Influence of configuration and anchor in ligamentous augmentation to prevent proximal junctional kyphosis: A finite element study

被引:0
|
作者
Liu, Wei [1 ]
Zang, Lei [1 ]
Kang, Nan [1 ]
Yang, Lihui [1 ]
An, Likun [1 ]
Zhu, Wenyi [1 ]
Hai, Yong [1 ]
机构
[1] Capital Med Univ, Beijing Chao Yang Hosp, Dept Orthoped Surg, Beijing, Peoples R China
关键词
adult spinal deformity; finite element; ligaments; proximal junctional kyphosis; tether; ADULT SPINAL DEFORMITY; THORACIC SPINE; PEDICLE SCREW; BIOMECHANICS; FUSION; MOTION; INSTRUMENTATION; CONSTRUCTS; SCOLIOSIS; OUTCOMES;
D O I
10.3389/fbioe.2022.1014487
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Ligament augmentation has been applied during spinal surgery to prevent proximal junctional kyphosis (PJK), but the configuration and distal anchor strategies are diverse and inconsistent. The biomechanics of different ligament augmentation strategies are, therefore, unclear. We aimed to create a finite element model of the spine for segments T6-S1. Model Intact was the native form, and Model IF was instrumented with a pedicle screw from segments T10 to S1. The remaining models were based on Model IF, with ligament augmentation configurations as common (CM), chained (CH), common and chained (CHM); and distal anchors to the spinous process (SP), crosslink (CL), and pedicle screw (PS), creating SP-CH, PS-CHM, PS-CH, PS-CM, CL-CHM, CL-CH, and CL-CM models. The range of motion (ROM) and maximum stress on the intervertebral disc (IVD), PS, and interspinous and supraspinous ligaments (ISL/SSL) was measured. In the PS-CH model, the ROM for segments T9-T10 was 73% (of Model Intact). In the CL-CHM, CL-CH, CL-CM, PS-CM, and PS-CHM models, the ROM was 8%, 17%, 7%, 13%, and 30%, respectively. The PS-CH method had the highest maximum stress on IVD and ISL/SSL, at 80% and 72%, respectively. The crosslink was more preferable as the distal anchor. In the uppermost instrumented vertebrae (UIV) + 1/UIV segment, the CM was the most effective configuration. The PS-CH model had the highest flexion load on the UIV + 1/UIV segment and the CL-CM model provided the greatest reduction. The CL-CM model should be verified in a clinical trial. The influence of configuration and anchor in ligament augmentation is important for the choice of surgical strategy and improvement of technique.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Instrumentation techniques to prevent proximal junctional kyphosis and proximal junctional failure in adult spinal deformity correction-a systematic review of biomechanical studies
    Doodkorte, Remco J. P.
    Vercoulen, Timon F. G.
    Roth, Alex K.
    de Bie, Rob A.
    Willems, Paul C.
    SPINE JOURNAL, 2021, 21 (05): : 842 - 854
  • [22] Posterior Ligamentous Reinforcement of the Upper Instrumented Vertebrae +1 Does Not Decrease Proximal Junctional Kyphosis in Adult Spinal Deformity
    Iyer, Sravisht
    Lovecchio, Francis
    Elysee, Jonathan Charles
    Lafage, Renaud
    Steinhaus, Michael
    Schwab, Frank J.
    Lafage, Virginie
    Kim, Han Jo
    GLOBAL SPINE JOURNAL, 2020, 10 (06) : 692 - 699
  • [23] Multilevel Stabilization Screws Prevent Proximal Junctional Failure and Kyphosis in Adult Spinal Deformity Surgery: A Comparative Cohort Study
    Kaufmann, Ascher
    Claus, Chad
    Tong, Doris
    Hanson, Connor
    Carr, Daniel
    Houseman, Clifford
    Soo, Teck-Mun
    OPERATIVE NEUROSURGERY, 2022, 22 (03) : 150 - 157
  • [24] Ligament Augmentation With Mersilene Tape Reduces the Rates of Proximal Junctional Kyphosis and Failure in Adult Spinal Deformity
    Rodnoi, Pope
    Le, Hai
    Hiatt, Luke
    Wick, Joseph
    Barber, Joshua
    Javidan, Yashar
    Roberto, Rolando
    Klineberg, Eric O.
    NEUROSPINE, 2021, 18 (03) : 580 - 586
  • [25] The influence of ligament biomechanics on proximal junctional kyphosis and failure in patients with adult spinal deformity
    Blais, Micah
    Shahidi, Bahar
    Anderson, Brad
    O'Brien, Eli
    Moltzen, Courtney
    Iannacone, Tina
    Eastlack, Robert K.
    Mundis Jr, Gregory M.
    JOR SPINE, 2023,
  • [26] A Pilot Study on Posterior Polyethylene Tethers to Prevent Proximal Junctional Kyphosis After Multilevel Spinal Instrumentation for Adult Spinal Deformity
    Angevine, Peter D.
    OPERATIVE NEUROSURGERY, 2019, 16 (02) : 265 - 266
  • [27] Tension Parameters of Junctional Tethers in Proximal Junction Kyphosis: A Cadaveric Biomechanical Study
    O'Hehir, Mary Margaret
    O'Connor, Timothy E.
    Mariotti, Brandon L.
    Soliman, Mohamed A. R.
    Quiceno, Esteban
    Gupta, Munish C.
    Berven, Sigurd
    Pollina, John
    Polly, David W.
    Mullin, Jeffrey P.
    WORLD NEUROSURGERY, 2024, 182 : E798 - E806
  • [28] Proximal junctional kyphosis after adult spinal deformity operated patients with long fusion to the pelvis. Does the type of proximal anchor matter?
    Bourghli, Anouar
    Boissiere, Louis
    Larrieu, Daniel
    Pizones, Javier
    Alanay, Ahmet
    Pellise, Ferran
    Kleinstueck, Frank
    Obeid, Ibrahim
    EUROPEAN SPINE JOURNAL, 2024, 33 (07) : 2832 - 2839
  • [29] Multi-level Stabilization Screws Prevent Proximal Junctional Failure and Kyphosis in Adult Spinal Deformity Surgery: A Comparative Cohort Study
    Kaufmann, Ascher
    Claus, Chad F.
    Houseman, Clifford M.
    Tong, Doris
    Carr, Daniel A.
    Soo, Teck M.
    NEUROSURGERY, 2022, 68 : 72 - 72
  • [30] Incidence and Risk Factors for Proximal Junctional Kyphosis Results of a Multicentric Study of Adult Scoliosis
    Sebaaly, Amer
    Sylvestre, Clement
    El Quehtani, Yehya
    Riouallon, Guillaume
    Larrieu, Daniel
    Boussiere, Louis
    Steib, Jean Paul
    Roussouly, Pierre
    Wolff, Stephane
    Obeid, Ibrahim
    CLINICAL SPINE SURGERY, 2018, 31 (03): : E178 - E183