Fractionation of chlorinated and brominated persistent organic pollutants in several food samples by pyrenyl-silica liquid chromatography prior to GC-MS determination

被引:14
|
作者
Gómara, B
García-Ruiz, C
González, MJ
Marina, ML
机构
[1] Univ Alcala de Henares, Dept Quim Analit, Fac Quim, Alcala De Henares 28871, Madrid, Spain
[2] CSIC, Dept Anal Instrumental & Quim Ambiental, Inst Quim Organ Gen, E-28006 Madrid, Spain
关键词
brominated and chlorinated POPs; fractionation; PYE; HPLC;
D O I
10.1016/j.aca.2006.02.053
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A high-performance liquid chromatography (HPLC) method using a column of 2-(1-pyrenyl)ethyldimethylsilylated silica was developed in this work in order to achieve satisfactory and reproducible fractionation of polychlorinated biphenyls (PCBs) from brominated flame retardants (BFRs) (polybrominated diphenylethers, PBDEs; and polybrominated biphenyls, PBBs). After the study of different chromatographic parameters (mobile phase composition and separation temperature were the most important) an isocratic elution with isooctane: toluene (98:2, v/v) at a flow-rate of 1 mL/min, a temperature of 45 degrees C, and UV-detection at 225 nm was selected for fractionation of PCBs (time region, 4.0-5.8 min) from PBDEs (5.8-9.0 min) and from PBBs (5.8-11.0 min). The applicability of this method to food samples was demonstrated by fractionating PCBs from PBDEs in three food samples (cheese, milk, and fish). Interferences from PCBs (present in real samples at much higher concentrations than PBDEs) were removed in this way. In addition, by analysing these samples by gas chromatography-mass spectrometry (GC-MS) with and without previous fractionation we were able to observe an improvement in detection sensitivity for PBDEs after HPLC fractionation. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:208 / 213
页数:6
相关论文
共 25 条
  • [21] Determination of polychlorinated dibenzo-p-dioxins and furans in food samples by gas chromatography-triple quadrupole mass spectrometry (GC-MS/MS) and comparison with gas chromatography-high resolution mass spectrometry (GC-HRMS)
    Lyu, Bing
    Zhang, Xiaoyan
    Li, Jingguang
    Zhang, Lei
    Zhong, Yuxin
    Wu, Yongning
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2023, 115
  • [22] Experimental design of switchable solvent-based liquid phase microextraction for the accurate determination of etrimfos from water and food samples at trace levels by GC-MS
    Firat, Merve
    Chormey, Dotse Selali
    Bakirdere, Sezgin
    Turak, Fatma
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2019, 191 (10)
  • [23] Development of a stir bar sorptive extraction and thermal desorption-gas chromatography-mass spectrometry method for the simultaneous determination of several persistent organic pollutants in water samples
    Prieto, A.
    Zuloaga, O.
    Usobiaga, A.
    Etxebarria, N.
    Fernandez, L. A.
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1174 (1-2) : 40 - 49
  • [24] Cellulose Paper Sorptive Extraction (CPSE) Combined with Gas Chromatography-Mass Spectrometry (GC-MS) for Facile Determination of Lorazepam Residues in Food Samples Involved in Drug Facilitated Crimes
    Jain, Bharti
    Jain, Rajeev
    Kabir, Abuzar
    Ghosh, Abhishek
    Zughaibi, Torki
    Chauhan, Vimukti
    Koundal, Sonali
    Sharma, Shweta
    SEPARATIONS, 2023, 10 (05)
  • [25] Needle-Trap Device (NTD) Packed with Reduced Graphene Oxide (rGO) for Sample Preparation Prior to the Determination of Polycyclic Aromatic Hydrocarbons (PAHs) from Aqueous Samples by Gas Chromatography-Mass spectrometry (GC-MS)
    Kedziora-Koch, Kamila
    Rykowska, Iwona
    Wasiak, Wieslaw
    ANALYTICAL LETTERS, 2019, 52 (11) : 1681 - 1698