10-year results of ReCap hip resurfacing arthroplasty: a non-designer case series

被引:4
|
作者
Kiran, Manish [1 ]
Santhapuri, Sunil [1 ]
Moeen, Sara [1 ]
Merchant, Irfan [1 ]
Arvinte, Dan [1 ]
Sood, Manoj [1 ]
机构
[1] Bedford Hosp, Kempston Rd, Bedford MK4 29DJ, England
关键词
Arthroplasty; ReCap Magnum hip resurfacing; young adult; COMPONENT; SYSTEM;
D O I
10.1177/1120700019832260
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: We present the 10-year results of the ReCap Magnum HRA system in a consecutive single surgeon's series from a non-designer centre. Patients and methods: Hip resurfacing arthroplasty (HRA) was performed in active males under 65 years and in pre-menopausal females with adequate bone density proven by a DEXA scan. Clinical follow-up; annual Oxford hip scoring, UCLA scoring and whole blood metal ion level measurement. Kaplan-Meier method was used to determine survivorship with revision as the end point. Radiographs were analysed for; acetabular inclination, notching, neck thinning and change in implant position. 72 HRAs were performed in 66 patients with a mean age of 45.7 years. The mean follow-up was 10.63 +/- 0.54 years (range 10-11.75 years). Results: The survivorship of the cohort at minimum 10 years was 97.22% (95% confidence interval 94.14-99.01). There was a significant improvement in the Oxford Hip Score from 15.77 +/- 4.33 to 45.67 +/- 4.43 (p < 0.001) and the UCLA score from 3.14 +/- 0.74 to 7.07 +/- 1.16 (p < 0.001). Mean whole blood cobalt and chromium levels were 28.83 +/- 8.42 nmol/l and 39.93 +/- 9.64 nmol/l respectively. There were 2 revisions, due to avascular necrosis and implant failure. In our series the implant has performed well with <1% failure per year. We did not note any difference between the genders, since all the females in our series had been screened for osteopenia using a DEXA scan. All our patients returned to an active lifestyle which was maintained at final follow-up. Conclusion: Strict selection criteria and a well-designed implant result in good long-term functional and radiological results with hip resurfacing.
引用
收藏
页码:393 / 397
页数:5
相关论文
共 50 条
  • [31] Omnifit cementless total hip arthroplasty - A 10-year average followup
    Hellman, EJ
    Capello, WN
    Feinberg, JR
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1999, (364) : 164 - 174
  • [32] Prospective clinical and radiographic 10-year results of Fitmore short-stem total hip arthroplasty
    Schader, Jana Felicitas
    Thalmann, Caroline
    Maier, Katharina Sophia
    Schiener, Tom
    Stoffel, Karl
    Frigg, Arno
    [J]. SWISS MEDICAL WEEKLY, 2023, 153 : 76S - 76S
  • [33] Pseudotumours associated with metal-on-metal hip resurfacing: 10-year Newcastle experience
    Malviya, Ajay
    Holland, James P.
    [J]. ACTA ORTHOPAEDICA BELGICA, 2009, 75 (04): : 477 - 483
  • [34] Metal-on-Metal Hip Resurfacing and Total Hip Arthroplasty in the Same Patient: A Case Series Comparison
    Morrison, Todd A.
    Macaulay, William
    Geller, Jeffrey A.
    [J]. OPERATIVE TECHNIQUES IN ORTHOPAEDICS, 2009, 19 (03) : 182 - 187
  • [35] Clinical results and 10-year survivorship of the Synthes Epoca resurfacing total shoulder arthroplasty (vol 14, pg 615, 2022)
    Karssiens, James T.
    Zhou, R.
    Gill, Ritchie J.
    [J]. SHOULDER & ELBOW, 2022, 14 (06) : 692 - 692
  • [36] Minimum 10-year results of a tapered cementless hip replacement
    Sakalkale, DP
    Eng, K
    Hozack, WJ
    Rothman, RH
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1999, (362) : 138 - 144
  • [37] A Case Series of Total Hip Arthroplasty Using Cementless Hip Stem Customized for Patients of a Specific Race: 10-to 15-Year Results
    Tsukada, Sachiyuki
    Wakui, Motohiro
    [J]. JOURNAL OF ARTHROPLASTY, 2016, 31 (01): : 190 - 193
  • [38] Prospective evaluation of clinical and radiographic 10-year results of Fitmore short-stem total hip arthroplasty
    Jana F. Schader
    Caroline Thalmann
    Katharina S. Maier
    Tom Schiener
    Karl Stoffel
    Arno Frigg
    [J]. Journal of Orthopaedic Surgery and Research, 18
  • [39] Revision total hip arthroplasty with the use of structural acetabular allograft and reconstruction ring - A case series with a 10-year average follow-up
    Saleh, KJ
    Jaroszynski, G
    Woodgate, I
    Saleh, L
    Gross, AE
    [J]. JOURNAL OF ARTHROPLASTY, 2000, 15 (08): : 951 - 958
  • [40] Prospective evaluation of clinical and radiographic 10-year results of Fitmore short-stem total hip arthroplasty
    Schader, Jana F.
    Thalmann, Caroline
    Maier, Katharina S.
    Schiener, Tom
    Stoffel, Karl
    Frigg, Arno
    [J]. JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)