Cardiac output monitoring with thermodilution pulse-contour analysis vs. non-invasive pulse-contour analysis

被引:14
|
作者
Boisson, M. [1 ]
Poignard, M. E. [1 ]
Pontier, B. [1 ]
Mimoz, O. [2 ]
Debaene, B. [1 ]
Frasca, D. [1 ]
机构
[1] CHU Poitiers, Serv Anesthesie Reanimat, Poitiers, France
[2] CHU Poitiers, Serv Urgences, Poitiers, France
关键词
cardiac ouput; intra-operative monitoring; major surgery LV pressure-volume relations; impact of preload; stroke volume; MAJOR GASTROINTESTINAL SURGERY; CONTINUOUS ARTERIAL-PRESSURE; FLUID RESPONSIVENESS; ABDOMINAL-SURGERY; FINGER CUFF; AGREEMENT; NEXFIN; VALIDATION; THERAPY; TRIAL;
D O I
10.1111/anae.14638
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Intravenous fluid boluses guided by changes in stroke volume improve some outcomes after major surgery, but invasive measurments may limit use. From October 2016 to May 2018, we compared the agreement and trending ability of a photoplethysmographic device (Clearsight) with a PiCCO, calibrated by thermodilution, for haemodynamic variables in 20 adults undergoing major elective surgery. We analysed 4519 measurement pairs, including before and after 68 boluses of 250 ml crystalloid. The bias and precision of stroke volume measurement by Clearsight were -0.89 +/- 4.78 ml compared with the invasive pulse-contour cardiac output device. The coefficient of agreement for stroke volume variation after fluid boluses between the two devices was 0.79 ('strong'). Fluid boluses that increased stroke volume by >= 10% increased mean absolute volume (SD) and mean percentage (SD) stroke volume measurements similarly for the invasive pulse-contour cardiac output and Clearsight devices: 9 (4) ml vs. 8 (4) ml and 16% (8%) vs. 15% (10%), respectively, p > 0.05. The non-invasive Clearsight pulse-contour analysis was similar to an invasive pulse-contour device in measuring absolute and changing stroke volumes during major surgery.
引用
收藏
页码:735 / 740
页数:6
相关论文
共 50 条
  • [1] Assessment of continuous cardiac output determination by pulse-contour analysis in septic shock
    Schuerholz, T
    Friedrich, L
    Cobas Meyer, M
    Heine, J
    Sümpelmann, R
    Marx, G
    INTENSIVE CARE MEDICINE, 2002, 28 : S80 - S80
  • [2] Verification of a non-invasive continuous cardiac output measurement method based on the pulse-contour analysis combined with pulse wave transit time
    Yamada, T.
    Sugo, Y.
    Takeda, J.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2010, 27 (01) : 57 - 57
  • [3] AN EVALUATION OF THE PULSE-CONTOUR METHOD OF MEASURING CARDIAC-OUTPUT
    BROCKUTNE, JG
    BLAKE, GTW
    BOSENBERG, AT
    GAFFIN, SL
    HUMPHREY, D
    DOWNING, JW
    SOUTH AFRICAN MEDICAL JOURNAL, 1984, 66 (12): : 451 - 453
  • [4] Pulse-contour analysis: A new method of continuous cardiac output monitoring in pediatric critical care
    Piehl, MD
    Manning, J
    McCurdy, SL
    Rhue, T
    Cairns, B
    PEDIATRIC RESEARCH, 2004, 55 (04) : 60A - 61A
  • [5] Comparison of thermodilution and pulse-contour assessment of cardiac output in patients undergoing MIDCAB-surgery
    Buhre, W
    Weyland, A
    Kazmaier, S
    Baryalei, MM
    Sydow, M
    Sonntag, H
    ANESTHESIOLOGY, 1998, 89 (3A) : U808 - U808
  • [6] Reliability of continuous cardiac output determination by pulse-contour analysis in porcine septic shock
    Schuerholz, T
    Meyer, MC
    Friedrich, L
    Przemeck, M
    Sümpelmann, R
    Marx, G
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2006, 50 (04) : 407 - 413
  • [7] Comparison of cardiac output assessed by pulse-contour analysis and thermodilution in patients undergoing minimally invasive direct coronary artery bypass grafting
    Buhre, G
    Weyland, A
    Kazmaier, S
    Hanekop, GG
    Baryalei, MM
    Sydow, M
    Sonntag, H
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 1999, 13 (04) : 437 - 440
  • [8] EVALUATION OF A NEW PULSE-CONTOUR METHOD FOR EXAMINATION OF CARDIAC OUTPUT
    BERNSTEIN, EF
    EVANS, RL
    CIRCULATION, 1961, 24 (04) : 886 - &
  • [9] Continuous measurement of cardiac output using pulse-contour analysis: truly beat-to-beat?
    Steffen Rex
    Journal of Clinical Monitoring and Computing, 2015, 29 : 319 - 321
  • [10] Comparison of non-calibrated pulse-contour analysis with continuous thermodilution for cardiac output assessment in patients with induced hypothermia after cardiac arrest
    Haenggi, Matthias
    Barthelmes, Daniel
    Ulmer, Hanno
    Takala, Jukka
    Jakob, Stephan M.
    RESUSCITATION, 2011, 82 (04) : 423 - 426