Experimental study on seismic behavior of the damage-control steel plate fuses for beam-to-column connection

被引:9
|
作者
Lin, Xuchuan [1 ,2 ]
Li, Hang [1 ]
He, Liusheng [3 ]
Zhang, Lingxin [1 ,2 ]
机构
[1] China Earthquake Adm, Inst Engn Mech, Key Lab Earthquake Engn & Engn Vibrat, Harbin 150080, Peoples R China
[2] Minist Emergency Management, Key Lab Earthquake Disaster Mitigat, Harbin 150080, Peoples R China
[3] Tongji Univ, Coll Civil Engn, Dept Disaster Mitigat Struct, Shanghai 200092, Peoples R China
基金
中国国家自然科学基金;
关键词
Damage-control fuse; Loading protocol; Hysteretic response; Compressive strength; Out-of-plane deformation;
D O I
10.1016/j.engstruct.2022.114862
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Adoption of replaceable damage-control steel plate fuses at the intended location of beam-to-column connection is a potential solution for achieving seismic resilient steel structures. Different from the previous design concept, in this study, buckling of the plate fuse is made full use of to avoid excessive strength increase and also works as a visible damage indicator. Seismic behavior of the proposed damage-control fuses for the beam-to-column connection is studied in detail. Six fuse specimens are designed and experimentally investigated for various fuse dimensions and different loading protocols. Buckling under compression and eventual fracture under tension is the typical failure pattern. The obtained hysteretic curve of the fuse exhibits the feature of asymmetry, with tensile strength larger than compressive strength and the difference becoming larger with the increase of loading amplitude. Different cyclic loading protocols have a greater influence on the ductility than the maximum strength. The compressive strength of the fuse is theoretically estimated, which gives fairly good agreement with the test results. All the fuse specimens can reach the loading amplitude of 5% effective length without fracture. The maximum strength of the fuse degrades with the progress of out-of-plane deformation. The out-of-plane deformation of the fuses could be treated as a visible indicator for determining whether or not to replace the damaged fuse.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Seismic Performance of Steel Beam-To-Column Joint with Replaceable Buckling-Restrained Energy Dissipation Fuses
    Chen, Peng
    Hu, Fangxin
    Pan, Jianrong
    Wang, Zhan
    PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON BEHAVIOUR OF STEEL STRUCTURES IN SEISMIC AREAS, STESSA 2022, 2022, 262 : 820 - 827
  • [32] Experimental study on beam-to-column clip angle bolted connection
    Natesan, Vijayakumar
    Madhavan, Mahendrakumar
    THIN-WALLED STRUCTURES, 2019, 141 : 540 - 553
  • [33] Numerical investigation on seismic resilient steel beam-to-column connections with replaceable buckling-restrained fuses
    Chen, Peng
    Pan, Jianrong
    Hu, Fangxin
    Wang, Zhan
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2022, 199
  • [34] Study on highly elastic seismic structural system based on very-high strength steel and damage-control fuses
    Lin, Xuchuan
    Hu, Yangyang
    Okazaki, Taichiro
    ce/papers, 2017, 1 (2-3) : 3315 - 3320
  • [35] Determination of Hysteretic Behavior of Steel End-Plate Beam-to-Column Connection with Mechanical and Neural Network Modeling
    Gholamreza Abdollahzadeh
    Seyed Mojtaba Hashemi
    Hamidreza Tavakoli
    Hosein Rahami
    Arabian Journal for Science and Engineering, 2014, 39 : 7661 - 7671
  • [36] Determination of Hysteretic Behavior of Steel End-Plate Beam-to-Column Connection with Mechanical and Neural Network Modeling
    Abdollahzadeh, Gholamreza
    Hashemi, Seyed Mojtaba
    Tavakoli, Hamidreza
    Rahami, Hosein
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2014, 39 (11) : 7661 - 7671
  • [37] Experimental study on the structural performance of non-intersection type steel beam-to-column connection
    Yamada S.
    Yoshie K.
    Kouno T.
    Kojima D.
    Journal of Structural and Construction Engineering, 2010, 75 (656): : 1901 - 1908
  • [38] INFLUENCE OF THE CYCLIC BEHAVIOUR OF BEAM-TO-COLUMN CONNECTION ON THE SEISMIC RESPONSE OF REGULAR STEEL FRAMES
    Montuori, Rosario
    Nastri, Elide
    Piluso, Vincenzo
    Troisi, Marina
    INGEGNERIA SISMICA, 2016, 33 (1-2): : 91 - 106
  • [39] Experimental evaluation of the post-fire behavior of steel T-component in the beam-to-column connection
    Sagiroglu, Merve
    FIRE SAFETY JOURNAL, 2018, 96 : 153 - 164
  • [40] Experimental evaluation of the post-fire behavior of steel T-component in the beam-to-column connection
    Sagiroglu M.
    2018, Elsevier Ltd (96) : 153 - 164