Pattern reversal ERG and VEP -: comparison of stimulation by LED, monitor and a Maxwellian-view system

被引:8
|
作者
Link, B
Rühl, S
Peters, A
Jünemann, A
Horn, FK
机构
[1] Univ Erlangen Nurnberg, Augenklin, Dept Ophthalmol Biometry & Epidemiol, D-91054 Erlangen, Germany
[2] Univ Erlangen Nurnberg, Dept Med Informat Biometry & Epidemiol, D-91054 Erlangen, Germany
关键词
checkerboard reversal; LED; Maxwellian-view system; monitor; PERG; VEP;
D O I
10.1007/s10633-005-5865-z
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: Pattern stimulation is widely used to detect inner retinal dysfunction. In this work we describe a pattern stimulation technique with LEDs and compare the results with conventional methods. Methods: PERG and VEP were derived from three normal subjects. Three different techniques were used to generate a checkerboard pattern reversal stimulus: a 70 Hz monitor, a Maxwellian-view system equipped with a Xenon-arc lamp and a mechanical mirror system, and a LED array (Roland Consult) consisting of 100 white LEDs. Two kinds of luminance (125 and 340 cd/m(2)) and four temporal frequencies (4, 8, 12 and 24 reversals per second) were studied on three healthy subjects. Additionally, a luminance tuning experiment (30, 60, 90, 125 and 340 cd/m(2)) was performed on one subject. Results: Comparison of different stimulation techniques shows reproducible responses of PERG and VEP with all three methods. The LED array leads to slightly smaller amplitudes than both other techniques, which we ascribe to the design of the LED field. No difference of peak times or phases was noticed between different stimulation techniques. A luminance dependency of PERG and VEP is noticeable using stimulation with LED: with decreasing luminance we measured increasing peak times of PERG and VEP and decreasing amplitude of PERG. Conclusion: We conclude that central retinal stimulation with checkerboard pattern reversal is possible with LED. It gives comparable results to monitor and Maxwellian-view system.
引用
收藏
页码:1 / 11
页数:11
相关论文
共 26 条
  • [21] PATTERN REVERSAL VEPS BY TV AND MIRROR MOVEMENT STIMULATION - A METHODOLOGICAL COMPARISON
    不详
    ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1984, 57 (02): : P23 - P23
  • [22] COMPARISON OF VEPS ELICITED WITH PATTERN REVERSAL AND LIGHT-EMITTING DIODE STIMULATION
    NORCROSS, K
    ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1984, 58 (02): : P49 - P49
  • [23] Comparison of the reliability of multifocal visual evoked cortical potentials generated by pattern reversal and pattern pulse stimulation
    Souza, G. S.
    Schakelford, H. B.
    Moura, A. L. A.
    Gomes, B. D.
    Ventura, D. F.
    Fitzgerald, M. E. C.
    Silveira, L. C. L.
    BRAZILIAN JOURNAL OF MEDICAL AND BIOLOGICAL RESEARCH, 2012, 45 (10) : 955 - 961
  • [24] PATTERN ONSET, OFFSET AND REVERSAL - A COMPARISON OF RESPONSE DISTRIBUTION FOLLOWING HALF-FIELD STIMULATION
    KRISS, A
    HALLIDAY, AM
    ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1980, 49 (5-6): : P101 - P101
  • [25] True pattern-reversal LED stimulator and its comparison to LCD and CRT displays: visual evoked potential study
    Voda, P.
    Kremlacek, J.
    Kordek, D.
    Chutna, M.
    Bezrouk, A.
    SCIENTIFIC REPORTS, 2024, 14 (01)
  • [26] True pattern-reversal LED stimulator and its comparison to LCD and CRT displays: visual evoked potential study
    P. Voda
    J. Kremláček
    D. Kordek
    M. Chutná
    A. Bezrouk
    Scientific Reports, 14