Pattern reversal ERG and VEP -: comparison of stimulation by LED, monitor and a Maxwellian-view system

被引:8
|
作者
Link, B
Rühl, S
Peters, A
Jünemann, A
Horn, FK
机构
[1] Univ Erlangen Nurnberg, Augenklin, Dept Ophthalmol Biometry & Epidemiol, D-91054 Erlangen, Germany
[2] Univ Erlangen Nurnberg, Dept Med Informat Biometry & Epidemiol, D-91054 Erlangen, Germany
关键词
checkerboard reversal; LED; Maxwellian-view system; monitor; PERG; VEP;
D O I
10.1007/s10633-005-5865-z
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: Pattern stimulation is widely used to detect inner retinal dysfunction. In this work we describe a pattern stimulation technique with LEDs and compare the results with conventional methods. Methods: PERG and VEP were derived from three normal subjects. Three different techniques were used to generate a checkerboard pattern reversal stimulus: a 70 Hz monitor, a Maxwellian-view system equipped with a Xenon-arc lamp and a mechanical mirror system, and a LED array (Roland Consult) consisting of 100 white LEDs. Two kinds of luminance (125 and 340 cd/m(2)) and four temporal frequencies (4, 8, 12 and 24 reversals per second) were studied on three healthy subjects. Additionally, a luminance tuning experiment (30, 60, 90, 125 and 340 cd/m(2)) was performed on one subject. Results: Comparison of different stimulation techniques shows reproducible responses of PERG and VEP with all three methods. The LED array leads to slightly smaller amplitudes than both other techniques, which we ascribe to the design of the LED field. No difference of peak times or phases was noticed between different stimulation techniques. A luminance dependency of PERG and VEP is noticeable using stimulation with LED: with decreasing luminance we measured increasing peak times of PERG and VEP and decreasing amplitude of PERG. Conclusion: We conclude that central retinal stimulation with checkerboard pattern reversal is possible with LED. It gives comparable results to monitor and Maxwellian-view system.
引用
收藏
页码:1 / 11
页数:11
相关论文
共 26 条
  • [1] Pattern reversal ERG and VEP - Comparison of stimulation by LED, monitor and a Maxwellian-view system
    Link, B
    Ruehl, S
    Peters, A
    Juenemann, A
    Horn, FK
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [2] Pattern Reversal ERG and VEP – Comparison of Stimulation by LED, Monitor and a Maxwellian-view System
    Barbara Link
    Sylvia Rühl
    Andrea Peters
    Anselm Jünemann
    Folkert K. Horn
    Documenta Ophthalmologica, 2006, 112 : 1 - 11
  • [3] PATTERN REVERSAL VEP AND ERG - SIMULTANEOUS RECORDINGS
    BASCIANI, M
    TREVISO, M
    GAMBI, D
    ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1985, 61 (03): : S134 - S135
  • [4] PATTERN REVERSAL VEP - A COMPARISON OF THE TV AND OPTOMECHANICAL STIMULATION
    LOWITZSCH, K
    FLICKINGER, U
    KEMPKES, K
    MANDERY, G
    EEG-EMG-ZEITSCHRIFT FUR ELEKTROENZEPHALOGRAPHIE ELEKTROMYOGRAPHIE UND VERWANDTE GEBIETE, 1983, 14 (01): : 43 - 46
  • [5] Pattern reversal ERG with LED-stimulation using cyclic summation technique
    Link, B
    Jünemann, A
    Horn, FK
    DOCUMENTA OPHTHALMOLOGICA, 2006, 112 (01) : 53 - 60
  • [6] Pattern Reversal ERG with LED-stimulation Using Cyclic Summation Technique*
    Barbara Link
    Anselm Jünemann
    Folkert K. Horn
    Documenta Ophthalmologica, 2006, 112 : 53 - 60
  • [7] Electroretinography in thyroid eye disease: comparison of the pattern ERG and the pattern VEP
    Johnson, Brooke
    Park, Jason C.
    MacIntosh, Peter
    McAnany, J. Jason
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [8] A PORTABLE VEP ERG STIMULATION AND RECORDING-SYSTEM
    REITS, D
    SPORTEL, H
    SPEKREIJSE, H
    ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1985, 61 (03): : S246 - S246
  • [9] THE MATURATION OF THE PATTERN REVERSAL VEP AND FLASH ERG IN PRE-TERM INFANTS
    GROSE, J
    HARDING, GFA
    WILTON, AY
    BISSENDEN, JG
    CLINICAL VISION SCIENCES, 1989, 4 (03): : 239 - 246
  • [10] PATTERN-REVERSAL VEP AND ERG IN THE EARLY DIAGNOSIS OF GLAUCOMA CHRONICUM SIMPLEX
    LOWITZSCH, K
    WELT, R
    EEG-EMG-ZEITSCHRIFT FUR ELEKTROENZEPHALOGRAPHIE ELEKTROMYOGRAPHIE UND VERWANDTE GEBIETE, 1991, 22 (04): : 217 - 223