Impregnation Technique Provides Corrosion Protection to Grouted Post-Tensioning Tendons

被引:0
|
作者
Whitmore, David [1 ]
Lasa, Ivan [2 ]
机构
[1] Vector Corros Technol, Winnipeg, MB, Canada
[2] Florida Dept Transportat, Gainesville, FL USA
关键词
D O I
10.1051/matecconf/201819905008
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Thousands of bridge structures rely on grouted post-tensioning (PT) tendons. Problems with grouting techniques and grout materials have resulted in bridges with grout voids, chloride contaminated grout and soft grout. These problems have promoted corrosion and failure of post-tension tendons, some within 6 to 17 years of service. The Florida Department of Transportation (FDOT) has spent more than $55 million (USD) repairing 11 post-tensioned bridges to date. A cost-effective corrosion mitigation technique has been developed to minimize the corrosion of PT tendons and extend the service life of bridges which have grouting issues. This paper describes the development and implementation of this technique on grouted PT bridges.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Incorporation of Stress Time Dependence into Failure Projection Modeling of Corroding Bridge Post-Tensioning Tendons
    Hartt, William H.
    Theryo, Teddy S.
    [J]. CORROSION, 2020, 76 (11)
  • [42] Realistic assessment of damaged post-tensioning tendons for the conservation of existing bridges within the road and railway stock
    Vill, Markus
    Eichinger, Eva M.
    Kollegger, Johann
    [J]. IABSE CONFERENCE NEW DELHI, INDIA 2005: ROLE OF STRUCTURAL ENGINEERS TOWARDS REDUCTION OF POVERTY, 2005, : 149 - 156
  • [43] A new steel anchorage system for post-tensioning applications using carbon fibre reinforced plastic tendons
    Sayed-Ahmed, EY
    Shrive, NG
    [J]. CANADIAN JOURNAL OF CIVIL ENGINEERING, 1998, 25 (01) : 113 - 127
  • [44] Cyclic loading behavior on strengthened composite beams using external post-tensioning tendons (experimental study)
    Hassanin, Ahmed Ibrahim
    Shabaan, Hesham Fawzy
    Elsheikh, Ahmed Ibrahim
    [J]. STRUCTURES, 2021, 29 : 1119 - 1136
  • [45] Assessing Passivation and Corrosion of Post-tensioning Strand in Grouts Under Chloride Salt Exposure
    Shakouri, Mahmoud
    Abraham, Ojo Friday
    Vaddey, Naga Pavan
    [J]. SMART & SUSTAINABLE INFRASTRUCTURE: BUILDING A GREENER TOMORROW, ISSSI 2023, 2024, 48 : 927 - 939
  • [46] Post-punching behaviour of flat slabs strengthened with a new technique using post-tensioning
    Faria, Duarte M. V.
    Lucio, Valter J. G.
    Ramos, A. Pinho
    [J]. ENGINEERING STRUCTURES, 2012, 40 : 383 - 397
  • [47] Investigations on the protection effect of filling materials for post-tensioning systems under construction conditions
    Mietz, J.
    Burkert, A.
    Burkert, A.
    Eich, G.
    [J]. MATERIALS AND CORROSION-WERKSTOFFE UND KORROSION, 2006, 57 (11): : 843 - 851
  • [48] Acoustic Emissions Sensor and Fuzzy C-mean Clustering Based Break Detection in Post-Tensioning Tendons
    Mahmoudkhani, Sadegh
    Algohi, Basheer
    Zhao, Junhui
    Ling, Henry
    Mufti, Aftab
    Thomson, Douglas
    [J]. 2019 IEEE SENSORS, 2019,
  • [49] Improved estimation of the reverse-cyclic behavior of fully-grouted masonry shear walls with unbonded post-tensioning
    Kalliontzis, D.
    Schultz, A. E.
    [J]. ENGINEERING STRUCTURES, 2017, 145 : 83 - 96
  • [50] Design criterion for the self-centering capacity of precast segmental UHPC bridge columns with unbonded post-tensioning tendons
    Wang, Zhen
    Wang, Jingquan
    Zhao, Guotang
    Zhang, Jian
    [J]. ENGINEERING STRUCTURES, 2019, 200