The passive and active contractile properties of the neurogenic, underactive bladder

被引:18
|
作者
Young, John S. [1 ]
Johnston, Louise [2 ]
Soubrane, Camille [3 ]
McCloskey, Karen D. [2 ]
McMurray, Gordon [3 ]
Eccles, Rachel [3 ]
Fry, Christopher H. [1 ]
机构
[1] Univ Surrey, Inst Biosci & Med, Guildford GU2 7XH, Surrey, England
[2] Queens Univ Belfast, Ctr Canc Res & Cell Biol, Sch Med Dent & Biomed Sci, Belfast, Antrim, North Ireland
[3] Pfizer Global Res & Dev, Sandwich, Kent, England
关键词
bladder; compliance; detrusor contractility; detrusor underactivity; spinal cord injury; SMOOTH-MUSCLE-CELLS; SPINAL-CORD-INJURY; DETRUSOR CONTRACTILITY; URINARY-BLADDER; COLLAGEN EXPRESSION; III COLLAGEN; OBSTRUCTION; RAT; HYPERACTIVITY; INCONTINENCE;
D O I
10.1111/j.1464-410X.2012.11300.x
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
What's known on the subject? and What does the study add? Detrusor underactivity is highly prevalent, particularly in the elderly. It is assumed to result from detrusor failure, although detrusor contractility is often derived from urodynamics studies. Given that detrusor pressure and force are not proportional and urodynamics cannot identify the basis of the pathology, we produced a neurogenic animal model with a highly-compliant bladder and studied detrusor muscle properties, aiming to increase our understanding of the underlying pathology. Highly compliant bladders were characterized by reduced passive wall stiffness and stretched detrusor muscle strips exhibited an enhanced rate of relaxation. These detrusor strips displayed spontaneous contractions that were of greater amplitude (expressed as a ratio of bladder wall stiffness) than those of strips from sham-operated animals; spontaneous contractions increased in amplitude when stimulated by an agonist. These data imply that compliance is not the result of a reduction of detrusor contractility; we hypothesize that altered matrix properties reduce the magnitude with which force can be generated to void the bladder. Objective To characterize passive and active changes in detrusor activity in a highly compliant bladder. Materials and Methods Bladders from adult female SpragueDawley rats were used 5 weeks after lower thoracic (T8) spinal cord transection or a sham-operation. Passive wall properties were assessed by pressurevolume relationships from whole bladders and the tensile response of bladder strips after a rapid (<0.5s) stretch. Active properties were assessed from the frequency and amplitude of spontaneous contractions of bladder strips, and their response to the inotropic TRPV4 agonist GSK1016790A. Results Passive bladder wall stiffness of SCT bladders was significantly reduced compared to that of the sham-operated control group (N = 6 and 8, respectively) and SCT bladder strips relaxed more quickly than those from sham-operated rats. The frequency of spontaneous contractions was reduced in SCT rats, and their amplitude, expressed as a ratio of bladder wall stiffness, was greater than in sham-operated rats. GSK1016790A (0.1M) significantly increased amplitude in strips from both sham-operated and SCT groups. Conclusions There is no evidence of contractile failure in a highly-compliant bladder. The observations of reduced passive bladder wall stiffness and an enhanced rate of stress relaxation lead to the conclusion that increased compliance is marked by altered matrix properties that dissipate muscle force, thereby generating low pressures. Contractile agonists may be effective for improving bladder function in detrusor underactivity.
引用
收藏
页码:355 / 361
页数:7
相关论文
共 50 条
  • [21] The overactive bladder progression to underactive bladder hypothesis
    Chancellor, Michael B.
    INTERNATIONAL UROLOGY AND NEPHROLOGY, 2014, 46 : S23 - S27
  • [22] Molecular Characteristics of Underactive Bladder
    Jiang, Yuan-Hong
    Kuo, Hann-Chorng
    CURRENT BLADDER DYSFUNCTION REPORTS, 2019, 14 (02) : 47 - 57
  • [23] Underactive Bladder and Bladder Outlet Procedures in Women
    Katherine K. Shapiro
    Pradeep Tyagi
    Christopher J. Chermansky
    Current Bladder Dysfunction Reports, 2020, 15 : 21 - 24
  • [24] Incontinence in Patients With Underactive Bladder
    Andersson, Karl-Erik
    INTERNATIONAL NEUROUROLOGY JOURNAL, 2020, 24 (03) : 293 - 294
  • [25] Underactive bladder - an underestimated entity
    Dan, Spinu Arsenie
    Bratu, Ovidiu Gabriel
    Marcu, Dragos Radu
    Stanciu, Adina Elena
    Gherghiceanu, Florentina
    Ionita-Radu, Florentina
    Bungau, Simona
    Stanescu, Ana Maria Alexandra
    Mischianu, Dan
    JOURNAL OF MIND AND MEDICAL SCIENCES, 2020, 7 (01): : 23 - 28
  • [26] Ultrastructural changes in the underactive bladder
    Ho, Han-Chen
    Hsu, Yung-Hsiang
    Jhang, Jia-Fong
    Jiang, Yuan-Hong
    Kuo, Hann-Chorng
    TZU CHI MEDICAL JOURNAL, 2021, 33 (04): : 345 - 349
  • [27] The overactive bladder progression to underactive bladder hypothesis
    Michael B. Chancellor
    International Urology and Nephrology, 2014, 46 : 23 - 27
  • [28] Pharmacological treatment of underactive bladder
    de Seze, M.
    Grise, P.
    de Seze, M. P.
    Roche, J. -B.
    Shao, E.
    Joseph, P. -A.
    PELVI-PERINEOLOGIE, 2007, 2 (02): : 184 - 192
  • [29] Underactive pharmaceutical bladder activity
    Wyllie, Mike G.
    BJU INTERNATIONAL, 2007, 100 (04) : 945 - 946
  • [30] Underactive Bladder and Bladder Outlet Procedures in Women
    Shapiro, Katherine K.
    Tyagi, Pradeep
    Chermansky, Christopher J.
    CURRENT BLADDER DYSFUNCTION REPORTS, 2020, 15 (01) : 21 - 24