Development of a new semi-quantitative non-invasive method for evaluating ventricular stroke work

被引:2
|
作者
Cheng, Mu-Hua [1 ]
Rao, Guo-Hui [2 ]
Zhou, Han-Jian [3 ]
Xu, Jie-Hua [1 ]
Zhang, Feng [1 ]
机构
[1] Sun Yat Sen Univ, Hosp Affiliated 3, Dept Nucl Med, Guangzhou 510630, Guangdong, Peoples R China
[2] Sun Yat Sen Univ, Affiliated Hosp 1, Dept Nucl Med, Guangzhou 510630, Guangdong, Peoples R China
[3] Sun Yat Sen Univ, Hosp Affiliated 3, Dept Cardiovasol, Guangzhou 510630, Guangdong, Peoples R China
关键词
gated blood pool imaging; hydrodynamics; stroke volume; stroke work; ventricular function; GATED SPECT; ARTERIAL; VOLUME; DYSFUNCTION;
D O I
10.1111/j.1475-097X.2008.00841.x
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Ventricular stroke work (SW) is one of the best indices to evaluate ventricular function, however, the SW monitoring mainly depends on the invasive method with the artery catheter. In this paper, our aim is to develop a new semi-quantitative non-invasive method for evaluating ventricular SW. The multiple gated cardiac blood pool imaging was done in 25 patients with coronary artery disease and 12 normal controls. A new parameter, the relative stroke work (RSW) of left ventricle, was calculated using an equation derived from the principle of hydrodynamics. The left ventricular SW was analyzed by stroke volume (SV) and mean arterial pressure. Ejected fraction (EF), peak ejected rate (PER) and peak filling rate (PFR) were gotten with the routine software in imaging device. The left ventricular RSW was linearly correlated with the SW. The RSW was related to the SV, EF, PER and PFR of the left ventricle. The RSW had regressive relation with SV and PER. The RSW in patients, same as SW, SV, EF, PFR and PER, was noticeably lower than that in normal controls, P < 0.01. The RSW is a potential and valuable clinical index for evaluation of the ventricular function.
引用
收藏
页码:95 / 99
页数:5
相关论文
共 50 条
  • [1] NON-INVASIVE SEMI-QUANTITATIVE AND QUANTITATIVE ULTRASONOGRAPHY FINDINGS IN KNEE OSTEOARTHRITIS: PRELIMINARY STUDY
    Podlipska, J.
    Koski, J. M.
    Liukkonen, E.
    Tervonen, O.
    Arokoski, J.
    Saarakkala, S.
    OSTEOARTHRITIS AND CARTILAGE, 2014, 22 : S278 - S279
  • [2] Investigation of the new non-invasive semi-quantitative method of 123I-IMP pediatric cerebral perfusion SPECT
    Wakabayashi, Yasuharu
    Uchiyama, Mayuki
    Daisaki, Hiromitsu
    Matsumoto, Makoto
    Sakamoto, Masafumi
    Kashikura, Kenichi
    PLOS ONE, 2020, 15 (11):
  • [3] Establishment of a Non-Invasive Semi-Quantitative Bioluminescent Imaging Method for Monitoring of an Orthotopic Esophageal Cancer Mouse Model
    Kuroda, Shinji
    Kubota, Tetsushi
    Aoyama, Katsuyuki
    Kikuchi, Satoru
    Tazawa, Hiroshi
    Nishizaki, Masahiko
    Kagawa, Shunsuke
    Fujiwara, Toshiyoshi
    PLOS ONE, 2014, 9 (12):
  • [4] Right ventricular myocardial work: new method for non-invasive assessment of right ventricular function in HFrEF
    Butcher, S. C.
    Fortuni, F.
    Montero, J. M.
    Marsan, N. Ajmone
    Delgado, V
    Bax, J. J.
    EUROPEAN HEART JOURNAL, 2020, 41 : 1017 - 1017
  • [5] DEVELOPMENT OF A SEMI-QUANTITATIVE MIBG REPORTING METHOD
    Lewington, Val
    Bar-Sever, Zvi
    Lynch, Tom
    McEwan, Alexander J. B.
    Giammarile, Francesco
    Staudenherz, Anton
    Shulkin, Barry L.
    Ladenstein, Ruth
    PEDIATRIC BLOOD & CANCER, 2009, 53 (05) : 808 - 808
  • [6] NON-INVASIVE SEMI-QUANTITATIVE MEASUREMENTS OF TIDAL PRESSURE-VOLUME AND FLOW RELATIONS OF LUNG IN COPD PATIENTS
    MOAVERO, NE
    LIPTON, DS
    JENOURI, GA
    PINE, J
    SCHNEIDER, A
    SACKNER, MA
    BULLETIN EUROPEEN DE PHYSIOPATHOLOGIE RESPIRATOIRE-CLINICAL RESPIRATORY PHYSIOLOGY, 1984, 20 (04): : 333 - 339
  • [7] Non-invasive approach and semi-quantitative evaluation of mitral regurgitation by Cine-MRI, transthoracic and transoesophageal echography
    Wolff, F
    Koenig, A
    Baruthio, J
    Armspach, JP
    Chambron, J
    Grucker, D
    COMPUTERS IN CARDIOLOGY 1997, VOL 24, 1997, 24 : 161 - 163
  • [8] A new electric method for non-invasive continuous monitoring of stroke volume and ventricular volume-time curves
    Konings, Maurits K.
    Goovaerts, Henk G.
    Roosendaal, Maarten R.
    Rienks, Rienk
    Koevoets, Ferry M.
    Bleys, Ronald L.
    Buhre, Wolfgang F.
    Dorresteijn, Paul M.
    Hesselink, Tim
    Officier, Arthur E.
    Hollenkamp, Charles L.
    Rademakers, Frank E.
    BIOMEDICAL ENGINEERING ONLINE, 2012, 11
  • [9] A new electric method for non-invasive continuous monitoring of stroke volume and ventricular volume-time curves
    Maurits K Konings
    Henk G Goovaerts
    Maarten R Roosendaal
    Rienk Rienks
    Ferry M Koevoets
    Ronald L Bleys
    Wolfgang F Buhre
    Paul M Dorresteijn
    Tim Hesselink
    Arthur E Officier
    Charles L Hollenkamp
    Frank E Rademakers
    BioMedical Engineering OnLine, 11
  • [10] Investigation of the new non-invasive semi-quantitative method of 123I-IMP pediatric cerebral perfusion SPECT (vol 15, e0241987, 2020)
    Wakabayashi, Yasuharu
    Uchiyama, Mayuki
    Daisaki, Hiromitsu
    Matsumoto, Makoto
    Sakamoto, Masafumi
    Kashikura, Kenichi
    PLOS ONE, 2024, 19 (04):