Advantage of Pulsatility in Left Ventricular Reverse Remodeling and Aortic Insufficiency Prevention During Left Ventricular Assist Device Treatment

被引:25
|
作者
Imamura, Teruhiko [1 ]
Kinugawa, Koichiro [1 ]
Nitta, Daisuke [2 ]
Hatano, Masaru [2 ]
Kinoshita, Osamu [3 ]
Nawata, Kan [3 ]
Ono, Minoru [3 ]
机构
[1] Univ Tokyo, Grad Sch Med, Dept Therapeut Strategy Heart Failure, Tokyo 1138655, Japan
[2] Univ Tokyo, Grad Sch Med, Dept Cardiovasc Med, Tokyo 1138655, Japan
[3] Univ Tokyo, Grad Sch Med, Dept Cardiac Surg, Tokyo 1138655, Japan
关键词
Heart failure; INTERMACS; Pulsatile flow; Ventricular assist devices; MECHANICAL CIRCULATORY SUPPORT; CONTINUOUS-FLOW; HEART-FAILURE; TIME-COURSE; RECOVERY; IMPLANTATION; HEMODYNAMICS; RESPONSES; PRESSURE; SYSTEM;
D O I
10.1253/circj.CJ-15-0419
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: A continuous flow (CF) left ventricular assist device (LVAD) has various advantages over a pulsatile flow (PF) LVAD, but the extent of preventing aortic insufficiency (AI) by each type of LVAD remains controversial. Methods and Results: Of 86 patients with non-ischemic cardiomyopathy who underwent LVAD implantation between 2006 and 2015, 20 propensity score-matched patients with PF LVADs and 20 with CF LVADs were enrolled in this study. There were no significant differences in the baseline variables of both groups. During the 6-month LVAD treatment, the LV ejection fraction of the PF group was significantly higher than that of the CF group; the PF group also had a wider pulse pressure and less enlargement of the aortic root (P< 0.05 for all). Patients in the PF group experienced more frequent opening of the native aortic valve and less AI than those in the CF group (P< 0.05 for both). The PF LVAD was explanted in 5 patients (25%), and a CF LVAD was explanted in 1 patient (5%). Conclusions: Compared with CF LVADs, PF LVADs seem to have an advantage in improving LV reverse remodeling and preventing AI. It may be best to incorporate pulsatility into current CF LVADs while retaining their existing benefits.
引用
收藏
页码:1994 / 1999
页数:6
相关论文
共 50 条
  • [41] Transcatheter Aortic Valve Implantation In Left Ventricular Assist Device Patients With Severe Aortic Insufficiency
    Behbahani-Nejad, Omid
    Mahdavi, Asma
    Nayak, Aditi
    Babaliaros, Vasilis
    Leshnower, Bradley G.
    Greenbaum, Adam
    Byku, Isida
    Perdoncin, Emily
    Jokhadar, Maan
    [J]. JOURNAL OF CARDIAC FAILURE, 2023, 29 (04) : 585 - 585
  • [42] Outcomes Of Transcatheter Aortic Valve Implantation For Aortic Insufficiency In Left Ventricular Assist Device Patients
    Dimeglio, Matthew
    Ullah, Waqas
    Hajduczok, Alexander
    Vishnevsky, Alec
    Rajapreyar, Indranee
    Brailovsky, Yevgeniy
    Alvarez, Rene
    [J]. JOURNAL OF CARDIAC FAILURE, 2023, 29 (04) : 625 - 625
  • [43] LEFT VENTRICULAR ASSIST DEVICE PUMP SPEED, AORTIC VALVE CLOSURE AND INCIDENCE OF AORTIC INSUFFICIENCY
    Mukunda, Neha
    Birati, Edo Y.
    Johnson, Bryce V.
    Wald, Joyce
    Atluri, Pavan
    Goldberg, Lee
    Urgo, Kimberly
    Rao, Sriram D.
    Genuardi, Michael
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2021, 77 (18) : 749 - 749
  • [44] Aortic valve pathophysiology during left ventricular assist device support
    John, Ranjit
    Mantz, Katie
    Eckman, Peter
    Rose, Alan
    May-Newman, Karen
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2010, 29 (12): : 1321 - 1329
  • [45] Hemodynamic controller for left ventricular assist device based on pulsatility ratio
    Choi, Seongjin
    Boston, J. Robert
    Antaki, James F.
    [J]. ARTIFICIAL ORGANS, 2007, 31 (02) : 114 - 125
  • [46] Preoperative Prediction of Aortic Insufficiency During Ventricular Assist Device Treatment
    Imamura, Teruhiko
    Kinugawa, Koichiro
    [J]. INTERNATIONAL HEART JOURNAL, 2016, 57 (01) : 3 - 10
  • [47] Impact of left ventricular assist device (LVAD) support on the cardiac reverse remodeling process
    Klotza, Stefan
    Danser, A. H. Jan
    Burkhoff, Daniel
    [J]. PROGRESS IN BIOPHYSICS & MOLECULAR BIOLOGY, 2008, 97 (2-3): : 479 - 496
  • [48] Arterial pulsatility under phasic left ventricular assist device support
    Bozkurt, Selim
    van Tuijl, Sjoerd
    van de Vosse, Frans N.
    Rutten, Marcel C. M.
    [J]. BIO-MEDICAL MATERIALS AND ENGINEERING, 2016, 27 (05) : 451 - 460
  • [49] Modified Central Closure Technique for Treatment of Aortic Insufficiency in Patients on Left Ventricular Assist Device Support
    Morgan, Jeffrey A.
    Brewer, Robert J.
    [J]. ASAIO JOURNAL, 2012, 58 (06) : 626 - 628
  • [50] AN IMPLANTABLE LEFT VENTRICULAR-AORTIC ASSIST DEVICE
    FILLER, RM
    BERNHARD, WF
    BANKOLE, M
    LAFARGE, CG
    ROBINSON, T
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1967, 54 (06): : 795 - &