Comparative Analysis of Mathematical Models for Blood Flow in Tapered Constricted Arteries

被引:11
|
作者
Sankar, D. S. [1 ]
Yatim, Yazariah [2 ]
机构
[1] VIT Univ, Sch Adv Sci, Div Math, Madras 600127, Tamil Nadu, India
[2] Univ Sains Malaysia, Sch Math Sci, George Town 11800, Malaysia
关键词
UNSTEADY PULSATILE FLOW; NON-NEWTONIAN FLUID; BODY ACCELERATION; STENOSED ARTERIES; CASSON FLUID; RESISTANCE; VESSELS; LAYER;
D O I
10.1155/2012/235960
中图分类号
O29 [应用数学];
学科分类号
070104 ;
摘要
Pulsatile flow of blood in narrow tapered arteries with mild overlapping stenosis in the presence of periodic body acceleration is analyzed mathematically, treating it as two-fluid model with the suspension of all the erythrocytes in the core region as non-Newtonian fluid with yield stress and the plasma in the peripheral layer region as Newtonian. The non-Newtonian fluid with yield stress in the core region is assumed as (i) Herschel-Bulkley fluid and (ii) Casson fluid. The expressions for the shear stress, velocity, flow rate, wall shear stress, plug core radius, and longitudinal impedance to flow obtained by Sankar (2010) for two-fluid Herschel-Bulkley model and Sankar and Lee (2011) for two-fluid Casson model are used to compute the data for comparing these fluid models. It is observed that the plug core radius, wall shear stress, and longitudinal impedance to flow are lower for the two-fluid H-B model compared to the corresponding flow quantities of the two-fluid Casson model. It is noted that the plug core radius and longitudinal impedance to flow increases with the increase of the maximum depth of the stenosis. The mean velocity and mean flow rate of two-fluid H-B model are higher than those of the two-fluid Casson model.
引用
收藏
页数:34
相关论文
共 50 条
  • [21] Mathematical analysis of hybrid mediated blood flow in stenosis narrow arteries
    Hussain, Azad
    Sarwar, Lubna
    Rehman, Aysha
    Al Mdallal, Qasem
    Almaliki, Abdulrazak H.
    El-Shafay, A. S.
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [22] Mathematical analysis of hybrid mediated blood flow in stenosis narrow arteries
    Azad Hussain
    Lubna Sarwar
    Aysha Rehman
    Qasem Al Mdallal
    Abdulrazak H. Almaliki
    A. S. El-Shafay
    Scientific Reports, 12
  • [23] A Two-Layer Mathematical Model of Blood Flow in Porous Constricted Blood Vessels
    Sharma, Bhupesh Dutt
    Yadav, Pramod Kumar
    TRANSPORT IN POROUS MEDIA, 2017, 120 (01) : 239 - 254
  • [24] A Two-Layer Mathematical Model of Blood Flow in Porous Constricted Blood Vessels
    Bhupesh Dutt Sharma
    Pramod Kumar Yadav
    Transport in Porous Media, 2017, 120 : 239 - 254
  • [25] Nonlinear Fluid Models for Biofluid Flow in Constricted Blood Vessels under Body Accelerations: A Comparative Study
    Sankar, D. S.
    Nagar, Atulya K.
    JOURNAL OF APPLIED MATHEMATICS, 2012,
  • [26] Mathematical Analysis of Blood Flow in Porous Tubes: A Comparative Study
    Sankar, D. S.
    Nagar, Atulya K.
    ADVANCES IN MECHANICAL ENGINEERING, 2013,
  • [28] A nonlinear mathematical model of blood flow in a constricted artery experiencing body acceleration
    Chakravarty, S
    Sannigrahi, AK
    MATHEMATICAL AND COMPUTER MODELLING, 1999, 29 (08) : 9 - 25
  • [29] sAn unsteady analysis of non-Newtonian blood flow through tapered arteries with a stenosis
    Mandal, PK
    INTERNATIONAL JOURNAL OF NON-LINEAR MECHANICS, 2005, 40 (01) : 151 - 164
  • [30] Theoretical study on the constricted flow phenomena in arteries
    S. Sen
    S. Chakravarty
    Korea-Australia Rheology Journal, 2012, 24 : 287 - 295