Development of a new semi-quantitative non-invasive method for evaluating ventricular stroke work

被引:2
|
作者
Cheng, Mu-Hua [1 ]
Rao, Guo-Hui [2 ]
Zhou, Han-Jian [3 ]
Xu, Jie-Hua [1 ]
Zhang, Feng [1 ]
机构
[1] Sun Yat Sen Univ, Hosp Affiliated 3, Dept Nucl Med, Guangzhou 510630, Guangdong, Peoples R China
[2] Sun Yat Sen Univ, Affiliated Hosp 1, Dept Nucl Med, Guangzhou 510630, Guangdong, Peoples R China
[3] Sun Yat Sen Univ, Hosp Affiliated 3, Dept Cardiovasol, Guangzhou 510630, Guangdong, Peoples R China
关键词
gated blood pool imaging; hydrodynamics; stroke volume; stroke work; ventricular function; GATED SPECT; ARTERIAL; VOLUME; DYSFUNCTION;
D O I
10.1111/j.1475-097X.2008.00841.x
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Ventricular stroke work (SW) is one of the best indices to evaluate ventricular function, however, the SW monitoring mainly depends on the invasive method with the artery catheter. In this paper, our aim is to develop a new semi-quantitative non-invasive method for evaluating ventricular SW. The multiple gated cardiac blood pool imaging was done in 25 patients with coronary artery disease and 12 normal controls. A new parameter, the relative stroke work (RSW) of left ventricle, was calculated using an equation derived from the principle of hydrodynamics. The left ventricular SW was analyzed by stroke volume (SV) and mean arterial pressure. Ejected fraction (EF), peak ejected rate (PER) and peak filling rate (PFR) were gotten with the routine software in imaging device. The left ventricular RSW was linearly correlated with the SW. The RSW was related to the SV, EF, PER and PFR of the left ventricle. The RSW had regressive relation with SV and PER. The RSW in patients, same as SW, SV, EF, PFR and PER, was noticeably lower than that in normal controls, P < 0.01. The RSW is a potential and valuable clinical index for evaluation of the ventricular function.
引用
收藏
页码:95 / 99
页数:5
相关论文
共 50 条
  • [41] Quantitative assessment of left ventricular myocardial work in chronic kidney disease patients by a novel non-invasive pressure-strain loop analysis method
    Liu, Feng-Zhen
    Wang, Xiao-Lin
    Zhang, Chun-Quan
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2021, 37 (05): : 1567 - 1575
  • [42] Non-invasive assessment of stroke work using cardiac magnetic resonance imaging
    Matthews, Gareth
    Grafton-Clarke, Ciaran
    Swift, Andy J.
    Ryding, Alisdair
    Assadi, Hosam
    Garg, Pankaj
    Li, Rui
    Mehmood, Zia
    Sawh, Chris
    Gosling, Rebecca
    Alabed, Samer
    HEART, 2023, 109 : A200 - A201
  • [43] The non-invasive echocardiographic assessment of right ventricular myocardial work in a healthy population
    Wu, Jian
    Huang, Xinyi
    Huang, Kunhui
    Gao, Qiumei
    Chen, Xu
    Tian, Yuan
    Tang, Yiruo
    Lin, Biqin
    Su, Maolong
    ACTA CARDIOLOGICA, 2023, 78 (04) : 423 - 432
  • [44] PHONOANGIOGRAPHY - NON-INVASIVE DIAGNOSTIC METHOD FOR EVALUATING ARTERIAL-STENOSIS
    GRUBER, J
    DUNCAN, G
    DEWEY, CF
    MYERS, GS
    LEES, RS
    AMERICAN JOURNAL OF CARDIOLOGY, 1975, 35 (01): : 141 - 141
  • [45] In-vivo validation of a new non-invasive continuous ventricular stroke volume monitoring system in an animal model
    Konings, Maurits K.
    Grundeman, Paul F.
    Goovaerts, Henk G.
    Roosendaal, Maarten R.
    Hoefer, Imo E.
    Doevendans, Pieter A.
    Rademakers, Frank E.
    Buhre, Wolfgang F.
    CRITICAL CARE, 2011, 15 (04):
  • [46] NEW NON-INVASIVE METHOD FOR QUANTIFICATION OF GASTRIC CONTRACTILITY
    AKKERMANS, LMA
    JACOBS, F
    HONGYOE, O
    ROELOFS, JMM
    WITTEBOL, P
    WIENER KLINISCHE WOCHENSCHRIFT, 1980, 92 (15) : 551 - 551
  • [47] New Non-Invasive Method for the Authentication of Apple Cultivars
    Barberis, Elettra
    Amede, Elia
    Dondero, Francesco
    Marengo, Emilio
    Manfredi, Marcello
    FOODS, 2022, 11 (01)
  • [48] A NEW NON-INVASIVE METHOD FOR EVALUATION OF VENOUS HEMODYNAMICS
    WIENERT, V
    BLAZEK, V
    HAUTARZT, 1982, 33 (09): : 498 - 499
  • [49] A new method for non-invasive intracranial pressure monitoring
    Russell, D
    Paulat, K
    Maur, UM
    Brucher, R
    STROKE, 2004, 35 (06) : E231 - E231
  • [50] A new simple non-invasive method for flow measurement
    Zhu, HL