Assessment of cerebral autoregulation using time-domain cross-correlation analysis

被引:25
|
作者
Chiu, CC [1 ]
Yeh, SJ [1 ]
机构
[1] Feng Chia Univ, Inst Automat Control Engn, Taichung 40724, Taiwan
关键词
cross-correlation analysis; mean arterial blood pressure; mean cerebral blood flow velocity; cerebral autoregulation;
D O I
10.1016/S0010-4825(01)00015-4
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Time domain cross-correlation analysis of pre-filtered mean arterial blood pressure (MABP) and mean cerebral blood flow velocity (MCBFV) was applied to assess the cerebral autoregulation (CA). Beat-to-beat time series of spontaneous arterial blood pressure and cerebral blood flow velocity were obtained from 13 young normal volunteers with the Finapres device and the transcranial Doppler for periods of approximately 5 min in the supine position. Cross-correlation functions (CCFs) were estimated using a 64 beat wide moving window. Mean CCF patterns were obtained for each subject and for the entire population. The MABP and MCBFV signals were bandpass filtered in the very low-frequency range (VLF, 0.015-0.07 Hz), low-frequency range (LF, 0.07-0.15 Hz) and high-frequency range (HF, 0.15-0.40 Hz) before applying CCF for the purpose of studying the effect of different bandwidths on the resulting mean CCFs. Results revealed that the corresponding time lags of the peak values of the MABP-MCBFV CCFs increased significantly between the LF and BY frequency ranges (LF: -1.20 +/- 0.91 s, HF: -0.07 +/- 0.42 s, p < 0.001; paired sign test). The left-shift (negative lag) of the CCF peak between MABP and MCBFV is a result of the phase-lead property. The increasing time lag of the CCF peak indicated evidence of the autoregulatory disturbance. The CCF of pre-filtered spontaneous MABP and MCBFV could be a useful tool to estimate the CA dynamic response. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:471 / 480
页数:10
相关论文
共 50 条
  • [1] Continuous cerebral autoregulation monitoring by cross-correlation analysis
    Steinmeier, R
    Hofmann, RP
    Bauhuf, C
    Hübner, U
    Fahlbusch, R
    [J]. JOURNAL OF NEUROTRAUMA, 2002, 19 (10) : 1127 - 1138
  • [2] Time-Domain Far-Field Measurements for Cross-Correlation Analysis
    Kuznetsov, Y.
    Baev, A.
    Haider, M.
    Russer, J. A.
    Russer, P.
    [J]. 2017 INTERNATIONAL CONFERENCE ON ELECTROMAGNETICS IN ADVANCED APPLICATIONS (ICEAA), 2017, : 1517 - 1520
  • [3] Assessment of Cerebral Autoregulation Using Cross-Correlation Functions in Different Antihypertensive Drug Treatments
    Liau, Ben-Yi
    Chiu, Chuang-Chien
    Yeh, Shoou-Jeng
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 983 - +
  • [4] TIME-DOMAIN ANALYSIS OF CROSS-CORRELATION FOR TIME-DELAY ESTIMATION WITH AN AUTOCORRELATED SIGNAL
    KUMAR, A
    BARSHALOM, Y
    [J]. IEEE TRANSACTIONS ON SIGNAL PROCESSING, 1993, 41 (04) : 1664 - 1668
  • [5] Assessment of Dynamic Cerebral Autoregulation Using Spectral and Cross-correlation Analyses of Different Antihypertensive Drug Treatments
    Liau, Ben-Yi
    Chiu, Chuang-Chien
    Yeh, Shoou-Jeng
    [J]. JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2010, 30 (03) : 169 - 176
  • [6] Continuous cerebral autoregulation monitoring by cross-correlation analysis:: Evaluation in healthy volunteers
    Steinmeier, R
    Bauhuf, C
    Hübner, U
    Hofmann, RP
    Fahlbusch, R
    [J]. CRITICAL CARE MEDICINE, 2002, 30 (09) : 1969 - 1975
  • [7] IMPLEMENTATION OF ULTRASOUND TIME-DOMAIN CROSS-CORRELATION BLOOD VELOCITY ESTIMATORS
    JENSEN, JA
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1993, 40 (05) : 468 - 474
  • [8] STATIONARY ECHO CANCELING IN VELOCITY ESTIMATION BY TIME-DOMAIN CROSS-CORRELATION
    JENSEN, JA
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1993, 12 (03) : 471 - 477
  • [9] A ScanSAR Processing without Azimuth Stitching by Time-domain Cross-correlation
    Won, Joong-Sun
    [J]. KOREAN JOURNAL OF REMOTE SENSING, 2022, 38 (03) : 251 - 263
  • [10] Variability of time-domain indices of dynamic cerebral autoregulation
    Panerai, RB