Transfemoral transcatheter aortic valve replacement without contrast medium using the Medtronic CoreValve system: a single center experience

被引:7
|
作者
Maffeo, Diego [1 ]
Bettari, Luca [1 ]
Latib, Azeem [2 ,3 ]
Maiandi, Cristian [1 ]
Villa, Emmanuel [4 ]
Messina, Antonio [4 ]
Saccocci, Matteo [4 ]
Arneri, Andrea [5 ]
Cuccia, Claudio [1 ]
Troise, Giovanni [4 ]
机构
[1] Fdn Poliambulanza Ist Osped, Dept Cardiol, Brescia, Italy
[2] Univ Vita Salute San Raffaele, IRCCS San Raffaele Hosp, EMO GVM Ctr Cuore Columbus, Milan, Italy
[3] Montefiore Med Ctr, Dept Cardiol, New York, NY USA
[4] Fdn Poliambulanza Ist Osped, Dept Cardiothorac Surg, Via Teonida Bissolati 57, I-25124 Brescia, Italy
[5] Medtron Italia, Coronary & Struct Heart, Milan, Italy
来源
JOURNAL OF CARDIOVASCULAR SURGERY | 2020年 / 61卷 / 04期
关键词
Aortic valve; Aortic valve stenosis; Transcatheter aortic valve replacement; Renal insufficiency; chronic; Acute kidney injury; ACUTE KIDNEY INJURY; IMPLANTATION INCIDENCE; COMPUTED-TOMOGRAPHY; PREDICTIVE FACTORS; RENAL-FUNCTION; ZERO CONTRAST; RISK; ASSOCIATION; OUTCOMES; DISEASE;
D O I
10.23736/S0021-9509.20.11083-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Transcatheter aortic valve replacement (TAVR) in patients with chronic kidney disease (CKD) is challenging due to the high risk of contrast-induced nephropathy (CIN) and acute kidney injury (AKI). AKI dramatically reduces the clinical benefit of TAVR and is one of the strongest predictors of 30-day mortality as well as long-term adverse outcomes after TAVR. The aim of this study was to evaluate a protocol specifically designed to reduce the incidence of contrast-induced nephropathy (CIN) in advanced CKD patients screened for and undergoing TAVR. METHODS: Twelve consecutive patients with severe aortic valve stenosis suffering from at least stage 4 CKD underwent both screening with pre-procedural computed tomography scan (CT scan) and bioprosthetic valve implantation without contrast medium. All the TAVR procedures were performed using the CoreValve Evolut R/PRO transcatheter aortic valve (Medtronic Inc, Minneapolis, MN, USA). The annulus and the optimal implantation projection were identified on the non-contrast medium CT scans with the aid of calcifications as a reference. The implant projection was confirmed immediately before the valve implantation by placing two pigtail catheters alternately inside each sinus of Valsalva (SOV). RESULTS: We enrolled 12 patients: mean age 83.42 4.50 years, number of male 5 (41.7%), mean STS 10.33 +/- 6.16, mean EuroScore II 13.75 +/- 9.07, mean serum creatinine 2.01 +/- 0.63 mg/dL, mean eGFR 23.00 +/- 5.69 mL/min/1.7m(2). All TAVR procedures were successful, leading to a drop in transaortic mean gradient (mean gradient 33.5 +/- 14.09 mmHg; postoperative mean gradient 6.08 +/- mmHg). No patient had more than a mild paravalvular leak. Only two patients underwent permanent pacemaker implantation due to advanced atrioventricular block (AV block). Mean change in eGFR 48 hours after the procedure was 1.3 mL/min. None of the patients developed AKI, according to Valve Academic Research Consortium-2 (VARC-2) definition. CONCLUSIONS: In patients with advanced CKD, a strategy of "zero contrast" TAVR, preceded by accurate CT scan analysis and procedural planning, appears to be safe and feasible permitting to preserve renal function. The avoidance of contrast medium during preprocedural analysis and TAVR implantation could reduce the incidence of AKI and consequently could improve outcomes in this complex patient cohort.
