Long-term outcome of pulmonary vein isolation in patients with paroxysmal atrial fibrillation and Brugada syndrome

被引:9
|
作者
Mugnai, Giacomo [1 ]
Hunuk, Burak [1 ]
Stroker, Erwin [1 ]
Ruggiero, Diego [1 ]
Coutino-Moreno, Hugo Enrique [1 ]
Takarada, Ken [1 ]
De Regibus, Valentina [1 ]
Choudhury, Rajin [1 ]
de Torres, Juan Pablo Abugattas [1 ]
Moran, Darragh [1 ]
Iacopino, Saverio [2 ]
Filannino, Pasquale [2 ]
Conte, Giulio [1 ]
Sieira, Juan [1 ]
Poelaert, Jan [3 ]
Beckers, Stefan [3 ]
Brugada, Pedro [1 ]
de Asmundis, Carlo [1 ]
Chierchia, Gian-Battista [1 ]
机构
[1] UZ Brussel, Heart Rhythm Management Ctr, VUB Laarbeklaan 101, B-1090 Brussels, Belgium
[2] Maria Cecilia Hosp, Electrophysiol Unit, Via Corriera 1, I-48033 Cotignola, RA, Italy
[3] UZ Brussel, Dept Anaesthesiol, VUB Laarbeklaan 101, B-1090 Brussels, Belgium
来源
EUROPACE | 2018年 / 20卷 / 03期
关键词
Atrial fibrillation; Brugada syndrome; Pulmonary vein isolation; Cryoballoon; Radiofrequency; Inappropriate shock; IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR; HEART-RHYTHM-ASSOCIATION; FOLLOW-UP; CRYOBALLOON ABLATION; CATHETER ABLATION; PREVALENCE; MANAGEMENT; EFFICACY; 1ST;
D O I
10.1093/europace/euw428
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The therapeutical management of atrial fibrillation (AF) in the setting of Brugada syndrome (BS) might be challenging as many antiarrhythmic drugs (AADs) with sodium channel blocking properties might lead to to the development of ventricular arrhythmias. This study sought to evaluate the clinical outcome in a consecutive series of patients with BS having undergone pulmonary vein (PV) isolation by means of radiofrequency (RF) or cryoballoon (CB) ablation and the efficacy of catheter ablation for preventing inappropriate interventions delivered by implantable cardioverter defibrillators (ICD) on a 3-year follow up. Twenty-three consecutive patients with BS (13 males; mean age was 47 +/- 18 years) having undergone PV isolation for drug-resistant paroxysmal AF were enrolled. Eleven patients (48%) had an ICD implanted of whom four had inappropriate shocks secondary to rapid AF. Over a mean follow-up period of 35.0 +/- 25.4 months (median 36 months) the freedom from AF recurrence after the index PV isolation procedure was 74% without AADs. Patients with inappropriate ICD interventions for AF did not present futher ICD shocks after AF ablation. No major complications occurred. Catheter ablation is a valid therapeutic choice for patients with BS and paroxysmal AF considering the high success rates, the limitations of the AADs and the safety of the procedure, and it should be taken into consideration especially in those patients presenting inappropriate ICD shocks due to rapid AF.
引用
收藏
页码:548 / 554
页数:7
相关论文
共 50 条
  • [31] Long-term outcome and preprocedural predictors of atrial tachyarrhythmia recurrence following pulmonary vein antrum isolation-based catheter ablation in patients with non-paroxysmal atrial fibrillation
    Ejima, Koichiro
    Arai, Kotaro
    Suzuki, Tsuyoshi
    Kato, Ken
    Yoshida, Kentaro
    Nuki, Toshiaki
    Suzuki, Futoshi
    Uematsu, Shoko
    Fukushima, Keiko
    Hoshi, Hiromi
    Manaka, Tetsuyuki
    Ashihara, Kyomi
    Shoda, Morio
    Hagiwara, Nobuhisa
    JOURNAL OF CARDIOLOGY, 2014, 64 (01) : 57 - 63
  • [32] Influence of pulmonary vein isolation on autonomic function in patients with paroxysmal atrial fibrillation
    De Greef, Y.
