Cardiac output monitoring with thermodilution pulse-contour analysis vs. non-invasive pulse-contour analysis

被引:14
|
作者
Boisson, M. [1 ]
Poignard, M. E. [1 ]
Pontier, B. [1 ]
Mimoz, O. [2 ]
Debaene, B. [1 ]
Frasca, D. [1 ]
机构
[1] CHU Poitiers, Serv Anesthesie Reanimat, Poitiers, France
[2] CHU Poitiers, Serv Urgences, Poitiers, France
关键词
cardiac ouput; intra-operative monitoring; major surgery LV pressure-volume relations; impact of preload; stroke volume; MAJOR GASTROINTESTINAL SURGERY; CONTINUOUS ARTERIAL-PRESSURE; FLUID RESPONSIVENESS; ABDOMINAL-SURGERY; FINGER CUFF; AGREEMENT; NEXFIN; VALIDATION; THERAPY; TRIAL;
D O I
10.1111/anae.14638
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Intravenous fluid boluses guided by changes in stroke volume improve some outcomes after major surgery, but invasive measurments may limit use. From October 2016 to May 2018, we compared the agreement and trending ability of a photoplethysmographic device (Clearsight) with a PiCCO, calibrated by thermodilution, for haemodynamic variables in 20 adults undergoing major elective surgery. We analysed 4519 measurement pairs, including before and after 68 boluses of 250 ml crystalloid. The bias and precision of stroke volume measurement by Clearsight were -0.89 +/- 4.78 ml compared with the invasive pulse-contour cardiac output device. The coefficient of agreement for stroke volume variation after fluid boluses between the two devices was 0.79 ('strong'). Fluid boluses that increased stroke volume by >= 10% increased mean absolute volume (SD) and mean percentage (SD) stroke volume measurements similarly for the invasive pulse-contour cardiac output and Clearsight devices: 9 (4) ml vs. 8 (4) ml and 16% (8%) vs. 15% (10%), respectively, p > 0.05. The non-invasive Clearsight pulse-contour analysis was similar to an invasive pulse-contour device in measuring absolute and changing stroke volumes during major surgery.
引用
收藏
页码:735 / 740
页数:6
相关论文
共 50 条
  • [41] Pulse contour cardiac output derived from non-invasive arterial pressure in cardiovascular disease
    Bogert, L. W. J.
    Wesseling, K. H.
    Schraa, O.
    Van Lieshout, E. J.
    de Mol, B. A. J. M.
    van Goudoever, J.
    Westerhof, B. E.
    van Lieshout, J. J.
    ANAESTHESIA, 2010, 65 (11) : 1119 - 1125
  • [42] Comparison of Transpulmonary Thermodilution and Calibrated Pulse Contour Analysis with Pulmonary Artery Thermodilution Cardiac Output Measurements in Anesthetized Dogs
    Garofalo, N. A.
    Teixeira-Neto, F. J.
    Rodrigues, J. C.
    Cerejo, S. A.
    Aguiar, A. J. A.
    Becerra-Velasquez, D. R.
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2016, 30 (04) : 941 - 950
  • [43] CORRELATION OF CARDIAC OUTPUT MEASURED BY TRANSPULMONARY THERMODILUTION AND PULSE CONTOUR ANALYSIS IN A EXPERIMENTAL ARDS MODEL.
    Diaz, F.
    Carvajal, C.
    Salomon, T.
    Torres, M.
    Erranz, B.
    Cruces, P.
    Donoso, A.
    CRITICAL CARE MEDICINE, 2008, 36 (12) : A56 - A56
  • [44] Perioperative Fluid Guidance with Transthoracic Echocardiography and Pulse-Contour Device in Morbidly Obese Patients
    Tomi Pösö
    Ola Winsö
    Roman Aroch
    Doris Kesek
    Obesity Surgery, 2014, 24 : 2117 - 2125
  • [45] Semi-invasive measurement of cardiac output based on pulse contour: a review and analysis
    Schloeglhofer, Thomas
    Gilly, Hermann
    Schima, Heinrich
    CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2014, 61 (05): : 452 - 479
  • [46] Predictors of the accuracy of pulse-contour cardiac index and suggestion of a calibration-index: a prospective evaluation and validation study
    Huber, Wolfgang
    Koenig, Jonas
    Mair, Sebastian
    Schuster, Tibor
    Saugel, Bernd
    Eyer, Florian
    Phillip, Veit
    Schultheiss, Caroline
    Thies, Philipp
    Mayr, Ulrich
    Einwaechter, Henrik
    Treiber, Matthias
    Hoellthaler, Josef
    Schmid, Roland M.
    BMC ANESTHESIOLOGY, 2015, 15
  • [47] Erroneous continuous cardiac output by calibrated pulse contour analysis
    Jörn Grensemann
    Frank Wappler
    Samir G. Sakka
    Journal of Clinical Monitoring and Computing, 2013, 27 : 567 - 568
  • [48] Erroneous continuous cardiac output by calibrated pulse contour analysis
    Grensemann, Joern
    Wappler, Frank
    Sakka, Samir G.
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2013, 27 (05) : 567 - 568
  • [49] Continous pulse contour cardiac output measurement vs standard and continous thermodilution technique in cardiac surgery patients
    Rauch, H
    Bottiger, BW
    Muller, M
    Fleischer, F
    Motsch, J
    Martin, E
    ANESTHESIA AND ANALGESIA, 1997, 84 : S122 - S122
  • [50] Hemodynamic monitoring by transpulmonary thermodilution and pulse contour analysis in critically ill children
    Proulx, Francois
    Lemson, Joris
    Choker, Ghassan
    Tibby, Shane M.
    PEDIATRIC CRITICAL CARE MEDICINE, 2011, 12 (04) : 459 - 466