Effect of peritoneal dialysis fluid composition on peritoneal area available for exchange in children

被引:33
|
作者
Fischbach, M
Terzic, J
Chauvé, S
Laugel, V
Muller, A
Haraldsson, B
机构
[1] Pharmacol Univ, Strasbourg, France
[2] Univ Gothenburg, Sahlgrens Univ Hosp, Dept Nephrol, Gothenburg, Sweden
关键词
capillary recruitment; children; intraperitoneal pressure; peritoneal dialysis fluid;
D O I
10.1093/ndt/gfg518
中图分类号
R3 [基础医学]; R4 [临床医学];
学科分类号
1001 ; 1002 ; 100602 ;
摘要
Background. Although conventional peritoneal dialysis fluids (PDFs), such as Dianeal(R), are non-physiological in composition, new PDFs including Physioneal(R) have a more neutral pH, are at least partially buffered with bicarbonate and, most importantly, contain low concentrations of glucose degradation products (GDPs). Methods. To evaluate the impact of new PDFs in childcare, we performed a comparative crossover study with Dianeal(R) and Physioneal(R). We examined both intraperitoneal pressure (IPP), which partly reflects pain induction, and the total pore area available for exchange, which indicates the number of capillaries perfused in the peritoneal membrane at any given moment and therefore partly reflects peritoneal dialysis capacity. The IPP was determined after inflow of 1000 ml/m(2) body surface area (BSA) of dialysate (intraperitoneal volume; IPV). The steady-state unrestricted area over diffusion distance (A(0)/Deltax, in cm(2)/cm per 1.73 m(2) BSA) was calculated from the three-pore theory. Six children were enrolled in the study. On the first day, two consecutive peritoneal equilibration tests of 90 min each were performed using first Dianeal(R) and then Physioneal(R). On the second study day, the procedure was repeated with the fluids given in the opposite order. to IPV (ml/m(2)) Results. The mean IPP normalized was significantly higher for Dianeal(R) (9.5 +/- 0.9 cm/1000 ml/m(2)) than for Physioneal(R) (7.9 +/- 1.2 cm/1000 ml/m(2), P < 0.01). The mean A(0)/Deltax was 17 +/- 4% larger with Dianeal(R) (36095 +/- 2009 cm(2)/cm per 1.73 m(2)) than with Physioneal(R) (31780 2185 cm(2)/cm per 1.73 m(2), p < 0.001; based on 24 data pairs). Conclusions. These pilot study results suggest a higher biocompatibility for Physioneal(R) than for Dianeal(R). Less inflow pain associated with Physioneal(R) induced a lower IPP reflecting enhanced fill volume tolerance, and the lower A(0)/Deltax reflected less capillary recruitment. Taken together, these results suggest that the new more biocompatible PDFs will improve peritoneal dialysis therapy, although this conclusion will require verification in extended clinical trials.
引用
下载
收藏
页码:925 / 932
页数:8
相关论文
共 50 条
  • [21] The effect of peritoneal dialysate on pulmonary function in children on continuous ambulatory peritoneal dialysis
    Ogus, C
    Akman, S
    Cilli, A
    Bahat, E
    Ozdemir, T
    Guven, AG
    DIALYSIS & TRANSPLANTATION, 2004, 33 (02) : 86 - +
  • [22] EFFECT OF PERITONEAL-DIALYSIS FLUID ON VENTILATORY FUNCTION
    EPSTEIN, SW
    INOUYE, T
    ROBSON, M
    OREOPOULOS, DG
    PERITONEAL DIALYSIS BULLETIN, 1982, 2 (03): : 120 - 122
  • [23] Effect of peritoneal dialysis on peritoneal cell biology:: Peritoneal fibroblasts
    Jörres, A
    PERITONEAL DIALYSIS INTERNATIONAL, 1999, 19 : S348 - S352
  • [24] Proteomic analysis of peritoneal fluid of patients treated by peritoneal dialysis: effect of glucose concentration
    Cuccurullo, Manuela
    Evangelista, Ciriana
    Vilasi, Annalisa
    Simeoni, Mariadelina
    Avella, Ferdinando
    Riccio, Eleonora
    Memoli, Bruno
    Malorni, Antonio
    Capasso, Giovambattista
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2011, 26 (06) : 1990 - 1999
  • [25] Effect of increased dialysate volume on peritoneal surface area among peritoneal dialysis patients
    Chagnac, A
    Herskovitz, P
    Ori, Y
    Weinstein, T
    Hirsh, J
    Katz, M
    Gafter, U
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2002, 13 (10): : 2554 - 2559
  • [26] Effect of fluid supplementation and modality on peritoneal permeability characteristics in a rat peritoneal dialysis model
    Zweers, MM
    Splint, LJ
    Krediet, RT
    Struijk, DG
    PERITONEAL DIALYSIS INTERNATIONAL, 2001, 21 (01): : 58 - 64
  • [27] The effect of ligustrazine on peritoneal transport in peritoneal dialysis
    Zhonghua Zhu
    Weiyi Peng
    Yumei Wang
    Hongyan Zhu
    Xiao Yang
    Anguo Deng
    Current Medical Science, 2002, 22 (4) : 334 - 336
  • [28] Peritoneal Fluid Analysis in Peritoneal Dialysis-Associated Peritonitis
    Perl, Jeffrey
    Harel, Ziv
    Nessim, Sharon J.
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2022, 328 (21): : 2157 - 2158
  • [29] PERITONEAL ULTRAFILTRATION AND FLUID REABSORPTION DURING PERITONEAL-DIALYSIS
    LINDHOLM, B
    HEIMBURGER, O
    WANIEWSKI, J
    WERYNSKI, A
    BERGSTROM, J
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 1989, 4 (09) : 805 - 813
  • [30] EFFECT OF INTRODUCTION OF LOW-GLUCOSE-DEGRADATION-PRODUCT PERITONEAL DIALYSIS FLUID ON PERITONEAL DIALYSIS RELATED INFECTIONS
    Lin, D.
    Kam, A.
    Kang, M.
    Kendrick-Jones, J.
    Lam-Po-Tang, M.
    NEPHROLOGY, 2014, 19 : 43 - 43