    Galloo, X.
    Schwagten, B.
    Wolf, M.
    De Cocker, J.
    Vermeulen, C.
    Korpela, S.
    Smekens, F.
    Verhaegen, L.
    Cleyman, I.
    ACTA CARDIOLOGICA, 2018, 73 (05) : 501 - 502
  • [33] Quality of life in patients with paroxysmal atrial fibrillation after pulmonary vein isolation
    Berkowitsch, A
    Neumann, T
    Kurzidim, K
    Siemon, G
    Sperzel, J
    Pitschner, HF
    EUROPEAN HEART JOURNAL, 2002, 23 : 524 - 524
  • [34] Efficacy of pulmonary vein isolation by cryoballon ablation in patients with paroxysmal atrial fibrillation
    Klein, Gunnar
    Oswald, Hanno
    Gardiwal, Ajmal
    Luesebrink, Ulrich
    Lissel, Christoph
    Yu, Hong
    Drexler, Helmut
    HEART RHYTHM, 2008, 5 (06) : 802 - 806
  • [35] Experience matters: long-term results of pulmonary vein isolation using a robotic navigation system for the treatment of paroxysmal atrial fibrillation
    Andreas Rillig
    Tina Lin
    Boris Schmidt
    Britta Feige
    Christian Heeger
    Jascha Wegner
    Erik Wissner
    Andreas Metzner
    Anita Arya
    Shibu Mathew
    Peter Wohlmuth
    Feifan Ouyang
    Karl-Heinz Kuck
    Roland Richard Tilz
    Clinical Research in Cardiology, 2016, 105 : 106 - 116
  • [36] Experience matters: long-term results of pulmonary vein isolation using a robotic navigation system for the treatment of paroxysmal atrial fibrillation
    Rillig, Andreas
    Lin, Tina
    Schmidt, Boris
    Feige, Britta
    Heeger, Christian
    Wegner, Jascha
    Wissner, Erik
    Metzner, Andreas
    Arya, Anita
    Mathew, Shibu
    Wohlmuth, Peter
    Ouyang, Feifan
    Kuck, Karl-Heinz
    Tilz, Roland Richard
    CLINICAL RESEARCH IN CARDIOLOGY, 2016, 105 (02) : 106 - 116
  • [37] Long-term results in antral isolation of pulmonary veins with cryoballoon technique in paroxysmal atrial fibrillation
    Vogt, J.
    Dorszewski, A.
    Heintze, J.
    Wetzel, U.
    Scholz, U.
    Muntean, B. G.
    Thanh, L. Luong
    Horstkotte, D.
    EUROPEAN HEART JOURNAL, 2008, 29 : 409 - 409
  • [38] Long-term Outcome and the Mechanisms of Pulmonary Antrum Radial-linear Ablation in Patients With Paroxysmal Atrial Fibrillation
    Zhao, Xue
    Hu, Jianqiang
    Huang, Yan
    Xu, Yawei
    Zhang, Yanzhou
    Gong, Hui
    Liu, Zhenguo
    CIRCULATION, 2015, 132
  • [39] Long-term Outcome and the Mechanisms of Pulmonary Antrum Radial-linear Ablation in Patients with Paroxysmal Atrial Fibrillation
    Zhao, Xue
    Liao, Dening
    Guo, Xingui
    Xu, Yawei
    Zhang, Yanzhou
    Gong, Hui
    Liu, Zhenguo
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (16) : C183 - C183
  • [40] Long-term outcome and the mechanisms of pulmonary antrum radial-linear ablation in patients with paroxysmal atrial fibrillation
    Zhao, X.
    Zhu, Y. X.
    Zhang, J. Y.
    Liao, D. N.
    Hu, J. Q.
    Lu, W. L.
    Huang, Y.
    Zhang, Y. Z.
    Gong, H.
    Liu, Z. G.
    EUROPEAN HEART JOURNAL, 2015, 36 : 736 - 736