Conceptual design of a cryogen-free μMRI device

被引:4
|
作者
Authelet, G. [1 ]
Poirier-Quinot, M. [2 ]
Ginefri, J-C [2 ]
Bonelli, A. [1 ]
Baudouy, B. [1 ]
机构
[1] Unversite Paris Saclay, CEA, Irfu, F-91191 Gif Sur Yvette, France
[2] Univ Paris Sclay, Univ Paris Sud, CNRS, IR4M,UMR8081, Orsay, France
来源
关键词
NATURAL CIRCULATION LOOP; HEAT-TRANSFER; SURFACE COIL;
D O I
10.1088/1757-899X/278/1/012122
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
To perform Micro Magnetic Resonance Imaging (mu MRI) analysis on small regions such as skins, articulations or small animals, the required spatial resolution implies to dramatically improve the sensitivity of the detection. One way to go is to use small radio frequency superconducting coil that allow, among others, increasing significantly the signal-to-noise ratio. The RF probe, constituted of an optimized YBaCuO film coil cooled below nitrogen temperature, must be located no further than few millimeters from the biological region to be imaged in a clinical MRI magnet. To fulfill the medical environment and constraints, a cryogen free cooling scheme has been developed to maintain the superconducting coil at the working temperature. The cryogenic design is based on a pulse tube cryocooler and solid thermal links inserted in a non-magnetic cryostat to avoid creating any electromagnetic perturbations to the MRI magnet and the measurements. We report here the conceptual design of the cryogenic system with the required thermal performances, the corresponding layout and architecture of the system as well as the main technical challenges met for the construction.
引用
收藏
页数:7
相关论文
共 50 条
  • [2] Cryogen-free NMR
    不详
    R&D MAGAZINE, 2004, 46 (06): : 17 - 17
  • [3] STRUCTURAL DESIGN AND ANALYSIS OF A CRYOGEN-FREE OPEN SUPERCONDUCTING MAGNET FOR INTERVENTIONAL MRI APPLICATIONS
    MINAS, C
    LASKARIS, ET
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 1995, 5 (02) : 173 - 176
  • [4] Gradient coil design with enhanced shielding constraint for a cryogen-free superconducting MRI system
    Wang, Yaohui
    Wang, Weimin
    Liu, Hui
    Chen, Shunzhong
    Liu, Feng
    Wang, Qiuliang
    MAGNETIC RESONANCE LETTERS, 2024, 4 (01)
  • [5] Design of the cryogen-free cryogenic system for the CUORE experiment
    Nucciotti, A.
    Schaeffer, D.
    Alessandria, F.
    Ardito, R.
    Barucci, M.
    Risegari, L.
    Ventura, G.
    Bucci, C.
    Frossati, G.
    Olcese, M.
    de Waard, A.
    JOURNAL OF LOW TEMPERATURE PHYSICS, 2008, 151 (3-4) : 662 - 668
  • [6] Design of the Cryogen-Free Cryogenic System for the CUORE Experiment
    A. Nucciotti
    D. Schaeffer
    F. Alessandria
    R. Ardito
    M. Barucci
    L. Risegari
    G. Ventura
    C. Bucci
    G. Frossati
    M. Olcese
    A. de Waard
    Journal of Low Temperature Physics, 2008, 151 : 662 - 668
  • [7] Design, Fabrication and Measurement of a 3 T Cryogen-Free Animal MRI Superconducting Magnet
    Wang, Yaohui
    Liu, Hui
    Chen, Shunzhong
    Wang, Weimin
    Liu, Feng
    Wang, Qiuliang
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2024, 34 (05) : 1 - 4
  • [8] Structural design and analysis of a cryogen-free open superconducting magnet for interventional MRI applications
    General Electric Corp Research &, Development, Schenectady, United States
    IEEE Trans Appl Supercond, 2 pt 1 (173-176):
  • [9] Gradient coil design with enhanced shielding constraint for a cryogen-free superconducting MRI system
    Yaohui Wang
    Weimin Wang
    Hui Liu
    Shunzhong Chen
    Feng Liu
    Qiuliang Wang
    磁共振快报(英文), 2024, 4 (01) : 6 - 14
  • [10] A cryogen-free 0.5 TESLA MRI magnet for head imaging
    van Oort, JM
    Laskaris, ET
    Thompson, PS
    Dorri, B
    Herd, KG
    ADVANCES IN CRYOGENIC ENGINEERING, VOL 43 PTS A AND B, 1998, 43 : 139 - 147