Compact Two Degrees-of-Freedom External Fixator System for Correction of Persistent Clubfoot Deformity

被引:3
|
作者
Wu, Ying Ying [1 ]
Plakseychuk, Anton [2 ]
Shimada, Kenji [3 ]
机构
[1] Carnegie Mellon Univ, Dept Biomed Engn, 5000 Forbes Ave, Pittsburgh, PA 15213 USA
[2] Univ Pittsburgh, Med Ctr, Magee Womens Hosp, Ctr Bone & Joint, 300 Halket St, Pittsburgh, PA 15213 USA
[3] Carnegie Mellon Univ, Dept Mech Engn, 5000 Forbes Ave, Pittsburgh, PA 15213 USA
关键词
PONSETI METHOD; FOOT; MANAGEMENT; RELAPSE;
D O I
10.1115/1.4043109
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Bone deformities are often complex three-dimensional (3D) deformities, and correcting them is difficult. To correct persistent clubfoot deformity in adolescents or adults, an external fixator is sometimes used to encourage tissue growth and preserve healthy tissues. However, it is difficult to set up, resulting in long surgeries and steep learning curves for surgeons. It is also bulky and obstructs patient mobility. In this paper, we introduce a new approach of defining clubfoot deformity correction as a six degrees-of-freedom (6DOF) correction, and then reducing it to just two degrees-of-freedom (2DOF) using the axis-angle representation. Therefore, only two physical trajectory joints are needed, which in turn enables a more compact fixator design. A computer planner was developed to minimize the bulk of the external fixator, and to optimize the distraction schedule to avoid overstretching the soft tissues. This reduces the learning curve for surgeons and shortens surgery time. To validate the system, a patient-specific clubfoot simulator was developed, and four experiments were performed on the clubfoot simulator. The accuracy of midfoot correction was 11mm and 3.5 deg without loading, and 41mm and 11.7 deg with loading. While the external fixator has to be more rigid to overcome resistance against correction, the surgical system itself was able to achieve accurate correction in less than 2 h. This is an improvement from the current method, which takes 2.5-4.5 h.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] An experimental two degrees-of-freedom actuated external fixator for in vivo investigation of fracture healing
    Bishop, NE
    Schneider, E
    Ito, K
    MEDICAL ENGINEERING & PHYSICS, 2003, 25 (04) : 335 - 340
  • [2] Deformity correction with external fixator in pseudoachondroplasia
    Li, Qi-Wei
    Song, Hae-Ryong
    Mahajan, Ravindra H.
    Suh, Seung-Woo
    Lee, Seok-Hyun
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (454) : 174 - 179
  • [3] Evaluation of the stability of a two degrees-of-freedom dynamical system
    Amer, T. S.
    Ismail, A. I.
    Amer, W. S.
    JOURNAL OF LOW FREQUENCY NOISE VIBRATION AND ACTIVE CONTROL, 2023, 42 (04) : 1578 - 1595
  • [4] Correction of neglected clubfoot using the Ilizarov external fixator
    Ferreira, RC
    Costo, MT
    Frizzo, GG
    da Fonseca, FF
    FOOT & ANKLE INTERNATIONAL, 2006, 27 (04) : 266 - 273
  • [5] Complex rigid foot deformity correction with hexapod external fixator system
    Sancar Bakircioglu
    Murat Danisman
    Ozan Tuncay
    Ulas Can Kolac
    Muhammed Abdulkadir Bulut
    Guney Yilmaz
    International Orthopaedics, 2023, 47 : 2773 - 2780
  • [6] Complex rigid foot deformity correction with hexapod external fixator system
    Bakircioglu, Sancar
    Danisman, Murat
    Tuncay, Ozan
    Kolac, Ulas Can
    Bulut, Muhammed Abdulkadir
    Yilmaz, Guney
    INTERNATIONAL ORTHOPAEDICS, 2023, 47 (11) : 2773 - 2780
  • [7] Intelligent external fixator for fracture treatment and deformity correction
    Seide, K.
    Gerlach, U-J
    Wendlandt, R.
    Weinrich, N.
    Mueller, J.
    Juergens, C.
    TRAUMA UND BERUFSKRANKHEIT, 2007, 9 (02) : 109 - 116
  • [8] Deformity correction and lengthening of lower legs with an external fixator
    Matsubara, Hidenori
    Tsuchiya, Hiroyuki
    Sakurakichi, Keisuke
    Watanabe, Koji
    Tomita, Katsuro
    INTERNATIONAL ORTHOPAEDICS, 2006, 30 (06) : 550 - 554
  • [9] Deformity correction and lengthening of lower legs with an external fixator
    Hidenori Matsubara
    Hiroyuki Tsuchiya
    Keisuke Sakurakichi
    Koji Watanabe
    Katsuro Tomita
    International Orthopaedics, 2006, 30 : 550 - 554
  • [10] Evaluation of the external fixator TrueLok Hexapod System for tibial deformity correction in children
    Pesenti, S.
    Iobst, C. A.
    Launay, F.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2017, 103 (05) : 761 - 764