Reliability and concurrent validity of the Microsoft Xbox One Kinect for assessment of standing balance and postural control

被引:127
|
作者
Clark, Ross A. [1 ]
Pua, Yong-Hao [1 ,2 ]
Oliveira, Cristino C. [1 ]
Bower, Kelly J. [1 ]
Thilarajah, Shamala [1 ,2 ]
McGaw, Rebekah [1 ]
Hasanki, Ksaniel [1 ]
Mentiplay, Benjamin F. [1 ]
机构
[1] Australian Catholic Univ, Sch Exercise Sci, Melbourne, Vic, Australia
[2] Singapore Gen Hosp, Dept Physiotherapy, Singapore, Singapore
关键词
Kinect; Balance; Kinect V2; XBox One Kinect; Functional reach; MOVEMENT; PEOPLE;
D O I
10.1016/j.gaitpost.2015.03.005
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The Microsoft Kinect V2 for Windows (TM), also known as the Xbox One Kinect, includes new and potentially far improved depth and image sensors which may increase its accuracy for assessing postural control and balance. The aim of this study was to assess the concurrent validity and reliability of kinematic data recorded using a marker-based three dimensional motion analysis (3DMA) system and the Kinect V2 during a variety of static and dynamic balance assessments. Thirty healthy adults performed two sessions, separated by one week, consisting of static standing balance tests under different visual (eyes open vs. closed) and supportive (single limb vs. double limb) conditions, and dynamic balance tests consisting of forward and lateral reach and an assessment of limits of stability. Marker coordinate and joint angle data were concurrently recorded using the Kinect V2 skeletal tracking algorithm and the 3DMA system. Task-specific outcome measures from each system on Day 1 and 2 were compared. Concurrent validity of trunk angle data during the dynamic tasks and anterior-posterior range and path length in the static balance tasks was excellent (Pearson's r > 0.75). In contrast, concurrent validity for medial-lateral range and path length was poor to modest for all trials except single leg eyes closed balance. Within device test-retest reliability was variable; however, the results were generally comparable between devices. In conclusion, the Kinect V2 has the potential to be used as a reliable and valid tool for the assessment of some aspects of balance performance. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:210 / 213
页数:4
相关论文
共 50 条
  • [31] The validity of a portable clinical force plate in assessment of static postural control: concurrent validity study
    Samira Golriz
    Jeffrey J Hebert
    K Bo Foreman
    Bruce F Walker
    [J]. Chiropractic & Manual Therapies, 20 (1)
  • [32] The validity of a portable clinical force plate in assessment of static postural control: concurrent validity study
    Golriz, Samira
    Hebert, Jeffrey
    Foreman, K.
    Walker, Bruce
    [J]. CHIROPRACTIC & MANUAL THERAPIES, 2012, 20
  • [33] Validity and Reliability of the Kinect for Assessment of Standardized Transitional Movements and Balance Systematic Review and Translation into Practice
    Puh, Urska
    Hoehlein, Brittany
    Deutsch, Judith E.
    [J]. PHYSICAL MEDICINE AND REHABILITATION CLINICS OF NORTH AMERICA, 2019, 30 (02) : 399 - +
  • [34] Accuracy Assessment of Kinect for Xbox One in Point-Based Tracking Applications
    Goral, Adrian
    Skalski, Andrzej
    [J]. EIGHTH INTERNATIONAL CONFERENCE ON MACHINE VISION (ICMV 2015), 2015, 9875
  • [35] Validity and Reliability of the Nintendo Wii in Measuring Standing Balance
    Field-Eaton, Sean D.
    Orloff, Heidi A.
    Nakamura, Bryson H.
    Olesh, Erienne V.
    [J]. JOURNAL OF GENERAL INTERNAL MEDICINE, 2012, 27 : 529 - 529
  • [36] Validity and Reliability of the Nintendo Wii in Measuring Standing Balance
    Field-Eaton, Sean D.
    Orloff, Heidi A.
    Nakamura, Bryson H.
    Olesh, Erienne V.
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2011, 43 (05): : 529 - 529
  • [37] Concurrent validity of the Microsoft Kinect for Windows v2 for measuring spatiotemporal gait parameters
    Dolatabadi, Elham
    Taati, Babak
    Mihailidis, Alex
    [J]. MEDICAL ENGINEERING & PHYSICS, 2016, 38 (09) : 952 - 958
  • [38] Validity of the Postural Control and Balance for Stroke test
    Pyoria, Outi
    Talvitie, Ulla
    Nyrkko, Hannu
    Kautiainen, Hannu
    Pohjolainen, Timo
    [J]. PHYSIOTHERAPY RESEARCH INTERNATIONAL, 2007, 12 (03) : 162 - 174
  • [39] Postural control analysis in multiple sclerosis with perceptive computing based on Microsoft's Kinect
    Behrens, J. R.
    Gusho, E.
    Mertens, S.
    Otte, K.
    Mansow-Model, S.
    Paul, F.
    Brandt, A.
    [J]. MULTIPLE SCLEROSIS JOURNAL, 2014, 20 : 61 - 61
  • [40] Low-cost visual postural feedback with Wii Balance Board and Microsoft Kinect - a feasibility study
    Dutta, Arindam
    Banerjee, Alakananda
    Dutta, Anirban
    [J]. 2013 IEEE POINT-OF-CARE HEALTHCARE TECHNOLOGIES (PHT), 2013, : 291 - 294