引用
收藏
页码:489 / 495
页数:7
相关论文
共 50 条
  • [31] Combining the CoreValve Evolut PRO and 14-French eSheath in transfemoral transcatheter aortic valve replacement
    Masaki Yashige
    Kan Zen
    Yoshito Kadoya
    Satoaki Matoba
    Cardiovascular Intervention and Therapeutics, 2021, 36 : 266 - 267
  • [32] Reduction in Radiation and Contrast Dose in Transcatheter Aortic Valve Replacement Over Time: A Single-Center Experience
    Alrifai, Abdulah
    Grajeda, Edwin
    Ramos, Fergie
    Kabach, Mohamad
    Pino, Jesus
    Sundaravel, Swethika
    Dayanand, Pradeep
    Venegas, Eduardo
    Lovitz, Lawrence
    Rothenberg, Mark
    Cubeddu, Roberto
    Daniel, George
    Heller, Eric
    Faber, Cristiano
    Chait, Robert
    Nores, Marcos
    JACC-CARDIOVASCULAR INTERVENTIONS, 2018, 11 (04) : S50 - S51
  • [33] Combining the CoreValve Evolut PRO and 14-French eSheath in transfemoral transcatheter aortic valve replacement
    Yashige, Masaki
    Zen, Kan
    Kadoya, Yoshito
    Matoba, Satoaki
    CARDIOVASCULAR INTERVENTION AND THERAPEUTICS, 2021, 36 (02) : 266 - 267
  • [34] Transcatheter aortic valve replacement in atypical valve anatomy using the Lotus valve A Chinese single-center experience
    Xu, Q.
    Liu, X.
    Jiang, J.
    He, Y.
    Zhu, Q.
    Gao, F.
    Du, F.
    He, W.
    Cheng, J.
    Kong, M.
    Pu, Z.
    Zhou, Q.
    Gooley, R.
    Wang, J.
    HERZ, 2021, 46 (01) : 63 - 70
  • [35] Transcatheter aortic valve replacement in patients with quadricuspid aortic valve in a single center
    Liu, Yang
    Zhai, Mengen
    Mao, Yu
    Xu, Chennian
    Ma, Yanyan
    Li, Lanlan
    Jin, Ping
    Yang, Jian
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [36] Immediate and mid-term results of transfemoral aortic valve implantation using either the Edwards Sapien™ transcatheter heart valve or the Medtronic CoreValve® System in high-risk patients with aortic stenosis
    Attias, David
    Himbert, Dominique
    Ducrocq, Gregory
    Detaint, Delphine
    Al-Attar, Nawwar
    Iung, Bernard
    Francis, Fady
    Maury, Jean-Michel
    Brochet, Eric
    Enguerrand, Daniel
    Nataf, Patrick
    Vahanian, Alec
    ARCHIVES OF CARDIOVASCULAR DISEASES, 2010, 103 (04) : 236 - 245
  • [37] Correlates on MSCT of Paravalvular Aortic Regurgitation After Transcatheter Aortic Valve Implantation Using the Medtronic CoreValve Prosthesis
    Schultz, Carl J.
    Tzikas, Apostolos
    Moelker, Adriaan
    Rossi, Alexia
    Nuis, Rutger-Jan
    Geleijnse, Marcel M.
    van Mieghem, Nicolas
    Krestin, Gabriel P.
    de Feyter, Pim
    Serruys, Patrick W.
    de Jaegere, Peter P.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2011, 78 (03) : 446 - 455
  • [38] Transcatheter Aortic Valve Replacement Without the Use of Contrast Medium: An Alternative Safe Implantation Technique
    Owais, Tamer
    El Garhy, Mohammad
    Fuchs, Juergen
    Schreiber, Mathias
    Girdauskas, Evaldas
    Kuntze, Thomas
    JOURNAL OF INVASIVE CARDIOLOGY, 2020, 32 (09): : 330 - 334
  • [39] Zero Contrast Transfemoral Transcatheter Aortic Valve Replacement Using Fluoroscopy-Echocardiography Fusion Imaging
    Eskandari, Mehdi
    Aldalati, Omar
    Byrne, Jonathan
    Dworakowski, Rafal
    Wendler, Olaf
    Alcock, Ema
    Monaghan, Mark
    MacCarthy, Philip
    AMERICAN JOURNAL OF CARDIOLOGY, 2016, 117 (11): : 1861 - 1862
  • [40] Sutureless aortic valve replacement vs. transcatheter aortic valve implantation: a review of a single center experience
    Santarpino, Giuseppe
    Gregorini, Renato
    Specchia, Luigi
    Albano, Antonio
    Nicoletti, Anna
    Fischlein, Theodor
    MINERVA CARDIOANGIOLOGICA, 2018, 66 (02): : 160 - 162