New modification of xenon gamma-ray detector with high energy resolution

被引:19
|
作者
Novikov, Alexander S. [1 ]
Ulin, Sergey E. [1 ]
Dmitrenko, Valery V. [1 ]
Uteshev, Ziyaetdin M. [1 ]
Vlasik, Konstantin F. [1 ]
Grachev, Victor M. [1 ]
Efremenko, Yuri V. [2 ]
Chernysheva, Irina V. [1 ]
Shustov, Alexander E. [1 ]
机构
[1] Natl Res Nucl Univ MEPhI, Moscow 115409, Russia
[2] Univ Tennessee, Knoxville, TN 37996 USA
关键词
gamma rays; sensors; detectors; PRESSURE; SPECTROSCOPY;
D O I
10.1117/1.OE.53.2.021108
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Performance of a new modification of xenon gamma-ray detector (XGD) is presented. This detector differs from the previous ones by virtue of improved energy resolution (1.7 +/- 0.1)% at 662 keV and the ability to function in the presence of external acoustic noise (up to 100 dB) with virtually no degradation of spectrometric characteristics. These results have been achieved by developing a digital method of processing every electric signal coming from the XGD. For this method, digital electronics based on field-programmable gate array has also been developed. (C) 2014 Society of Photo-Optical Instrumentation Engineers (SPIE)
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Temperature control design for a high-resolution gamma-ray tomography detector
    Bieberle, Andre
    Schleicher, Eckhard
    Hampel, Uwe
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2010, 81 (01):
  • [22] New intensities for high energy gamma-ray standards
    Molnar, GL
    Revay, Z
    Belgya, T
    CAPTURE GAMMA-RAY SPECTROSCOPY AND RELATED TOPICS, 2003, : 522 - 530
  • [23] Vibrostability of high pressure xenon gamma-ray detectors
    Dmitrenko, V.V.
    Chernysheva, I.V.
    Gratchev, V.M.
    Kondakova, O.N.
    Krivova, K.V.
    Ulin, S.E.
    Uteshev, Z.M.
    Vlasik, K.F.
    IEEE Transactions on Nuclear Science, 2000, 47 (3 II) : 939 - 943
  • [24] Gamma-ray bursts and very high energy gamma-ray astronomy
    Hurley, K
    SPACE SCIENCE REVIEWS, 1996, 75 (1-2) : 43 - 52
  • [25] A new CdZnTe detector system for low-energy gamma-ray measurement
    Johansen, GA
    Abro, E
    SENSORS AND ACTUATORS A-PHYSICAL, 1996, 54 (1-3) : 493 - 498
  • [26] Large area gamma-ray imaging detector based on high resolution CdTe diode
    Mitani, T
    Nakamura, H
    Uno, S
    Takahashi, T
    Nakazawa, K
    Watanabe, S
    Tajima, H
    Nomachi, M
    Fukazawa, Y
    Kubo, S
    Kuroda, Y
    Onishi, M
    Ohno, R
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 274 - 277
  • [27] A GAMMA-RAY DETECTOR WITH GOOD TIME RESOLUTION AND HIGH SIGNAL-TO-NOISE RATIO
    METGE, J
    RUFFER, R
    GERDAU, E
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 292 (01): : 187 - 190
  • [28] Development of a compact high resolution gamma-ray detector for E-CT applications
    Zhu jie
    Ma Hongguang
    Ma Wenyan
    Zeng Hui
    Wang Zhaomin
    Xu Zizhong
    NUCLEAR SCIENCE AND TECHNIQUES, 2007, 18 (05) : 302 - 306
  • [29] Development of a compact high resolution gamma-ray detector for E-CT applications
    ZHU Jie1 MA Hongguang1 MA Wenyan1 ZENG Hui2 WANG Zhaomin2 XU Zizhong2 (1 Department of Nuclear Engineering
    2 Department of Modern Physics
    NuclearScienceandTechniques, 2007, (05) : 302 - 306
  • [30] USE OF CRYSTAL DIFFRACTION WITH GE DIODE DETECTOR FOR HIGH RESOLUTION GAMMA-RAY SPECTROSCOPY
    SMITHER, RK
    NAMENSON, AI
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1967, 38 (01): : 52 - &