN CONFERENCE ON ENERGY, POWER AND TRANSPORTATION ELECTRIFICATION (ACEPT), 2017,
  • [49] New protection principles for power transformer protection
    Ou, Zaojun
    He, J. H.
    Zhang, Biao
    [J]. PROCEEDINGS OF THE 41ST INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE, VOLS 1 AND 2, 2006, : 894 - 897
  • [50] A NEW MEDIUM-VOLTAGE ENERGY STORAGE CONVERTER TOPOLOGY WITH MEDIUM-FREQUENCY TRANSFORMER ISOLATION
    Krishnamoorthy, Harish. S.
    Garg, Pawan
    Enjeti, Prasad. N.
    [J]. 2012 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2012, : 3471 - 3478